Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 16 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Crimped the insulators and
conductors
conductors
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16 No terminals like
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
No terminals like
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
No terminals like
N/A
Terminals located and shielded: test with 8 mm
strand
strand
Crimped contacts within plug
connector
connector
P
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
No devices like
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
PVC sheathed (refer to
appended table 14)
appended table 14)
P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Class II
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
0.98 A, Cl.7.1 at 264 V
∼
: 2
×
0.75 mm
2
:
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnection cord
N/A
Page 17 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of
IEC 60227-2)
bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
No flexible cords like
N/A
16.5
Adequate strain relief on external flexible cords
Inlet provided
N/A
Not possible to push cord back into equipment
Inlet provided
N/A
Strain relief device unlikely to damage flexible cord Inlet provided
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II equipment
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Inlet provided
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
No transportable musical
instruments
instruments
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
P
17.1
Torque test to table 20:
P
- screws into metal: 5 times
Cover fixing screws: sides: 4.0
mm diameter, 1.2 Nm; rear: 3.0
mm diameter, 0.5 Nm
mm diameter, 1.2 Nm; rear: 3.0
mm diameter, 0.5 Nm
P
- screws into non-metallic material: 10 times
Metal enclosure
N/A
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N/A
17.3
Cover fixing screws: captive
No captive screws
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
No danger by using of longer
screws
screws
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
N/A
Page 18 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminals
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover-fixing devices
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Test conducted by a pull of 2 N
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube
N/A
Picture tube separately approved to 18.1 ...............
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ................. : Approximately 8.4 kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested
P
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No the glass breaks or cracks
N/A
Page 19 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
19.6
Wall or ceiling mountings adequate
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
Diodes, TRs
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
Mains switch(SW701),
Relay(RLY301)
Relay(RLY301)
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Standby, power switch board
flammability category FV 0 and
metal enclosure was provided
flammability category FV 0 and
metal enclosure was provided
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
< 400 V
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
(see appended table)
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
< 4 Kv
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.