DOWNLOAD Sharp MX-2630 Service Manual ↓ Size: 66.16 MB | Pages: 127 in PDF or view online for FREE

Model
MX-2630
Pages
127
Size
66.16 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Install Manual
File
mx-2630.pdf
Date

Sharp MX-2630 Service Manual ▷ View online

MX-2630N  MX-PN15B/C/D (PUNCH MODULE)  12 – 9
38) Pass the harness through the wire saddle.
39) Tie the harness, and pass it through the wire saddle so that it can
be fixed tightly.
40) Install the rear cabinet of the finisher with the screw.
41) Insert the hopper from the front side of the finisher, and push the
hopper as far as it goes.
42) Cut the cover section of the finisher shown in the figure below with
the nipper.
43) For MX-FN29 (Saddle finisher), connect the interface connector
connected to the inner cover.
MX-2630N  MX-PN15B/C/D (PUNCH MODULE)  12 – 10
44) Install the inner cover of the finisher with the screw.
45) Install the knobs (x2).
46) For MX-FN29 (Saddle finisher), also install the knob shown in the
figure below.
47) After installing the finisher to the main unit, fix the position shown
in the figure below with the screw. (Use the screw removed at
Step 11.)
48) Close the front door of the finisher.
49) Fix the harness section of the interface unit, and connect the har-
ness.
MX-2630N  MX-PN15B/C/D (PUNCH MODULE)  12 – 11
50) Fix the connector cover with the screw.
B. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet, and
turn ON the main power switch and the operation panel power
switch.
MX-2630N  MX-FN30 (FINISHER)  13 – 1
MX-2630N
Service Manual
 
[13] MX-FN30 (FINISHER)
1.  Unpacking
A. Packed items check
B. Removal of the finisher
NOTE: It is recommendable to work by two or more persons.
1)
Open the box, and take out the accessary boxes, packed items,
and cushioning materials.
2)
While holding the upper parts of the main unit and lifting the one
side of the machine, remove the cushioning materials. At this
time, be sure to hold up the plastic bag of the lifting side.
3)
While holding the upper parts of the main unit and lifting the oppo-
site side of Step.2), remove the cushioning materials and the plas-
tic bag.
4)
Remove the slope plates (x2) and the fixing pins (x2). Fixing pins
are attached to the slope plate with the tape.
5)
Align the line on the pallet and the arrow mark on the slope plate,
and mount the slope plates (x2) to the pallet with the screws (x2).
6)
Put the casters of the main unit on the slope plates, and then
slowly move the main unit to the floor.
No.
Name
Quantity
1
Connection guide plate
1
2
Interface pass guide
1
3
Earth plate
1
4
Stapler unit staple case
1
5
Screw (M4× 14 S- tight)
4
6
Screw (M3× 6 S- tight)
5
7
Staple position label (for scanner)
1
8
Staple position label (for RSPF)
1
1
2
3
4
5
6
7
8
Page of 127