5-39
3-1-6. Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Fig. 5-3-3 shows the 75% color bar signals recorded on the alignment
tape for Audio Operation Check.
Note:
Measure with video terminal (Terminated at 75 
)
Use
Tape path adjustment
Switching position adjustment
Audio system adjustment
Operation check
BIST check
Name
Tracking standard (XH2-1)
SW/OL standard (XH2-3)
Audio operation check
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
(XH5-5 (NTSC), XH5-5P (PAL))
BIST check
(XH5-6 (NTSC), XH5-6P (PAL))
For NTSC model
For PAL model
Color bar signal waveform
Color bar pattern
Color bar signal waveform
Color bar pattern
Fig. 5-3-3. Color bar signal of alignment tapes
3-1-7. Input/Output Level and Impedance
Video input/output
Special stereo mini jack
Video signal:
1 Vp-p, 75 
 unbalanced,
sync negative
S video input/output
4-pin mini DIN
Luminance signal:
1 Vp-p, 75 
 unbalanced,
sync negative
Chrominance signal: 0.286 Vp-p, 75 
 unbalanced (NTSC)
: 0.300 Vp-p, 75 
 unbalanced (PAL)
Audio input/output
Special stereo mini jack
Input level: 327mV
Input impedance: More than 47k
Output level: 327 mV (at load impedance 47 k
)
Output impedance: Below 2.2 k
1V
0.714V
0.286V
White (75%)
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
0.286V
Q
I
Horizontal sync signal
(75%)
White
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
1V
0.7V
0.3V
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3V
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
5-40
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of B, C, D, E, F Page Data
If the B, C, D, E, F page data is erased due to some reason, perform
“1-2. INITIALIZATION OF B, C, D, E, F PAGE DATA”, of “5-1.
CAMERA SECTION ADJUSTMENT”
2. Battery End Check (VC-217 board)
Check the battery end voltage.
Mode
Camera recording
Subject
Arbitrary
Switch setting
1)
AUTO FOCUS ................................................................. OFF
2)
LCD screen .................................................................. Closed
3)
REC LAMP (Menu display) ............................................. ON
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
6)
Check that the REC LAMP is lit continuously.
7)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.50 ± 0.01Vdc.
8)
Check that the REC LAMP blinks at 0.8 Hz.
Regulated power supply
Digital volt meter
5.5 
}
 0.01 Vdc
Fig. 5-3-4.
5-41
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
Adjusting Procedure:
1.
Cap FG duty adjustment
2.
T-reel FG duty adjustment
3.
PLL f
0
 & LPF f
0
 adjustment
4.
Switching position adjustment
5.
AGC center level and APC & AEQ adjustment
6.
PLL f
0
 & LPF f
0
 final adjustment
1. Cap FG Duty Adjustment (VC-217 board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
00
Adjusting method:
1)
Close the cassette compartment without inserting a cassette.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 01, set data: 1B, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 02, and check that the data changes
starting from “1B” to “2B” to “00” in this order.
5)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If the data of page: 3, address: 03 is “01”, adjustment has errors
or the mechanism deck is defective.
6)
Select page: 0, address: 01, and set data: 00.
2. T reel FG Duty Adjustment (VC-217 board)
Adjust the take-up reel FG signal duty cycle to an appropriate value
so that the correct T-reel FG signal is obtained.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
17
Specified Value
00
Adjusting method:
1)
Close the cassette compartment without inserting a cassette.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 01, set data: 1C, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 02, and check that the data changes
starting from “1C” to “2C” to “00” in this order.
5)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If the data of page: 3, address: 03 is “02”, adjustment has errors
or the mechanism deck is defective.
6)
Select page: 0, address: 01, and set data: 00.
3. PLL f
0
 & LPF f
0
 Adjustment (VC-217 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 47
Specified Value
Bit2, bit3 and bit6 are “0”
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data changes to
“00”.
4)
Select page: 3, address: 03, and check that bit2, bit3 and bit 6
of the data are “0”.
Note:
If bit2, bit3 or bit 6 of the data is “1”, there are errors. (For the
error contents, see the following table. For the bit values, refer
to “5-4. SERVICE MODE”, “4-3. 3. Bit value discrimination”.)
5)
Select page: 0, address: 01, and set data: 00.
Bit value of page: 3,
address: 03 data
bit 4 = 1
bit 5 = 1
bit 6 = 1
bit 3 = 1
bit 2 = 1
Error contents
PLL f
0
, even channel is defective
PLL f
0
, odd channel is defective
LPF f
0
 is defective
PLL f
0
, final adjustment is defective
PLL f
0
, final adjustment time-out
5-42
4. Switching Position Adjustment (VC-217 board)
Mode
VTR playback
Signal
SW/OL reference tape (XH2-3)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
00
Adjusting method:
1)
Insert the SW/OL reference tape and enter the VTR STOP
mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 21, and check that the data is “02”.
Note:
If the data of page: 3, address: 21 is “72”, the tape top being
played. After playing the tape for 1 to 2 seconds, perform step 4
and higher.
4)
Select page: 3, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 3, address: 02, and check that the data changes to
“00”.
6)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If bit 0 of page: 3, address: 03 data is “1”, the even channel is
defective. If bit 1 is “1”, the odd channel is defective. Contents
of the defect is written into page: C, addresses: 10 and 12. See
the following table. (For the bit values, refer to “5-4. SERVICE
MODE”, “4-3. 3. Bit value discrimination”. )
7)
Select page: 0, address: 01, and set data: 00.
When the even channel is defective
When the odd channel is defective
Data of page: C,
address: 10
EE
E8
E7
Contents of defect
Writing into EEPROM (IC2404) is defective
Adjustment data is out of range
No data is returned from IC1900 (TRX)
Data of page: C,
address: 12
EE
E8
E7
Contents of defect
Writing into EEPROM (IC2404) is defective
Adjustment data is out of range
No data is returned from IC1900 (TRX)
5. AGC Center Level and APC & AEQ Adjustment
5-1. Preparations before adjustments
Mode
Camera recording
Subject
Arbitrary
Adjusting method:
1)
Select page: 2, address: 30, and set data: 40.
2)
Record the camera signal for three minutes.
5-2. AGC Center Level Adjustment (VC-217 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin @º of CN2904 (RF MON) (Note 1)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The display data of page: 3, address:
03 is “00”
Note 1:
Connect a 75
 resistor between Pin @º and Pin !ª (GND) of
CN2904.
75
 resistor (Parts code: 1-247-804-11)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Playback the recorded signal at “Preparations before
adjustments”
3)
Select page: 3, address: 33, and set data: 08.
4)
Confirm that the playback RF signal is stable.
5)
Select page: 3, address: 01, set data: 23, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 3, address: 02, and check that the data is “00”.
7)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors. (Take an appropriate remedial measures according
to the errors referring to the following table. )
8)
Perform “APC & AEQ Adjustment”.
Note 2:
If this data is displayed twice successively, the machine is defective.
Data of page: 3,
address: 03
20
30
40
50
Contents of defect
Perform re-adjustment. (Note 2)
The machine is defective
Perform re-adjustment (Note 2)
The machine is defective
CN2904
VC-217 board