Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 20 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
IPX0 N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 21 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
Same as below
—
Position of the functional switch (W) ...................... :
Front
—
Operating conditions
- test signal : pink noise signal wave
- 1/8 of rated output
- connected 6
Ω load to front, center and surround terminals
- supply : 216 V ~ 50 Hz, 264 V
∼ 50 Hz
- wooden test box : not applicable (see Cl. 4.1.4)
Un (V)
Fn (Hz)
In (A)
Pn (W)
Pout (W)
240 50
1.96
406.4
rated
output
216
50
0.89
148.9
1/8 rated output
240
50
0.93
171.1
1/8 rated output *)
264
50
0.98
198.8
1/8 rated output
240 50
0.004
0.8
stand-by
*): 2,47 W x 5
Loudspeaker impedance (
Ω) ............
6
Ω —
Several loudspeaker systems
5 channel stereo
P
Marking of loudspeaker terminals
SPEAKER ; FRONT( 6
Ω ), SURROUND( 6Ω ),
CENTER( 6
Ω )
P
Monitored point:
dT (K)
Limit dT (K)
264 V
∼ 50 Hz
1. Main transformer core
47.7
85
2. Stand-by transformer core
24.0
85
3. RLY301 body
28.3
55
4. Inlet inside
16.2
45
5. AC cord wire terminal(CP306)
20.6
50
6. D111 body
46.5
-
7. D112 body
51.6
-
8. C180 body
22.0
-
9. IC103 heat-sink
49.0
-
10. IC112 heat-sink
35.9
-
11. IC104 body
51.6
-
12. Q206C body
62.5
-
Page 22 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
13. Front panel
5.8
60
14. Main heat-sink left
55.3
-
15. Main heat-sink center
61.0
-
16. Main heat-sink right
56.9
-
17. IC108 body
24.4
-
18. Enclosure above main transformer
20.3
40
19. Enclosure above main heat-sink
29.6
40
Winding temperature rise measurements
P
Ambient temperature t1 (
o
C) .................................. :
Same as below
—
Ambient temperature t2 (
o
C) .................................. :
Same as below
—
Temperature rise dT of winding:
R
1
(
Ω)
R
2
(
Ω)
t1 (°C)
t2 (°C)
dT (K)
Limit dT
(K)
Insulation
class
Mains trans primary (264 V)
7.538
9.442
24.7
26.5
63.7
85
E
Stand-by trans primary (264 V)
4054
4514
24.7
26.5
27.6
85
E
Operating conditions
- test signal : pink noise signal wave
- 1/8 of rated output
- connected 6
Ω load to front, center and surround terminals
- supply : 207 V ~ 50 Hz, 253 V
∼ 50 Hz
- wooden test box : not applicable (see Cl. 4.1.4)
Un (V)
Fn (Hz)
In (A)
Pn (W)
Pout (W)
230 50
1.96
390.7
rated
output
207
50
0.88
140.7
1/8 rated output
230
50
0.90
158.1
1/8 rated output *)
253
50
0.92
176.2
1/8 rated output
230 50
0.004
0.8
stand-by
*): 2,29 W x 5
Loudspeaker impedance (
Ω) ............
6
Ω —
Several loudspeaker systems
5 channel stereo
P
Marking of loudspeaker terminals
SPEAKER ; FRONT( 6
Ω ), SURROUND( 6Ω ),
CENTER( 6
Ω )
P
Monitored point:
dT (K)
Limit dT (K)
253 V
∼ 50 Hz
1. Main transformer core
48.5
85
Page 23 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
2. Stand-by transformer core
25.1
85
3. RLY301 body
29.2
55
4. Inlet inside
17.9
45
5. AC cord wire terminal(CP306)
22.4
50
6. D111 body
44.5
-
7. D112 body
50.3
-
8. C180 body
24.0
-
9. IC103 heat-sink
63.0
-
10. IC112 heat-sink
38.0
-
11. IC104 body
52.9
-
12. Q206C body
61.4
-
13. Front panel
8.0
60
14. Main heat-sink left
52.5
-
15. Main heat-sink center
62.1
-
16. Main heat-sink right
55.3
-
17. IC108 body
23.3
-
18. Enclosure above main transformer
20.3
40
19. Enclosure above main heat-sink
26.9
40
Winding temperature rise measurements
P
Ambient temperature t1 (
o
C) .................................. :
Same as below
—
Ambient temperature t2 (
o
C) .................................. :
Same as below
—
Temperature rise dT of winding:
R
1
(
Ω)
R
2
(
Ω)
t1 (°C)
t2 (°C)
dT (K)
Limit dT
(K)
Insulation
class
Mains trans primary (253 V)
7.259
8.983
25.9
24.3
63.4
85
E
Stand-by trans primary (253 V)
3849
4247
25.9
24.3
28.5
85
E
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T – normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
Connector (CP306)
46.6
-
> 150
- CP306 is the same material as CP305 and CP304
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (M
Ω)
Required R (M
Ω)