DOWNLOAD Sharp MX-M950 / MX-MM1100 (serv.man40) Service Manual ↓ Size: 27.14 MB | Pages: 86 in PDF or view online for FREE

Model
MX-M950 MX-MM1100 (serv.man40)
Pages
86
Size
27.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Section 9 Maintenance
File
mx-m950-mx-mm1100-sm40.pdf
Date

Sharp MX-M950 / MX-MM1100 (serv.man40) Service Manual ▷ View online

MX-M1100  MAINTENANCE  9 – 25
7)
Disconnect the connector (a), and remove the screw (b). 
Remove the DV duct cover (c).
* Use extra care not to foul the connecter terminal section.
8)
Remove the screw (a), and remove the guide (b).
9)
Remove the cover (a).
10) While rotating the coupling (a), discharge old developer (b).
* Rotate the MG roller clockwise and counterclockwise to
remove developer from the MG roller. 
11) Remove the DV side seal F (a) and the DV side seal R (b).
12) Remove the screw (a), and remove the doctor cover unit (b).
Clean the doctor section with dry cloth. Do not use alcohol.
* Rotate the MG roller and check to confirm that there is no
foreign material in the doctor gap section. 
13) Clean the DV side seal attaching section of the DV side plate F
(a) and the DV side plate R (b) with dry cloth. Do not use alco-
hol.
14) Replace the doctor cover unit (a) with new one, and install and
fix with the screw (b). 
* When installing, check to confirm that the positioning boss
(c) is securely engaged. 
* After installing, check to confirm that the cover is not
deformed. 
a
b
c
a
a
b
a
a
b
a
b
b
a
a
a
b
a
b
b
c
c
MX-M1100  MAINTENANCE  9 – 26
15) Replace the DV side seal F (a) and the DV side seal R (b) with
new ones and attach them according to the reference.
* When attaching, be careful not to deform the seals. 
16) Replace the DV filter unit (a).
17) Replace the DV BOX filter (a).
18) While rotating the coupling (a), supply new developer (b).
* Use two bags. (Supply amount 930g = 465g 
✕ 2 bag)
a
b
a
a
a
b
MX-M1100  MAINTENANCE  9 – 27
9. Toner supply section
A. Maintenance table
✕: Check (Clean, replace, or adjust as necessary.)   {: Clean   ▲: Replace    U: Adjust   ✩: Lubricate    †: Shift the position
B. Details
1)
Pull out the toner tray (a), and remove the toner bottle (b).
* Replacement of the toner bottle is performed by the user
when toner is exhausted.
2)
Put your hand into the toner tray and clean the shutter section
(a) of the toner hopper unit at every 500K.
No.
Part name
When 
calling
500
K
1000
K
1500
K
2000
K
2500
K
3000
K
Remark
[Refer to the Parts Guide. Block/Item No.]
(Only the replacement  parts are described.)
1
Toner bottle
Attach when installing. When it is emptied, replacement 
is made by the user. 
2
Toner hopper
{
{
{
{
{
{
{
Clean the shutter area.
2
1
a
b
a
MX-M1100  MAINTENANCE  9 – 28
10. Fusing section
A. Maintenance table
✕: Check (Clean, replace, or adjust as necessary.)   {: Clean   ▲: Replace    U: Adjust   ✩: Lubricate    †: Shift the position
No.
Part name
When 
calling
500
K
1000
K
1500
K
2000
K
2500
K
3000
K
Remark
[Refer to the Parts Guide. Block/Item No.]
(Only the replacement  parts are described.)
1
Upper heat roller
* Differs depending on the model.
Apply grease to the bearing section when replacing. 
(UKOG-0235FCZZ)
[PG No.: [47] - 57]
2
Upper heat roller ball bearing
Must be free from abnormal noises when rotating.
Apply grease when replacing. (UKOG-0235FCZZ)
[PG No.: [47] - 56]
3
Upper heat roller insulation bush
Apply grease when replacing. (UKOG-0235FCZZ)
[PG No.: [47] - 55]
4
Upper heat roller gear
Check/Apply grease when replacing. (UKOG-0235FCZZ)
[PG No.: [47] - 54]
5
Upper heat roller separation pawl
Clean and remove foreign material.
[PG No.: [49] - 7]
6
Non-contact thermistor
7
Sub thermistor
Clean and remove foreign material.
[PG No.: [47] - 38]
8
Upper heater lamp
[PG No.: [47] - 58]
9
Lower heat roller
Apply grease to the bearing section when replacing.
(UKOG-0235FCZZ)
[PG No.: [48] - 30]
10
Lower heat roller ball bearing
Must be free from abnormal noises when rotating.
Apply grease when replacing. (UKOG-0235FCZZ)
[PG No.: [48] - 29]
11
Lower heat roller separation pawl
Clean and remove foreign material.
[PG No.: [48] - 21]
12
Paper guides
{
{
{
{
{
{
{
13
Upper heat roller drive gear
Check/Apply grease when replacing. (UKOG-0235FCZZ)
[PG No.: [48] - 15]
14
Web roller
[PG No.: [46] - 15]
15
Web backup roller
[PG No.: [46] - 14]
16
Web backup roller bearing
[PG No.: [46] - 13]
17
Web motor
[PG No.: [47] - 49]
18
Other ball bearing
Must be free from abnormal noises when rotating.
19
Front upper paper guide
{
[PG No.: [48] - 70]
20
Web guide shaft
[PG No.: [46] - 30]
21
Web guide bearing
[PG No.: [46] - 31]
16
21
18
12
12
8
13
15
10
10
17
20
16
21
3 2
1
6
7
3
2
18
12
9
11
11
14
4
5
5
19
Page of 86