5-31
1-5.
LCD SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3:
Set the LCD BRIGHT to the center.
Set the LCD COLOR (Menu display) to the center.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN2904 of the VC-217 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
A).
The following table shows the Pin No. and signal name of CN2904.
Pin No.
1
3
5
7
9
11
13
15
17
19
Signal Name
LANC SIG
EVF BL –
EVF VCO
PD VG
H START
PANEL COM
TCK
TDO
SWP
GND
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
EVF BL +
EVF VG
GND
PD VCO
XHD/PSIG
TMS
TDI
GND
RF IN/LANC JACK IN
RF MON
Table 5-1-8.
1. VCO Adjustment (PD-110 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
arbitrary
Measurement Point
Pin 9 of CN2904 (H START) on
VC-217 board
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
84
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 03, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 84, change the data and set the
frequency (f) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-17.
CN2904
1
2
19
20
Remove the CPC cover
5-32
2. D range Adjustment (PD-110 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 7 of CN2904 (PD VG) on
VC-217 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
82
Specified Value
A = 3.45 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 82, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
3. Bright Adjustment (PD-110 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 7 of CN2904 (PD VG) on
VC-217 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
8A
Specified Value
A = 1.70 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 2, address: 0E, and set data: 40.
5)
Select page: D, address: 8A, change the data and set the voltage
(A) between the pedestal and GAMMA1 limiter level to the
specified value. (The data of address: 8A should be “1E” to
“A0”.)
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 2, address: 0E, and set data: 00.
8)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-18.
Fig. 5-1-19.
Pedestal
A
2H
Pedestal 
Pedestal
A
2H
GAMMA 1 limiter lavel
5-33
4. Contrast Adjustment (PD-110 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 7 of CN2904 (PD VG) on
VC-217 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
8C
Specified Value
A = 2.95 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 8C, change the data and set the voltage
(A) between the 0 IRE (pedestal) and 100 IRE to the specified
value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
5. V-COM Level Adjustment (PD-110 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin !¡ of CN2904 (PANEL COM) on
VC-217 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
83
Specified Value
A = 6.50 ± 0.05V
Note :
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 83, change the data and set the PANEL
COM signal level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-20.
Fig. 5-1-21.
0 IRE
100 IRE
A
2H
A
2H
5-34
6. V-COM Adjustment (PD-110 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
85
Specified Value
The brightness difference between the
section A and section B is minimum.
Note1 :
Perform “Bright Adjustment” and “Contrast Adjustment” before
this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 2, address: 0E, and set data: 20.
5)
Select page: D, address: 85, change the data so that the
brightness of the section A and that of the section B is equal.
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 2, address: 0E, and set data: 00.
8)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
7. White Balance Adjustment (PD-110 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
80, 81
Specified Value
The LCD screen should not be
colored.
Note 1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5502
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 0B, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 80 and 81, set the data to the initial
value.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
5)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: 80 and 81 so that the LCD screen
is not colored.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-22.
A
A
A
A
B
B
B
B
Address
DCR-TRV10
Data
DCR-TRV8
DCR-TRV10E
DCR-TRV8E
80
97
91
A6
C1
81
70
88
73
8E