DOWNLOAD Sony DCR-TRV10 / DCR-TRV10E / DCR-TRV8 / DCR-TRV8E (serv.man2) Service Manual ↓ Size: 35.38 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV10 DCR-TRV10E DCR-TRV8 DCR-TRV8E (serv.man2)
Pages
127
Size
35.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
dcr-trv10-dcr-trv10e-dcr-trv8-dcr-trv8e-sm2.pdf
Date

Sony DCR-TRV10 / DCR-TRV10E / DCR-TRV8 / DCR-TRV8E (serv.man2) Service Manual ▷ View online

5-7
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
e
llow
Cyan
Green
White
Magenta
Red
Blue
Y
ellow
Cyan
Green
White
Magenta
Red
Blue
Color bar chart standard picture frame
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments without loading cassette.
1.
POWER switch (PS4550 block) ............................ CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
DEMO MODE (Menu display) ....................................... OFF
4.
DIGITAL ZOOM (Menu display) ................................... OFF
5.
STEADY SHOT (Menu display) ..................................... OFF
6.
16 : 9 WIDE (Menu display) ............................................ OFF
7.
PICTURE EFFECT (Menu display) ................................ OFF
8.
WHITE BALANCE (Menu display) ........................... AUTO
9.
DISPLAY (Menu display) ................................. V-OUT/LCD
10. DISPLAY (CK-84 board) ................................................. ON
11. FOCUS switch (CK-84 board) .............................. MANUAL
12. PROGRAM AE (CF block) ......................................... AUTO
13. DIGITAL EFFECT (CF block) ........................................ OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.5-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5. using A0 size (1189mm 
×
841mm) black and white vellum paper.
Fig. 5-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
5-8
1-2.
INITIALIZATION OF B, C, D, E, F PAGE DATA
1-2-1.
INITIALIZATION OF C PAGE DATA
1. Initializing the C Page Data
Note:
If the C page data has been initialized, the following adjustments
need to be performed again.
1) Modification of C page data
2) Servo and RF system adjustments
3) Video system adjustments
4) IR transmitter adjustments
Adjusting page
C
Adjusting Address
10 to DF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 80, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 80, and check that the data changes to
“1C”.
4)
Perform “Modification of C Page Data”.
2. Modification of C Page Data
If the C page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
  If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. C  Page Table
Note:
Fixed data-1 : Initialized data. (Refer to “1. Initializing the C Page
Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of C Page
Data”.)
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
EE
00
EE
00
E0
E0
2A
2A
33
33
25
3E
3E
CA
99
88
E3
A1
8A
2D
52
04
00
00
00
00
00
00
00
00
00
Switching position adj.
Fixed data-1
(Initialized data)
Cap FG duty adj.
T reel FG duty adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL f
0
 adj.
APC adj.
LPF f
0
 adj.
Fixed data-1
(Initialized data)
S VIDEO OUT Y level adj.
S VIDEO OUT chroma level adj.
S VIDEO OUT chroma level adj.
IR video carrier freq. adj.
IR video deviation adj.
IR audio deviation adj.
Chroma BPF f
0
 adj.
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Emergency memory address
EE
00
EE
00
E0
E0
2A
2A
33
33
25
3E
3E
CA
99
88
E3
A1
8A
2D
52
04
00
00
00
00
00
00
00
00
00
Address
Remark
Initial value
NTSC PAL
5-9
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
00
00
00
20
03
80
00
00
00
20
03
80
Emergency memory address
Fixed data-1
(Initialized data)
PLL f
0
 fine adj.
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
APC adj.
Fixed data-1
(Initialized data)
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
PLL adj.
Fixed data-1
(Initialized data)
Address
Remark
Initial value
NTSC PAL
Address
Remark
Initial value
NTSC PAL
5-10
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Table. 5-1-2.
1-2-2.
INITIALIZATION OF D PAGE DATA
1. Initializing the D Page Data
Note:
If the D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of D page data
2) Color viewfinder system adjustments
3) LCD system Adjustments
Adjusting page
D
Adjusting Address
10 to 9F
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 80, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 80, and check that the data changes to
“1D”.
4)
Perform “Modification of D Page Data”.
2. Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
Note:
If the following symptoms occur after completing of the
“Modification of D page data”, check that the data of the “Fixed
data-2” addresses are same as those of the same model of the same
destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
Address
Remark
Initial value
NTSC PAL
Page of 127
Display

Click on the first or last page to see other DCR-TRV10 / DCR-TRV10E / DCR-TRV8 / DCR-TRV8E (serv.man2) service manuals if exist.