DOWNLOAD Harman Kardon AVR 134 (serv.man2) Service Manual ↓ Size: 1.2 MB | Pages: 62 in PDF or view online for FREE

Model
AVR 134 (serv.man2)
Pages
62
Size
1.2 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-134-sm2.pdf
Date

Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 8 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
Top enclosure: max. 2 
× 18 
mm 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Test conducted 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Test conducted 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set controls 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
0 Vp 
 
If C is not greater than 0,1 μF no test needed 
< 0.1 μF P 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
Test conducted 
 
Test hook of fig. 4 for 10 s (20 N) 
Test conducted 
 
30 mm diameter test tool for 5 s (100 or 250 N)  .... : Applied 100 N 
9.2 
No hazard after removing a cover by hand 
No removing a cover by hand 
N/A 
 
 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. :
100 M
Ω P 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 120 h, 30 °C, 93 %  
10.3 
Insulation resistance and dielectric strength 
between mains teminals 
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I) 
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
 P 
 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
(see appended table 11.2) 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts 
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table 11.2) 
 
Page 9 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 N/A 
11.2.5 
Temperature rise of windings 
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table 11.2) 
 
 
 
12 MECHANICAL 
STRENGTH 
12.1.1 
Bump test where mass >7 kg 
Approx. 8.4 kg (> 7 kg) 
12.1.2 
Vibration test 
Test conducted 
12.1.3 
Impact hammer test 
Test conducted 
 
Steel ball test 
Test conducted (h = 0,4 m) 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
  
N/A 
12.1.5 
Thermoplastic enclosures strain relief test 
Test conducted on front frame 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
N/A 
12.3 
Remote controls with hazardous live parts 
No cable connected remote 
control device 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
Not provided 
N/A 
12.6.1 
Telescoping or rod antennas securement 
Not provided 
N/A 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
Considered 
 
Creepage distances in accordance with 13.4 
Considered 
13.2 
Determination of operating voltage 
Considered 
 
Page 10 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
13.3 
Clearances 
Basic between the mains: min. 
2.0 mm for 346 Vp; Reinforced 
between pri  and sec.: min. 4.0 
mm for 394 Vp 
13.3.2 
Circuits conductively connected to the mains compl
y with table 8 and, where applicable, table 9 
 
Basic: between the mains conduct
ors: min 4,0 mm; between metal b
ottom chassis and  ST-
BY board : min. 9.0 mm; between 
back chassis and CP306 on ST-
BY board: min. 8.4 m; between pri
mary and secondary conductors o
n ST-
BY board: min. 6,4 mm; between s
ide chassis and CP304 on ST-
BY board: min. 8.9 mm; between p
rimary conductor of mains switch b
oard and switch enclosure : 4.2 m
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Non-hazardous secondary 
circuits. 
N/A 
13.4 
Creepage distances 
Basic between the mains: min. 
2.5 mm for 239 Vrms; 
Reinforced between pri  and 
sec.: min. 6.0 mm for 277 Vrms 
 
Creepage distances greater than table 11 minima 
Same as Cl. 13.3.2
 
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N/A 
 
 
 
14 COMPONENTS 
14.1 Resistors 
N/A 
 
Page 11 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
(see appended table) 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved  ........................... : No 
N/A 
14.2 
Capacitors and RC units 
C304 
 
Capacitors separately approved 
Yes (by VDE or SEMKO) 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... : No 
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  ... : X2 (C304: 0.0047 
μF / 250 V) 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ...................... :
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ....................................................................... :
All capacitors do not exceed 
1750 mm³ and except for electrical 
capacitors (C179, C180) 
connected to secondary circuit 
and shielded by metal case
 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ :
All capacitors do not exceed 
1750 mm³ and except for electrical 
capacitors (C179, C180) 
connected to secondary circuit 
and shielded by metal case
 
N/A 
 
Shielded by a barrier to V-0 or metal  ...................... : Yes
 (shielded by metal case : 
C179, C180: max. 43963 mm³ )
 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... :
The transfomers are marked 
with the trademark and type 
designation as appended table. 
 
Transformers and inductors separately approved  . : No (tested in appliance) 
N/A 
14.3.2 General 
 
14.3.3 Constructional 
requirements Bobbin 
provided 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Bobbin provided 
Page of 62
Display