DOWNLOAD Sharp MX-M904 / MX-M1204 (serv.man6) Service Manual ↓ Size: 1.9 MB | Pages: 76 in PDF or view online for FREE

Model
MX-M904 MX-M1204 (serv.man6)
Pages
76
Size
1.9 MB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / MXM1204 Handy Guide Version 1.1 (Draft) December 2012 - NOTE - Handy Guides are NOT a substitute for Service Manuals and Parts Guides
File
mx-m904-mx-m1204-sm6.pdf
Date

Sharp MX-M904 / MX-M1204 (serv.man6) Handy Guide ▷ View online

 
Density & Gradation Adjustment 
 
SHARP
 
Document Solution Centre
 
13 
 
 
Automatic Grey Balance Calibration - FACTORY MODE 
 
Note:  When adjusting grey balance adjustment before or after routine maintenance, always use the  
 
recommended paper (Mondi 90gsm or equivalent) for optimum image quality. 
 
HIGH DENSITY PROCESS CONTROL:
 
 
 
[Execute] 
 
   
  Sim 44-06 
 
 
HALFTONE PROCESS CONTROL:
 
 
 
[Execute] 
 
   
  Sim 44-26 
 
 
GREY BALANCE ADJUSTMENT:
 
 
 
 
 
   
  Sim 46-74 
[Engine & Printer] 
 
 
FACTORY MODE 
 
Place printed test pattern onto glass for both Copy &  
 
Printer  modes.
 
 
 
Manual Colour Calibration – SERVICE MODE 
 
HIGH DENSITY PROCESS CONTROL:
 
 
 
[Execute] 
 
   
  Sim 44-06 
 
 
HALFTONE PROCESS CONTROL:
 
 
 
[Execute] 
 
   
  Sim 44-26 
 
 
GREY BALANCE ADJUSTMENT:
 
 
 
 
 
   
  Sim 46-74 
[Engine & Printer] 
 
 
SERVICE MODE 
 
Place printed test pattern onto glass for both Copy & 
 
Printer  modes.
 
 
GREY BALANCE MANUAL ADJUSTMENT:
 
 
 
 
 
   
  Sim 46-21 
[for Engine] 
 
   
  Sim 67-25 
[for Printer] 
 
Adjust K (17 points) for Copy & Printer Modes.
 
 
 
Density & Gradation Adjustment 
 
 
14 
SHARP
 
Document Solution Centre
  
 
 
PRINTER DENSITY CHECK: 
 
 
 
 
   
  Sim 64-05 
[PCL Printer] 
 
   
  Sim 64-06 
[PS Printer] 
 
 
 
 
SERVICE TARGET SETTING: 
 
 
 
 
   
  Sim 63-07 
[for Engine] 
 
   
  Sim 67-27 
[for Printer] 
 
 
Scan Test Pattern to Register Custom Service Target 
 
 
 
DEFAULT SETTING (Service Mode): 
 
To return machine to “Standard” setting:- 
 
STANDARD SERVICE TARGET SETTING: 
 
 
[Execute] 
 
   
  Sim 63-08 
[for Engine] 
 
   
  Sim 67-28 
[for Printer] 
 
GREY BALANCE ADJUSTMENT: 
 
 
 
 
   
  Sim 46-74 
[Engine & Printer] 
 
 
SERVICE MODE 
 
Place printed test pattern onto glass for both Copy &  
 
Printer  modes.
 
 
 
Maintenance 
 
SHARP
 
Document Solution Centre
 
15 
 
 
Consumable Quick Reference Guide:- 
 
Total Maintenance 
500K 
1000K  1500K  2000K  2500K 
Process 
Drum 
MX-850GR 
 
 
Developer 
MX-900GV 
 
 
Developer Maintenance Kit 
MX-900DK 
 
 
 
 
 
Main Charge Kit 
MX-900MK 
 
 
 
 
 
Cleaning Blade Kit 
MX-900CB 
 
 
 
 
 
Paper Dust Removal Kit 
MX-900PD 
 
 
 
 
 
Filter Kit 
MX-900FL 
 
 
 
 
 
Waste Toner Collector 
MX-850HB 
 
 
 
 
 
Fuser 
Fuser Maintenance Kit 
MX-950KC 
 
 
 
 
 
Heat Roller Kit 
MX-950HK 
 
 
Web Cleaning Kit 
MX-950WC 
 
 
 
 
 
Transfer 
Transfer Belt Kit 
MX-900TT 
 
 
 
 
Maintenance Indications: 
 
TA 
Maintenance [All] Counter has reached specified limit
 
 
 
DK 
Black Drum (Counter) has reached  
the specified life. 
Replace OPC Drum 
Process 
Section 
(Drum) 
 
VK 
Black Developer (Counter) has reached 
the specified life. 
Replace Developer. 
Process 
Section 
(Developer) 
 
FK3 
Fuser Web Cleaning Counter has reached 
the specified limit.
 
Replace the Fuser Web 
Cleaning Kit. 
Fuser Section 
 
 
Starting Powder: 
 
The following starting powder should be applied to the relevant consumable item during maintenance:- 
 
Starting Powder 
OPC Drum 
Primary Transfer Belt 
MX-M904 
MX-M1054 
MX-M1204 
UKOG-0312FCZZ 
[Stearic Acid] 
UKOG-0312FCZZ 
[Stearic Acid] 
 
 
 
 
Maintenance 
 
 
16 
SHARP
 
Document Solution Centre
  
 
 
Interval Checklist 
 
500k 
1000k 
3000k  Process Section: 
 
 
 
 
x
 
 
 
Replace Developer [MX-900GV] 
x
 
 
 
Replace OPC Drum [MX-850GR] 
 
 
 
Replace Developer Maintenance Kit [MX-900DK]:- 
 
 
 
•  Doctor cover unit / DV seal. 
•  DV side seal F. 
•  DV side seal R. 
•  DV box filter. 
•  DV toner filter. 
 
 
 
Replace Cleaning Blade Kit [MX-900CB]:- 
 
 
 
•  Cleaning blade. 
•  Side seal F. 
•  Side seal R. 
•  Sub blade. 
•  Drum separation pawl x4 
•  Duct sheet. 
 
 
 
Relocate Drum Separation Pawl mounting position 
 
 
 
Clean Before-Transfer Discharge Lamp. 
 
 
 
Clean OPC Drum Surface Potential Sensor 
Use Blow Brush or Dry Cloth – DO NOT CLEAN with Vacuum Cleaner
 
 
 
 
Replace Main Charge Kit [MX-900MK]:- 
 
 
 
•  Charger wire x2. 
•  Screen grid. 
•  Charger cleaner. 
•  Charger cushion. 
•  Cleaner base guide. 
 
 
x
 
Clean Main Charger Case  
x
 
x
 
 
Replace Main Charger Case  
[PCASZ0326FCZ1]
 
x
 
x
 
 
Replace Process Unit Blade Side Seal Front 
[PSEL-0992FCZ1] 
and 
Rear  
[PSEL-0991FCZ1]
 
 
 
 
Replace Ozone Filter Kit  [MX-900FL] :- 
 
 
 
•  Ozone filter 
•  Outlet filter. 
x
 
 
 
Sim 24-05  
Clear Developer Print, Rotation & Day Counter 
 
 
(only when Developer is replaced) 
x
 
 
 
Sim 25-02  
Toner Concentration Adjustment 
 
 
(only when Developer is replaced)   
 
 
 
Sim 24-04 
Clear MAINTENANCE ALL Counter 
x
 
 
 
Sim 24-04 
Clear DRUM CRTG K Counter 
 
 
(only when OPC Drum is replaced)  
 
 
 
 
Sim 24-04 
Clear DRUM BLADE K Counter 
 
 
(only when Drum Cleaner Blade is replaced)  
 
 
 
Page of 76
Display

Click on the first or last page to see other MX-M904 / MX-M1204 (serv.man6) service manuals if exist.