Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
Coil formers and partition walls > 0,4 mm 
Between primary and 
secondary windings:                 
main transformer: min. 1,0 
mm, stand-by transformer: min. 
1,7 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II transformers provided 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Isolating transformers provided 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Bobbin provided 
 
Coil formers and partition walls > 0,4 mm 
Between primary winding and 
core:                                        
main transformer: min. 0.9 
mm, stand-by transformer: min. 
1.0 mm 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II transformers provided 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
(see appended table) 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N/A 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
250V 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Between conductors of fuse 
holders: F301: min. 4.4 mm; 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
Certified thermal fuse provided 
in the main transformer 
 
Page 13 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
(see appended table) 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : F301: T4AL / 250 V 
14.5.2.3 
Not possible to connect fuses in parallel  ................ :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... :
 N/A 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC-S 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
Such protective devices are not 
provided 
N/A 
14.6 
Switches 
(see appended table) 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
0.98 A, Cl.7.1 at 264 V
; Mains 
switch and relay were approved 
by VDE or SEMKO. 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 
14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with  14.6.4 and 
V-0 in annex G, G.1.1 
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 N/A 
 
Socket outlet current marking correct 
 
N/A 
 
Page 14 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
14.7 
Safety interlocks 
No safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 Motors 
No 
motors 
N/A 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 N/A 
14.10 Batteries 
No 
batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 Optocouplers 
No 
optocouplers 
N/A 
 
Optocouplers comply with Cl. 8 
 
N/A 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 N/A 
14.12 
Surge suppression varistors 
No varistors 
N/A 
 
Comply with IEC 61051-2 
 
N/A 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
Yes N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 N/A 
 
Page 15 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
 
 
15 TERMINALS 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
(see appended table 14) 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
N/A 
 
No risk of insertion in mains socket-outlets 
 
N/A 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No terminals like 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
No terminals like 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II equipment 
N/A 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to earth
 N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ................... :  
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
No permanently connected 
apparatus 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
N/A 
 
Not soldered to conductors of a printed circuit 
board 
Crimped contacts within plug 
connector 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are crimped two times to 
the contact and provided with a 
two pole-connector 
 
Wire secured by additional means to the conductor Wires insulators are crimped 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
None N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
None N/A 