Firmware Upgrade
SHARP
Document Solution Centre
25
USB Device:
1. Insert a USB memory device containing the firmware file into the main USB Port.
2. Enter Simulation 49-01.
Note: “If no USB device is detected, an error message will be displayed.
3. Using the LCD screen, browse and select the updated engine firmware file (*.sfu):-
4. The current and the updated firmware versions will be shown within the display:-
5. Select the required firmware that requires updating - Press Execute & Yes to commence the
update.
Note: If all firmware (including peripherals) require updating, select ALL (as shown):-
Note: If all firmware (including peripherals) require updating, select ALL (as shown):-
Firmware Upgrade
26
SHARP
Document Solution Centre
6. Firmware update progress (and remaining time) should now be displayed:-
7. Once the firmware update has completed successfully, select OK (MFP should reboot).
Firmware update is complete.
Firmware Upgrade
SHARP
Document Solution Centre
27
Network (Web Page)
1. Open a web browser and enter the following URL :-
http://ipaddress/service_login.html or
http://ipaddress/service_account.html
Example: http://192.168.0.124/service_login.html
2. Select/Enter the “Service” Username and Password to access the Service Webpage and click
Login:-
Default
Username:
service
Password:
service
3. When the service webpage opens, click Update of Firmware:-
Firmware Upgrade
28
SHARP
Document Solution Centre
4. Click Browse to navigate to the location of the updated firmware file and select Open:-
5. Press Execute to start the firmware update.
Note: Once the machine has entered “service download mode”, the update will commence
and the progress will be displayed.
6. When the upgrade is complete, click Reboot to execute a remote restart of the machine.
Firmware Upgrade is complete.