Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 8 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
Top enclosure: max. 2
× 18
mm
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Test conducted
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test conducted
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
0 Vp
P
If C is not greater than 0,1 μF no test needed
< 0.1 μF P
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test conducted
P
Test hook of fig. 4 for 10 s (20 N)
Test conducted
P
30 mm diameter test tool for 5 s (100 or 250 N) .... : Applied 100 N
P
9.2
No hazard after removing a cover by hand
No removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
100 M
Ω P
10.2
Humidity treatment 48 h or 120 h ........................... : 120 h, 30 °C, 93 %
P
10.3
Insulation resistance and dielectric strength
between mains teminals
between mains teminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
(see appended table 11.2)
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Page 9 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N/A
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
12 MECHANICAL
STRENGTH
P
12.1.1
Bump test where mass >7 kg
Approx. 8.4 kg (> 7 kg)
P
12.1.2
Vibration test
Test conducted
P
12.1.3
Impact hammer test
Test conducted
P
Steel ball test
Test conducted (h = 0,4 m)
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
N/A
12.1.5
Thermoplastic enclosures strain relief test
Test conducted on front frame
P
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
No cable connected remote
control device
control device
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
Not provided
N/A
12.6.1
Telescoping or rod antennas securement
Not provided
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
P
13.1
Clearances in accordance with 13.3
Considered
P
Creepage distances in accordance with 13.4
Considered
P
13.2
Determination of operating voltage
Considered
P
Page 10 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
13.3
Clearances
Basic between the mains: min.
2.0 mm for 346 Vp; Reinforced
between pri and sec.: min. 4.0
mm for 394 Vp
2.0 mm for 346 Vp; Reinforced
between pri and sec.: min. 4.0
mm for 394 Vp
P
13.3.2
Circuits conductively connected to the mains compl
y with table 8 and, where applicable, table 9
y with table 8 and, where applicable, table 9
Basic: between the mains conduct
ors: min 4,0 mm; between metal b
ottom chassis and ST-
BY board : min. 9.0 mm; between
back chassis and CP306 on ST-
BY board: min. 8.4 m; between pri
mary and secondary conductors o
n ST-
BY board: min. 6,4 mm; between s
ide chassis and CP304 on ST-
BY board: min. 8.9 mm; between p
rimary conductor of mains switch b
oard and switch enclosure : 4.2 m
m
ors: min 4,0 mm; between metal b
ottom chassis and ST-
BY board : min. 9.0 mm; between
back chassis and CP306 on ST-
BY board: min. 8.4 m; between pri
mary and secondary conductors o
n ST-
BY board: min. 6,4 mm; between s
ide chassis and CP304 on ST-
BY board: min. 8.9 mm; between p
rimary conductor of mains switch b
oard and switch enclosure : 4.2 m
m
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Non-hazardous secondary
circuits.
circuits.
N/A
13.4
Creepage distances
Basic between the mains: min.
2.5 mm for 239 Vrms;
Reinforced between pri and
sec.: min. 6.0 mm for 277 Vrms
2.5 mm for 239 Vrms;
Reinforced between pri and
sec.: min. 6.0 mm for 277 Vrms
P
Creepage distances greater than table 11 minima
Same as Cl. 13.3.2
P
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 COMPONENTS
P
14.1 Resistors
N/A
Page 11 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
(see appended table)
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved ........................... : No
N/A
14.2
Capacitors and RC units
C304
P
Capacitors separately approved
Yes (by VDE or SEMKO)
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : No
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... : X2 (C304: 0.0047
μF / 250 V)
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
All capacitors do not exceed
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
All capacitors do not exceed
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
N/A
Shielded by a barrier to V-0 or metal ...................... : Yes
(shielded by metal case :
C179, C180: max. 43963 mm³ )
P
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
The transfomers are marked
with the trademark and type
designation as appended table.
with the trademark and type
designation as appended table.
P
Transformers and inductors separately approved . : No (tested in appliance)
N/A
14.3.2 General
P
14.3.3 Constructional
requirements Bobbin
provided
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Bobbin provided
P