DOWNLOAD Sharp MX-M950 / MX-MM1100 (serv.man40) Service Manual ↓ Size: 27.14 MB | Pages: 86 in PDF or view online for FREE

Model
MX-M950 MX-MM1100 (serv.man40)
Pages
86
Size
27.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Section 9 Maintenance
File
mx-m950-mx-mm1100-sm40.pdf
Date

Sharp MX-M950 / MX-MM1100 (serv.man40) Service Manual ▷ View online

MX-M1100  MAINTENANCE  9 – 21
15) Check the transfer cleaning brush (a) at every 500K, and
cleaning them at every 300K. 
16) Check the transfer sub blade (a) at every 500K.
17) Disconnect the connector (a), and remove the screw (b).
Remove the transfer frame (c).
18) Check each gear (a) at every 3000K.
19) Check the bearing (a) at every 3000K.
20) Clean the discharge plate (a), and the discharge plate holder
(b) at every 500K.
21) Remove the screw (a) and remove the holder unit (b).
22) Slide remove the transfer sub blade (a), and replace it.
a
a
a
b
b
c
a
a
a
b
a
a
a
b
a
MX-M1100  MAINTENANCE  9 – 22
23) Remove the screw (a), and remove the mounting plate (b).
Remove the stopper (c), the gear (d), the E-ring (e), and the
bearing (f).
24) Remove the screw (a), and remove the mounting plate (b).
Remove the E-ring (c), the bearing (d), and the bearing (e).
25) Replace the transfer cleaning brush (a).
a
b
c
d
e
f
a
b
c
d
e
a
MX-M1100  MAINTENANCE  9 – 23
8. Developing section
A. Maintenance table
✕: Check (Clean, replace, or adjust as necessary.)   {: Clean   ▲: Replace    U: Adjust   ✩: Lubricate    †: Shift the position
No.
Part name
When 
calling
500
K
1000
K
1500
K
2000
K
2500
K
3000
K
Remark
[Refer to the Parts Guide. Block/Item No.]
(Only the replacement  parts are described.)
1
Developer
Supply when installing
2
Doctor cover unit
[PG No.: [41] -11]
3
DV side plate F, R
{
{
{
{
{
{
{
Clean around the DV side seal F and R. 
4
DV duct cover
{
{
{
{
{
{
{
Clean the lower section of the MG roller.
5
DV side seal F, R
[PG No.: [41] - 27, [41] - 43]
6
DV BOX filter
[PG No.: [41] - 54]
7
DV filter unit
[PG No.: [42] - 1]
3
4
3
7
2
6
5
5
1
MX-M1100  MAINTENANCE  9 – 24
B. Details
1)
Open the front cover (a), and pull out the toner tray (b) a little. 
2)
Remove the screw (a), and remove the cover (b).
3)
Remove the blue screw (a), and remove the plate (b).
4)
Slide the developing unit (a) to the right, and pull it out until the
grip (b) can be held. 
5)
Hold the handle (a) of the developing unit, and lift it up to
remove completely. 
* When placing the developing unit, use the stand (b) and
place the unit on it.
6)
Clean the lower section (a) of the MG roller of the DV duct
cover at every 500K. 
a
b
a
a
b
a
a
a
b
a
b
b
a
a
Page of 86
Display

Click on the first or last page to see other MX-M950 / MX-MM1100 (serv.man40) service manuals if exist.