Copying Equipment / MXM1204 Handy Guide Version 1.1 (Draft) December 2012 - NOTE - Handy Guides are NOT a substitute for Service Manuals and Parts Guides
File
mx-m904-mx-m1204-sm6.pdf
Date

Sharp MX-M904 / MX-M1204 (serv.man6) Handy Guide ▷ View online

 
Firmware Recovery 
 
SHARP
 
Document Solution Centre
 
29 
 
 
In the event of a power failure during a firmware update or when an error occurs within a section other 
than the boot program, the following recovery method can be performed to reinstall the ICU, SCU, PCU, 
FAX & Option firmware. 
 
However, if an abnormality occurs with the boot program, the SD card must be replaced with a new one 
(from service parts only) that contains the boot firmware. 
 
Menu Key Reference 
 
The following five keys are used to perform firmware recovery mode. For MX-6240/7040N series, touch 
the LCD panel within the area shown below to select the desired key:- 
 
 
 
 
 
 
    [UP]                          [BACK] 
 
 
 
 
 
 
             [DOWN]   
 
  [OK] 
       [MENU] 
 
Firmware Recovery Procedure:- 
 
1.  Power off the MFP. Remove the Right Rear Cabinet and 
Screws and pull out the MFP PWB. Turn ON  
MFP PWB UPDATE DIP SW
 
Note: If a Boot failure has occurred, replace the SC Card. 
 
2.  Insert a USB memory device containing the  
MX-M904/1204 series firmware file (SFU) into the USB slot. 
 
3.  Insert the MFP PWB and Turn ON the MFP Power. 
 
After approximately 10 seconds, UPDATE PROGRAM  
INIT PLEASE WAIT indication should be displayed. 
 
 
4.  VERSION CHECK: CONF: message will appear when 
Booting is complete. 
 
 
5.  Select the required Firmware Update mode by using 
the [MENU] and [BACK] keys. 
 
 
 
 
Version Check 
Conf: 00050000
 
Update Program Init 
Please wait
 
Firm Update 
    From USB Memory
 
Firmware Recovery 
 
 
30 
SHARP
 
Document Solution Centre
  
 
 
6.  Using the [UP] and [DOWN] keys, navigate and select  
the required firmware SFU file . 
 
 
 
Use the [OK] key to browse through to the sub folder(s) or  
 
 
[BACK] key to return to the parent folder(s). 
 
 
7.  Press [OK]. – It will take approx. 1-2 minutes to read the  
 
SFU file. 
 
 
8.  After reading is completed, the firmware update (writing)  
 
will commence. 
 
 
 
Note:   
 
 
The abbreviated name/location of the firmware that is being 
 
 
updated will appear in the upper right corner. 
 
9.  If the firmware upgrade completes successfully,  
 
RESULT OK will be displayed. 
 
10. Power off the MFP. Pull out the MFP PWB and 
Turn OFF MFP PWB UPDATE DIP SW
 
11. Insert and secure the MFP PWB and refit the Right Rear  
Cabinet. 
 
 
Firm Update 
> 0100h200.sfu
 
Firm Update 
    Reading Data
 
Firm Update           IcuM 
    Writing Data
 
Firm Update           IcuM 
    Result  :  OK
 
 
E-Manual Update 
 
SHARP
 
Document Solution Centre
 
31 
 
 
1.  Using a PC, copy the E-Manual Update onto the root of a USB memory device (as shown). 
 
Note:  The E-Manual firmware for MX-M904/1054/1204 series consists of 1 file (*.UAR). 
 
 
 
2.  Insert the USB memory device into a USB port on the machine and execute Simulation 
49-03 [E-MANUAL UPDATE]:- 
 
 
 
3.  Browse the E Manual Directory (eg MANUAL) and select the “*.uar” update file:- 
 
 
 
E-Manual Update 
 
 
32 
SHARP
 
Document Solution Centre
  
 
 
4.  The current and updated version should then be displayed:- 
 
 
 
5.  Press Execute to commence upgrade. Update File Checking and a progress of the update will 
be displayed:- 
 
 
 
6.  Once the update is complete, press OK to exit simulation mode:- 
 
 
 
 
E-Manual update is complete. 