Report Ref. No. 077-204389-000 
 
Clause Requirement 
− Test 
Result 
− Remark 
Verdict 
 
 
 
TRF No. IECEN60065G 
 
15.1.1 
Apparatus which is fitted with a flexible cable or 
cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets 
etc. (Safety) Regulations 1994, unless exempted 
by those Regulations.  
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved 
conversion plug.  
Justification:  
SI 1768: 1994 
 P 
NO
 
13.3.1 
To the second paragraph the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. Justification: Based on a use in Norway of 
an IT power distribution system where the neutral 
is not provided. 
 N/A 
 
Page 11 of 22 
Report Ref. No. 077-204389-000 
 
Clause Requirement 
− Test 
Result 
− Remark 
Verdict 
 
 
 
TRF No. IECEN60065G 
 
15.1.1 
Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as fas as a Applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2,5 A 250 V two-pole socket-outlets for 
electronic apparatus shall comply with the 
enclosed Standard Sheet I. 
§ 24 Mechanical strength 
a 2,5 A, 250 V socket-outlets for CLASS II 
electronic apparatus are tested as specified in 
12.1.3 of EN 60065. 
Also the protecting rim shall be tested. 
Justification:  
Act of 24 May 1929 relating to supervision of 
electrical installation (TEA 1929/FEL 1998). 
 N/A 
J.2 
After Table J.1 the following is added: In Norway, 
due to the IT power distribution system used, the 
a.c. MAINS supply voltage is considered to be 
equal to the line-to-line voltage, and will remain 
230 V in case of a single earth fault. Justification
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 N/A 
Annex B 
Replace NOTE 1 by  
In the CENELEC countries listed in IEC 62151, 
special national conditions apply.  
Add the following:  
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151).  
 N/A 
 
Page 12 of 22 
Report Ref. No. 077-204389-000 
 
Clause Requirement 
− Test 
Result 
− Remark 
Verdict 
 
 
 
TRF No. IECEN60065G 
 
 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph:  
NOTE – In Norway, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket –outlet.  
The marking text shall be as follows:  
“Apparatet skal tilkoples jordet stikkontakt”  
Subclause 5.3.1 (Corrigendum 1):  
Add after the first test specifications paragraph:   
 N/A 
 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2.  
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001):  
 N/A 
 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either  
two layers of thin sheet material, 
each of which shall pass the electric 
strength test below, or – one layer 
having a distance through insulation 
of at least 0,4 mm, which shall pass 
the electric strength test below.  
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
 N/A 
 
Page 13 of 22 
Report Ref. No. 077-204389-000 
 
Clause Requirement 
− Test 
Result 
− Remark 
Verdict 
 
 
 
TRF No. IECEN60065G 
 
 
passes the test and inspection 
criteria of 13.6 with an electric 
strength test of 10.3 using the test 
voltage of 1,5 kV multiplied by 1,6, 
and  
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1).  
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2.  
 N/A 
 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the 
following conditions:  
the insulation requirements are 
satisfied by having a capacitor 
classified Y3 as defined by IEC 
60384-14, which in addition 
to the Y3 testing, is tested with an 
Impulse test of 2.5kV defined in IEC 
62151, subclause 6.2.1;  
the additional testing shall be 
performed on all the test specimens 
as described in IEC 60384-14;  
- the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in the 
sequence of tests as 
described in IEC 60384-14.  
 N/A 
 
Subclause 5.3.2 (Corrigendum 1):  
Add after the fourth dash: 
NOTE –In Norway, exclusions are applicable for 
equipment which is intended for connection to the 
building installation 
wiring using screw terminals or other reliable 
means, and for equipment which is intended for 
connection to the building installation wiring via an 
industrial plug and socket –outlet or an appliance 
coupler, or both, complying with IEC 60309 or 
with a comparable national standard. 
 N/A 
SE
 
Page of 62
Display

Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.