MX-4070N  MX-RB25 (PAPER PASS UNIT)  9 – 2
3.  Installation
1)
Pull out the paper tray1, and remove the screw (x1) fixing the left
cabinet.
2)
Open the front cabinet, and remove the screw (x1) fixing the left
cabinet.
3)
Pull out the grip at the left side of the main unit, and remove the
left cabinet while sliding it to the front side.
4)
Remove the left cabinet upper from the left cabinet.
MX-4070N  MX-RB25 (PAPER PASS UNIT)  9 – 3
5)
Mount the left cabinet, and fix it with the screws (x2).
6)
Put the grip back to the original position
Close the paper tray1.
7)
Remove four lower kick-out sponge rollers.
Be sure not to leave the pieces of the sponge.
8)
Adjust the front and rear position of the shifter by aligning the
edge of the recessed part with the triangular marking position.
9)
Mount the interface unit from the left side of main unit while sliding
it on the basis of the back side.
MX-4070N  MX-RB25 (PAPER PASS UNIT)  9 – 4
10) Fix the interface unit with the screws (Packed items No.2   x2).
11) Fix the interface unit with the screws (Packed items No.3   x2).
12) Close the front cabinet.
13) Affix base resting cushion on back side of reverse gate tray.
14) Attach the reverse gate tray (Packed item No.6)
15) Remove the connector cover of the rear side of the main unit.
0mm
2.0mm
2.0mm
0mm
Reference position
(Hole edge face)
Reference position (Hole edge face)
Ĭ
1
: ‘16/Feb.
1
2
: ‘16/Apr.
2
MX-4070N  MX-RB25 (PAPER PASS UNIT)  9 – 5
16) Cut the section where the harness gets through with the nipper.
17) Secure the harness of the interface unit with the screw (Packed
items No.3   x1), and connect the connector.
18) Remove two screws of the rear cabinet of the main unit and attach
the step screw at one place.
19) Fix it with the screw.
20) Insert the harness fixing plate to the groove of main unit and fix
the harness fixing plate with the screw B (Packed items No.3).
21) Connect the connector to the PWB.
22) Pass the harness of the relay unit through the wire saddle.
23) Secure the connector cover with the screw (x1). 
Remove two screws
Fix it with the screwB
(Packed items No.3)
Fix it with the screwC
(Packed items No.4)
Screw B(No.3)
Insert the harness fixing plate to
the groove of main unit.
Connect the connector to the PWB.