Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man9) Service Manual ▷ View online
MX-4070N MX-FN30 (FINISHER) 13 – 4
D. Connection of the finisher to the main unit
1)
Fit the pin of the connection guide plate into the positioning hole of
the finisher.
the finisher.
E. Check of the height of the main unit and the
finisher
1)
Check that the hole on the protrusion of the connection guide
plate is located between the marking lines of the protrusion of the
finisher.
plate is located between the marking lines of the protrusion of the
finisher.
*If the hole is not located between the marking lines, perform the
height/skew adjustment.
height/skew adjustment.
F. Height/skew adjustment
1)
Open the front cover.
2)
Unscrew the screw (x1) and remove the wrench.
3)
Turn the fixing nut of the caster in the direction of the arrow as
shown with the wrench, and then loosen it.
shown with the wrench, and then loosen it.
4)
When adjusting the height, make adjustment at 4casters shown in
the picture.
the picture.
Adjust the height of the adjusting nut of the caster by turning it in
the direction of the arrow as shown. (When turning the adjusting
nut 360-degree, the height of the finisher changes about
1.75mm.)
the direction of the arrow as shown. (When turning the adjusting
nut 360-degree, the height of the finisher changes about
1.75mm.)
*For heightening the finisher: Turn the nut in [A] direction.
*For lowering the finisher: Turn the nut in [B] direction.
5)
When adjusting the skew, make adjustment at 2casters shown in
the picture.
the picture.
Adjust the skew of the adjusting nut of the caster by turning it in
the direction of the arrows as shown.
the direction of the arrows as shown.
*For skewing the finisher to the right side: Turn the nut in [A] direc-
tion.
tion.
*For skewing the finisher to the left side: Turn the nut in [B] direc-
tion.
tion.
Marking Line
Screw
[B]
[B]
[B]
[B]
[B]
[A]
[A]
[A]
[B]
MX-4070N MX-FN30 (FINISHER) 13 – 5
6)
After the adjustment, return the wrench to the original position.
G. Fixation of the lock slide plate
1)
Fix the lock slide plate with the screw (x1) (M3x6 S Tight).
Close the front cover of the finisher.
H. Connection of the harness
1)
Attach the connector of the finisher and fix it with the screw.
I.
Placing of the staple position label
1)
Place the staple position label (for scanner)
2)
Place the staple position label (for RSPF)
J. Power-ON of the main unit
1)
Insert the power plug into the socket, and turn ON the main power
switch and the power switch of the operation panel.
switch and the power switch of the operation panel.
[B]
[A]
[A]
[B]
Screw
M3×6 S-tight
Ĭ
ĭ
)LWZLWKWKHFRUQHU5
)LWZLWKWKHFRUQHU5
/DEHODWWDFKPHQWUHIHUHQFH
&RUQHURIWKHXSSHU
FDELQHWERWWRP
MX-4070N MX-FN31 (SADDLE STITCH FINISHER) 14 – 1
MX-4070N
Service Manual
[14] MX-FN31 (SADDLE STITCH FINISHER)
1. Unpacking
A. Packed items check
B. Removal of the finisher
NOTE: It is recommendable to work by two or more persons.
1)
Open the box, and take out the accessary boxes, packed items,
and cushioning materials.
and cushioning materials.
2)
While holding the upper parts of the main unit and lifting the one
side of the machine, remove the cushioning materials. At this
time, be sure to hold up the plastic bag of the lifting side.
side of the machine, remove the cushioning materials. At this
time, be sure to hold up the plastic bag of the lifting side.
3)
While holding the upper parts of the main unit and lifting the oppo-
site side of Step.2), remove the cushioning materials and the plas-
tic bag.
site side of Step.2), remove the cushioning materials and the plas-
tic bag.
4)
Remove the slope plates (x2) and the fixing pins (x2). Fixing pins
are attached to the slope plate with the tape.
are attached to the slope plate with the tape.
5)
Align the line on the pallet and the arrow mark on the slope plate,
and mount the slope plates (x2) to the pallet with the screws (x2).
and mount the slope plates (x2) to the pallet with the screws (x2).
6)
Put the casters of the main unit on the slope plates, and then
slowly move the main unit to the floor.
slowly move the main unit to the floor.
No.
Name
Quantity
1
Connection guide plate
1
2
Interface pass guide
1
3
Earth plate
1
4
Stapler unit staple case
1
5
Screw (M4× 14 S- tight)
4
6
Screw (M3× 6 S- tight)
5
7
Staple position label (for scanner)
1
8
Staple position label (for RSPF)
1
1
2
3
4
5
6
7
8
MX-4070N MX-FN31 (SADDLE STITCH FINISHER) 14 – 2
C. Removal of the fixing tape and protection
material
1)
Remove all fixing tapes/protection materials from the exterior.
2)
Open the front upper cover. Remove all tapes and take out the
protection materials from the stapler section.
protection materials from the stapler section.
3)
Close the front upper cover.
Ĭ
ĭ
Į
į
į
İ
ı
IJ
ij
Click on the first or last page to see other MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man9) service manuals if exist.