Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate ▷ View online
Page 18 of 22
Report Ref. No. 077-204389-000
Clause Requirement
− Test
Result
− Remark
Verdict
TRF No. IECEN60065G
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
N/A
Annex G
Delete the note.
N/A
Annex J.2 Delete the notes of Table J.1.
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
For ROUTINE TEST reference is made to EN
50333.
N/A
Bibliograp
hy
hy
Add the following standards:
EN 60332-1: 2000, Sound system equipement: Headphones and earphones
associated with portable audio equipment –Maximum sound pressure level
measurement methodology and limit considerations – Part 1: General method
for ”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and
earphones associated with portable audio equipment – Maximum sound pressure
level measurement methodology and limit considerations – Part 2:Guidelines to
associate sets with headphones coming from different manufacturers.
Add the following notes for the standards indicated:
EN 60332-1: 2000, Sound system equipement: Headphones and earphones
associated with portable audio equipment –Maximum sound pressure level
measurement methodology and limit considerations – Part 1: General method
for ”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and
earphones associated with portable audio equipment – Maximum sound pressure
level measurement methodology and limit considerations – Part 2:Guidelines to
associate sets with headphones coming from different manufacturers.
Add the following notes for the standards indicated:
P
IEC 60130
NOTE
Parts 9 and 17: 1998 are harmonized as Ens (not
modified).
modified).
IEC 60169
NOTE
Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE
Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56
NOTE
Harmonized as EN 60335-2-56: 1997 (not modified).
IEC 60335-2-82
NOTE
Harmonized as EN 60335-2-82: 2000 (not modified).
IEC 60695
NOTE
Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE
Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1
NOTE
Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4
NOTE
Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6
NOTE
Harmonized as EN 61558-2-6: 1997 (not modified).
Annex ZA
(normative)
Other international publications quoted in this standard with the references
of the relevant European publications
⎯
This European Standard incorporates by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies
(including amendments).
NOTE When an international standard has been modified by common
modification, indicated by (mod), the relevant EN/HD applies.
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies
(including amendments).
NOTE When an international standard has been modified by common
modification, indicated by (mod), the relevant EN/HD applies.
P
Page 19 of 22
Report Ref. No. 077-204389-000
Clause Requirement
− Test
Result
− Remark
Verdict
TRF No. IECEN60065G
P
P
Page 20 of 22
Report Ref. No. 077-204389-000
Clause Requirement
− Test
Result
− Remark
Verdict
TRF No. IECEN60065G
P
Page 21 of 22
Report Ref. No. 077-204389-000
Clause Requirement
− Test
Result
− Remark
Verdict
TRF No. IECEN60065G
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
5.1 i)
in EN 60065:2002
Replace
the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
made to EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1 Add
the following indent:
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
can cause hearing loss.
P
6.1
in EN 60065:2002
Replace
the subclause by:
N/A
6.1 Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the
amount of radiation. The amount of radiation is determined by means of a
radiation monitor of the ionizing chamber type with an effective area of 1 000 mm2
or by measuring equipment of other types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service
controls adjusted so as to give maximum radiation whilst maintaining the
equipment operative for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the
equipment are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate
shall not exceed 1 μSv/h (0,1 mR/h) (see Note). Account shall be taken of the
background level.
NOTE These values appear in Directive 96/29/Euratom.
amount of radiation. The amount of radiation is determined by means of a
radiation monitor of the ionizing chamber type with an effective area of 1 000 mm2
or by measuring equipment of other types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service
controls adjusted so as to give maximum radiation whilst maintaining the
equipment operative for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the
equipment are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate
shall not exceed 1 μSv/h (0,1 mR/h) (see Note). Account shall be taken of the
background level.
NOTE These values appear in Directive 96/29/Euratom.
N/A
Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.