Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 4 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
3 GENERAL
REQUIREMENTS
P
Safety class of the apparatus ................................. : Class II
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
box
For heat dispersal, do not
install this unit in a confined
space such as a bookase or
similar enclosure (written in the
instruction manual)
install this unit in a confined
space such as a bookase or
similar enclosure (written in the
instruction manual)
P
5 MARKING
P
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
Test conducted
P
5.1
Identification, maker, model ................................... : Harman/Kardon, AVR-
133, AVR-134
P
Class II symbol if applicable
Provided double square
marking on the rear panel
marking on the rear panel
P
Rated supply voltage and symbol .......................... : 230 V~; 240 V~
P
Frequency if safety dependant
50 Hz
P
Rated current or power consumption ..................... : 260 W
P
5.2 Earth
terminal
None
N/A
Hazardous live terminals
None
N/A
Supply output terminals (other than mains)
None N/A
5.3
Use of triangle with exclamation mark
In the circuit diagram
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
Described in the instruction ma
nual
nual
P
Hazardous live terminals, instructions for wiring
None
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
N/A
Special stability warning for fixed installation
N/A
Warning: battery exposure to heat
No batteries
N/A
Warning: protective film on CRT face
N/A
Page 5 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
To completely disconnect this p
roduct from the mains, disconn
ect the plug from the wall sock
et outlet (Written in the instructi
on manual)
roduct from the mains, disconn
ect the plug from the wall sock
et outlet (Written in the instructi
on manual)
P
Instructions for permanently connected equipment
No permanently connected equ
ipment
ipment
N/A
6 HAZARDOUS
RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionising radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
N/A
Emission limits under fault conditions .................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
N/A
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table 7.2)
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
By inspection
P
Page 6 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Class II equipment
N/A
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
Class II equipment
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II equipment
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double insulated primary wires
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Main transformer, stand-by
transformer, relay (RLY301)
transformer, relay (RLY301)
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
P
Reinforced insulation > 0,4 mm (mm) .................... : Main transformer, stand-by
transformer, relay (RLY301)
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
None N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulation provided
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P
Page 7 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
PVC wire (UL recognized)
thickness: 0.75 mm + 0.75 mm
thickness: 0.75 mm + 0.75 mm
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All mains wires are provided with a
two pole-connector
two pole-connector
P
Vibration test carried out ......................................... : Yes
P
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
None N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
None N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
All wires are tested with a force
of 2 N
of 2 N
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1 Disconnect
device
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
No switch in the mains cord
N/A
8.21
Bridging components comply with clause 14
C304
P
8.22
Non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No exceeding 1000 V a.c. or
1500 V d.c.
1500 V d.c.
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U2 = Max. 18,2 mVp
P
Discharge not exceeding 45 μC <
45
μC
P
Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
Test conducted
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
N/A