Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Primary – Enclosure
1 000
4
Primary – Loud speaker terminal
1 000
4
Primary – Other terminals
1 000
4
Parts of different polarity
1 000
2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (Vrms)
Breakdown
Primary – Enclosure
3 000
No
Primary – Loud speaker terminal
3 000
No
Primary – Other terminals
3 000
No
Parts of different polarity
1 500
No
Page 25 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage .............. : 264 V
—
Ambient temperature (
o
C) ...................................... : 23-26
°C
—
fault condition, state
component short- or open
circuited and components
whose temperature rises
are measured
component short- or open
circuited and components
whose temperature rises
are measured
supply
voltage
voltage
result, state effect of fault condition and the duration of the test
duration of t
he test
he test
Input
current(A)
current(A)
result, state effect of fault condition
1. D111 (AC – –)
S/C 264
V
4 s
0
Immediately F301(4A) opened. NCD. No
hazard.
hazard.
2. D112 (AC – +)
S/C 264
V
3 s
0
Immediately F301(4A) opened. NCD. No
hazard.
hazard.
3. C179
S/C 264
V
5 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
4. C180
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
5. Q124 (B – C)
S/C 264
V 46 min
0.19
Normal operation. NCD. No hazard.
6. Q124 (C – E)
S/C 264
V 56 min
0.19
Normal operation. NCD. No hazard.
7. Q126 (C – E)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
8. Q126 (B – E)
S/C 264
V 36 min
0.19
Normal operation. NCD. No hazard.
9. Q125 (B – C)
S/C 264
V 1 h, 22 min
0.17
Immediately ZD103, ZD104, R186 smoked for
2 sec and opened. Front display disappeared.
NB. No hazard.
2 sec and opened. Front display disappeared.
NB. No hazard.
10. Q125 (C – E)
S/C 264
V 28 min
0.17
after 3 s, R186 smoked for 3 sec, and opened.
Q125 damaged. Front display disappeared.
NB. No hazard.
Q125 damaged. Front display disappeared.
NB. No hazard.
11. C189
S/C 264
V 32 min
0.17
Immediately R186 glowed for 1 s and smoked
2 s and opened. Front display disappeared.
NB. No hazard.
2 s and opened. Front display disappeared.
NB. No hazard.
12. D129
S/C 264
V 55 min
0.18
Immediately R205 smoked for 1 s. and
opened. NB. No hazard.
opened. NB. No hazard.
13. C200
S/C 264
V 43 min
0.17
Immediately R205, R206 smoked for 1 sec
and opened. NB. No hazard.
and opened. NB. No hazard.
14. D131
S/C 264
V 46 min
0.17
Immediately R207 smoked for 1 s and
opened. NB. No hazard.
opened. NB. No hazard.
15. D134
S/C 264
V 38 min
0.17
Immediately R208 smoked for 1 s and
opened. NB. No hazard.
opened. NB. No hazard.
16. IC111(In – Out) S/C 264
V 52 min
0.20
REG101 heated up to 57,5 K and stabilized.
NCD. No hazard.
NCD. No hazard.
Page 26 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
17. C222
S/C 264
V 1 h, 08 min
0.22
IC111 heated up to 67.2 K and stabilized.
NCD. No hazard.
NCD. No hazard.
18. IC112(In – Out) S/C 264
V 38 min
0.20
REC100 heated up to 18,1 K and stabilized.
NCD. No hazard.
NCD. No hazard.
19. C219
S/C 264
V 44 min
0.22
IC112 heated up to 69,7 K and stabilized.
NCD. No hazard.
NCD. No hazard.
20. IC108(In – Out) S/C 264
V 45 min
0.19
Normal operation. NCD. No hazard.
21. C223
S/C 264
V 39 min
0.21
IC108 heated up to 51.3 K and stabilized.
NCD. No hazard.
NCD. No hazard.
22. C207
S/C 264
V 29 min
0.16
Immediately R207, R208 smoked for 1 s and
opened. NB. No hazard.
opened. NB. No hazard.
23. IC103 (In – Out)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
24. IC104 (In – Out)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
25. C204
S/C 264
V
5 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
26. C205
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
27. D118
S/C 264
V 32 min
0.19
Normal operation. NCD. No hazard.
28. C176
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
29. C264
S/C 264
V 27 min
0.19
Normal operation. NCD. No hazard.
30. C175
S/C 264
V 34 min
0.19
Normal operation. NCD. No hazard.
31. ZD102
S/C 264
V 39 min
0.19
Normal operation. NCD. No hazard.
32. IC105(4 – 8)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
33. IC105(4 – 5)
S/C 264
V 28 min
0.19
Normal operation. NCD. No hazard.
34. IC105(4 – 6)
S/C 264
V 30 min
0.19
Normal operation. NCD. No hazard.
35. IC105(4 – 7)
S/C 264
V 26 min
0.19
Normal operation. NCD. No hazard.
36. D303
S/C 264
V 2 h, 10 min
0.03
Immediately protection circuit(RLY301)
operated. Priwinding of standby transformer
heated up to 26,9 K and stabilized. NCD. No
hazard.
operated. Priwinding of standby transformer
heated up to 26,9 K and stabilized. NCD. No
hazard.
37. D306
S/C 264 V 1 h, 54 min
0.03
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
38. C302
S/C 264
V 1 h, 55 min
0.04
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,1 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,1 K and
stabilized. NCD. No hazard.
Page 27 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
39. C301
S/C 264
V 2 h, 21 min
0.04
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
40. IC300(In – Out) S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
41. C300
S/C 264
V 49 min
0.03
Immediately protection circuit(RLY301)
operated. IC300 heated up to 17,3 K. NCD.
No hazard.
operated. IC300 heated up to 17,3 K. NCD.
No hazard.
42. C154
S/C 264
V 36 min
0.20
REG101 heated up to 29,1 K and stabilized.
NCD. No hazard.
NCD. No hazard.
43. C151
S/C 264
V 41 min
0.19
REC100 heated up to 24,8 K and stabilized.
NCD. No hazard.
NCD. No hazard.
44. Q205FR (B – C)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
45. Q205FR (C – E)
S/C 264
V
5 s
0
Immediately R220FR, R221FR, R222FR,
R223FR smoked for 1 s and opened. R219FR
smoked for 1 sec and damaged. Q206FR
shorted. Protection circuit(RLY301) operated.
NB. No hazard.
R223FR smoked for 1 s and opened. R219FR
smoked for 1 sec and damaged. Q206FR
shorted. Protection circuit(RLY301) operated.
NB. No hazard.
46. Q205FR (B – E)
S/C 264
V 33 min
0.19
Normal operation. NCD. No hazard.
47. Q206FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
48. Q206FR (C – E)
S/C 264
V
4 s
0
Immediately R220FR, R221FR, R222FR,
R223FR smoked for 1 s and opened.
R218FR damaged. Q205FR shorted.
Protection circuit(RLY301) operated. NB. No
hazard.
R223FR smoked for 1 s and opened.
R218FR damaged. Q205FR shorted.
Protection circuit(RLY301) operated. NB. No
hazard.
49. Q206FR (B – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
50. Q203FR (B – E)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
51. Q203FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
52. Q203FR (C – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
53. Q202FR (B – C)
S/C 264
V
5 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
54. Q202FR (B – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
55. Q202FR (C – E)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
56. Q201FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.