Page 16 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Crimped the insulators and 
conductors 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 No terminals like 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
No terminals like 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
No terminals like 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
Crimped contacts within plug 
connector 
15.4 
Devices forming a part of the mains plug 
 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
No devices like 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 N/A 
 
16 
EXTERNAL FLEXIBLE CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ :
PVC sheathed (refer to 
appended table 14) 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
0.98 A, Cl.7.1 at 264 V 
: 2 
× 
0.75 mm
2
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
No interconnection cord 
N/A 
 
Page 17 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of 
IEC 60227-2) 
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
No flexible cords like 
N/A 
16.5 
Adequate strain relief on external flexible cords 
Inlet provided 
N/A 
 
Not possible to push cord back into equipment 
Inlet provided 
N/A 
 
Strain relief device unlikely to damage flexible cord Inlet provided 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
Class II equipment 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
Inlet provided 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
No transportable musical 
instruments 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N/A 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
17.1 
Torque test to table 20: 
 
 
- screws into metal: 5 times 
Cover fixing screws: sides: 4.0 
mm diameter, 1.2 Nm; rear: 3.0 
mm diameter, 0.5 Nm 
 
- screws into non-metallic material: 10 times 
Metal enclosure 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material 
 N/A 
17.3 
Cover fixing screws: captive 
No captive screws 
N/A 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
No danger by using of longer 
screws  
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
 P 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 N/A 
 
Page 18 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No cover-fixing devices 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Test conducted by a pull of 2 N 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965: 
No picture tube 
N/A 
 
Picture tube separately approved to 18.1  ...............   
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 N/A 
 
Protective film as part of implosion protection: 
edges covered by enclosure 
 N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
N/A 
18.2.1 
Samples subject to ageing: 6 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
N/A 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg  ................. : Approximately 8.4 kg 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
Tested 
19.2 
100 N force applied vertically downwards 
 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 
19.4 
Edges or corners not hazardous 
 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1 
No the glass breaks or cracks 
N/A 
 
Page 19 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
19.6 
Wall or ceiling mountings adequate 
 
N/A 
 
 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1 
Diodes, TRs  
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
Mains switch(SW701), 
Relay(RLY301) 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
Standby, power switch board 
flammability category FV 0 and 
metal enclosure was provided 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
< 400 V 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
(see appended table) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 N/A 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
< 4 Kv 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 