Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 28 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
57. Q201FR (C– E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
58. C212
S/C 264
V
4 s
0
Immediately R229 smoked for 2 sec and
opened. Potection circuit(RLY301) operated.
NB. No hazard
opened. Potection circuit(RLY301) operated.
NB. No hazard
59. Stand-
by transformer (pin t
o pin)
by transformer (pin t
o pin)
S/C 264
V 1 h, 40 min
0.04
mmediately protection circuit(RLY301)
operated. Primary winding of Standby
transformer heated up to 93,5 K and
stabilized. NCD. No. hazard
operated. Primary winding of Standby
transformer heated up to 93,5 K and
stabilized. NCD. No. hazard
60. Right speaker te
rminal (1/8 Pmax)
rminal (1/8 Pmax)
S/C 264
V
3 s
0
Immediately protection circuit (RLY301) op
erated. NCD. No hazard.
erated. NCD. No hazard.
61. closed
ventilation (1/8
Pmax)
ventilation (1/8
Pmax)
- 264
V
3 h, 22 min
0.20
Primary winding of main transformer heated
up to 118,2 K and stabilized. NCD. No hazard.
up to 118,2 K and stabilized. NCD. No hazard.
62. Pmax (5
channels)
channels)
- 264
V
32 min
0
Primary winding of main transformer heated
up to 120,3 K and thermal fuse opened. NB.
No hazard.
up to 120,3 K and thermal fuse opened. NB.
No hazard.
63. 2 Ohm load test
(2 channels)
(2 channels)
- 264
V
18 min
0
after 18 min, Q205FR and Q206FR damaged
and protection circuit(RLY301) operated. NB.
No hazard.
and protection circuit(RLY301) operated. NB.
No hazard.
s/c: short circuit, NCD: No component damaged, NB: No Breakdown
Page 29 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
Trademark
Type/model
Value / rating
Standard
Approval/
Reference
Main transformer
Seoul Electronics
& Telecom /
& Telecom /
8200-85863-022-$
(820085863022$)
240 V / 50 Hz
IEC 60065
EN 60065
Tested in
appliance
Alt) Seoul
Electronics
& Telecom /
8200-85863-023-$
(820085863023$)
230 V / 50 Hz
IEC 60065
EN 60065
Tested in
appliance
Stand-by
transformer
transformer
Seoul Electronics
& Telecom /
& Telecom /
8200-28015-053-$
(820028015053$)
240 V / 50 Hz
IEC 60065
EN 60065
Tested in
appliance
Alt) Seoul
Electronics
& Telecom /
8200-28015-054-$
(820028015054$)
230V / 50 Hz
IEC 60065
EN 60065
Tested in
appliance
transformer bobbin LG
LUPOX-GP2306F
V-0 -
UL
PCB (main, power
switch board)
switch board)
Top Faith PCB
TF-03
UL94V-0,
130 °C
UL 796
UL
Mains switch
(SW701)
(SW701)
Postec
SDL1P-B
(Class ll)
250 V / 5 A
IEC 61058-1
EN 61058-
EN 61058-
1
VDE
Relay (RLY301)
Omron
G5PA-1
5 A / 250 V
(Class ll)
IEC 61058-1
EN 61058-1
SEMKO
Alt)
Daiichi
DG1U
8 A / 250 V
(Class ll)
IEC 61058-1
EN 61058-1
SEMKO
Alt)
Handouk
HL3-1A-6SH
5 A / 250 V
(Class ll)
IEC 61058-1
EN 61058-1
SEMKO
Thermal fuse in
mains transformer
mains transformer
NEC SCHOTT
SF152E-1
250 V / 10 A /
157
°C
IEC 60691 E
N 60691
VDE
AC Inlet
Emuden Musen
Kogyo
Kogyo
INL-12 or INL-12-9
15 A / 250 V
EN 60320-1
SEMKO
Alt)
Dong Bo
SA-4P
10 A / 250 V
EN 60320-1
TUV
Alt)
Rong Feng
SS-120
10 A / 250 V
EN 60320-1
VDE
Alt)
Volex
VAC18S
10 A / 250 V
EN 60320-1
SEMKO
X-cap (C304)
Sam Wha
SC
0,0047
μF / 250
V
IEC 384-14
EN 253400
EN 253400
VDE
Alt)
Murata
KC or KH
0.0047
μF / 250
V
IEC 384-14
EN 253400
EN 253400
VDE
Alt)
Pan Overseas
Electronic
Electronic
AC 0.0047
μF / 250
V
V
IEC 60384-
14
EN 253400
VDE
F301 (primary)
Littelfuse Triad
50T or 218
T 4L 250 V
IEC 60127-2
EN 60127-2
EN 60127-2
VDE
Page 30 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Alt) Hollyland 50T
T 4L 250 V
IEC 60127-2
EN 60127-2
EN 60127-2
VDE
Alt) Littelfuse
OVS
618
T 4L 250 V
IEC 60127-2
EN 60127-2
EN 60127-2
VDE
Alt)
Cooper
Bussmann
Bussmann
S506
T 4L 250 V
IEC 60127-2
EN 60127-2
EN 60127-2
SEMKO
Connector (CP306,
CP305, CP304)
CP305, CP304)
Jea Eun
Electronics
Electronics
JE202 series
V-0
-
UL
Alt) Molex
35328
V-0
-
UL
Alt) Yeonho YW396-V
V-0
-
UL
Main plug + Molded
connector +
External flexible
cord, PVC
sheathed
connector +
External flexible
cord, PVC
sheathed
Volex
MP3204
16 A / 250 V
VDE 0620
VDE
Volex
VAC17S
10 A / 250 V
IEC 60320
EN 60320
VDE / ASTA
BaoHing H05VV-F
2
× 1,0 mm
2
VDE
0281 VDE
Alt)
Volex
MP5004
10 A / 250 V
BS 1363
SS145
ASTA /
PSB
Volex
VAC17S
10 A / 250 V
BS 1363
EN60320-1
ASTA
Bao Hing (Shenzh
en)
en)
H05VV-F 2
× 1,0 mm
2
VDE
0281 VDE
Alt)
Volex
AU10S2
7.5 or 10 A /
250 V
AS/NZS
3112
Depertment
of FAIR
TRADING
Volex
PIC17S
10 A / 250 V
AS/NZS
3109.1
Depertment
of FAIR
TRADING
Bao Hing (Shenzh
en)
en)
H05VV-F
2
× 1.0 mm
2
AS/NZS
3191
Depertment
of FAIR
TRADING
Tong Yuan
H05VV-F
2
× 1.0 mm
2
AS/NZS
3191
Depertment
of FAIR
TRADING
1) an asterisk indicates a mark which assures the agreed level of surveillance
2)
$
- May incorporated two suffix number and letter
Page 31 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
N/A
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179
of EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179
of EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet I page 180 of
EN 60 065:2002
comply with Standard Sheet I page 180 of
EN 60 065:2002
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A