Copying Equipment / MXM1204 Handy Guide Version 1.1 (Draft) December 2012 - NOTE - Handy Guides are NOT a substitute for Service Manuals and Parts Guides
File
mx-m904-mx-m1204-sm6.pdf
Date

Sharp MX-M904 / MX-M1204 (serv.man6) Handy Guide ▷ View online

 
MX-EB15 Mirroring Kit 
 
SHARP
 
Document Solution Centre
 
37 
 
 
When the mirroring kit is installed, the two HDD units are named HDD1 (Standard Machine HDD) and HDD2 
(Mirroring Kit HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the 
operation panel:- 
 
Mirroring Kit is installed. 
 
Mirroring Kit / HDD Trouble. 
 
Mirroring Kit / Rebuilding - Copying the whole contents of one HDD to the other HDD. 
 
 
Troubleshooting: 
 
Use SIM62-20 to check the HDD status, and refer to the following tables to confirm the relation between 
the HDD status and possible remedy :- 
 
Status & Trouble when             is displayed:-
 
 
SIM 62-20 
HDD2 
OK 
NONE 
REBUILDING 
ERROR 
TROUBLE 
HDD1 
OK 
– 
– 
NONE 
– 
– 
– 
– 
REBUILDING 
– 
– 
– 
– 
– 
ERROR 
– 
– 
– 
– 
TROUBLE 
– 
– 
– 
– 
 
 
Status & Trouble when E7-03 error message is displayed:- 
 
SIM 62-20 
HDD2 
OK 
NONE 
REBUILDING 
ERROR 
TROUBLE 
HDD1 
OK 
B or C 
NONE 
B or C 
REBUILDING 
ERROR 
TROUBLE 
D or E 
 
 
 
Cont’d 
 
 
 
MX-EB15 Mirroring Kit 
 
 
38 
SHARP
 
Document Solution Centre
  
 
 
Troubleshooting: 
 
Case 
Trouble 
Cause 
Advice 
One HDD status 
is OK. 
 
One HDD status is 
NG 
Connection failure of the 
connectors and harness of the 
mirroring kit 
•  Replace the HDD & perform the replacement 
procedure of the mirroring kit HDD. 
•  Replace the mirroring kit and perform the 
replacement procedure of the mirroring kit 
HDD. 
When at least one 
HDD is OK. 
•  Communication trouble 
through the SATA harness of 
HDD. 
•  Trouble of HDD which 
indicates the status other than 
OK. 
•  Broken data in HDD. 
•  RAID PWB trouble. 
•  Replace the cable. Remove and connect. 
•  Replace the HDD which indicates other than 
OK and perform the replacement procedure 
of the mirroring kit HDD or standard machine 
HDD. 
•  Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
When at least one 
HDD is NONE. 
•  Communication trouble 
through the SATA harness of 
HDD. 
•  Connection failure between 
the mirroring kit and the HDD. 
•  HDD trouble. 
•  HDD SATA harness & 
connector trouble. 
•  RAID PWB trouble. 
•  Replace the cable. Remove and connect. 
•  Check connection between the mirroring kit 
and the HDD. 
•  Replace the HDD which indicates NONE. 
Perform the replacement procedure of the 
mirroring kit HDD or standard machine HDD. 
•  Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
•  Replace both of the HDD of the mirroring kit 
and that of the machine. 
When in TROUBLE- 
TROUBLE. 
•  RAID PWB trouble 
•  (Both or one) HDD trouble 
•  Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
•  Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
When in TROUBLE- 
TROUBLE. 
(Occurring when 
replacing the HDD) 
•  The mirroring kit is composed 
of HDD's that have different 
mirroring information. (eg. A 
HDD which has been used in 
the mirroring kit of another 
machine is installed.) 
•  Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
Other than cases B, 
C, D, and E 
•  RAID PWB trouble. 
•  Both HDD’s trouble. 
•  Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
•  Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
 
 
 
MX-EB15 Mirroring Kit 
 
SHARP
 
Document Solution Centre
 
39 
 
 
HDD Replacement Procedure: 
 
Where possible, backup the HDD storage data before replacement:- 
 
• 
Use SIM56-02 or device cloning/storage backup function to backup the Address book, Image 
Send registration data and User authentication data to USB memory. 
 
• 
When using the MFP Web Page, back up the Document Filing data, Font, Macro and JOB LOG 
data to PC 
 
When there is FAX/Internet Fax received data present, use SIM66-62 to backup the image data to USB 
memory (PDF file), and then provide the PDF data to the user. (This data cannot be restored to the 
machine). 
 
Confirm that the UI icon which indicates “HDD trouble” is displayed. Use SIM62-20 to confirm the HDD 
status to determine which HDD is in trouble:- 
 
If HDD1 is in trouble, replace the HDD of the machine. 
 
If HDD2 is in trouble, replace the HDD of the mirroring kit. 
 
Power off the MFP device (Primary power switch). 
 
 
WHEN REPLACING THE MIRRORING KIT HDD ONLY:- 
 
1.  Using a new HDD unit from Service Spare Parts, replace the Mirroring Kit HDD. 
 
2.  Power on / Boot the MFP device:-  Rebuilding is automatically executed. 
 
3.  Check that E7-03 trouble does not occur, and the UI icon which indicates rebuilding of the 
mirroring kit is displayed. Use SIM 62-20 to confirm the status of the replaced HDD is displayed  
as REBUILDING. 
 
Note: It will take approx. three hours to complete HDD “rebuilding”. 
 
4.  Once REBUILDING is complete, use SIM62-20 to confirm that the HDD status is displayed as 
HDD1/HDD2=OK/OK. 
 
 
WHEN REPLACING BOTH THE MIRRORING KIT AND MACHINE HDDs TOGETHER:- 
 
1.  Using a new HDD units from Service Spare Parts, replace both HDD's (and RAID PWB if required). 
 
2.  Set DIPSW1 of the mirroring kit to ON:- 
 
 
 
 
 
3.  Power on the MFP device - Forcible rebuilding is executed. 
 
 
MX-EB15 Mirroring Kit 
 
 
40 
SHARP
 
Document Solution Centre
  
 
 
4.  Check that E7-03 trouble does not occur, and the UI icon which indicates rebuilding of the 
mirroring kit is displayed.  
 
5.  Execute SIM62-20 to confirm that the HDD status is displayed as HDD1/HDD2=OK/OK. 
 
6.  Power OFF the MFP device (Primary power switch) and set DIPSW1 to OFF. 
 
7.  Power ON the MFP Device 
 
8.  Clear the FAX/SCANNER image memory by executing SIM66-10:- 
 
This memory must be cleared for all models equipped with FAX/I-FAX and Network Scanner in order to 
keep compliance between the HDD data and the image related memory.  
 
9.  Install the E-Manual Data onto the HDD using SIM49-03. 
 
10. Install Watermark data onto the HDD using SIM49-05:- 
 
U2-60 trouble will be displayed when no Watermark data is present . After installing the 
Watermark data, reboot the MFP and cancel U2-60 trouble by executing SIM16. 
 
11. Import the storage data backed up in Step 1. 
 
•  Use SIM56-02 or device cloning/storage backup function to import the Address book, Image 
Send registration data and User authentication data etc. 
 
•  Import the Document Filing data, User font and macro data - (The JOB LOG data can be backed 
up but cannot be imported). 
 
 
Caution: 
 
• 
When replacing the HDD for the mirroring kit, ensure to use a new HDD unit. 
• 
If an HDD that has been previously used for a mirroring kit is used to replace a HDD, the 
operations and the data cannot be assured. 
• 
If an HDD that has been previously used for a mirroring kit is installed, the original data may be 
erased. 
• 
When removing the HDD after installing the mirroring kit, be sure to remove both HDD's 
together. 
• 
If only one HDD is removed and then reinstalled, the data of both HDD's may 
not be identical, causing an error. 
• 
When removing the HDD for maintenance reasons only, disconnect the HDD SATA connector of 
the MFP PWB first, and then perform the required maintenance. With this procedure, both 
HDD's are disconnected from the machine. 
 