3-11
3
Replacing Fiery AR-PE2 board components
To remove the fan cable, gently pull the cable connector straight out from the on-board 
connector (see the following figure).
F
IGURE
 3-5
CPU Cooling Unit
8.
Turn the board over so that the component side lay on the flat surface and dislodge each 
cooling unit pin from the hole in the board. 
Use your fingers or needlenose pliers to squeeze the slotted tip of each cooling unit pin 
and push the pin through the hole. Make sure the pins remain connected to the cooling 
unit.
N
OTE
:
Make sure not to apply excessive pressure on the board. When using needlenose 
pliers, orient the pliers perpendicular to the board to keep from scraping any board 
components or circuitry.
9.
Remove the CPU cooling unit, noting its orientation on the CPU.
CPU
CPU fan cable
CPU fan connector 
CPU cooling unit
(fan and heatsink)
3-12
3
Service Procedures
T
O
 
REPLACE
 
THE
 CPU 
COOLING
 
UNIT
1.
Position the CPU cooling unit over the CPU in the same orientation as when it was 
removed.
Orient the cooling unit so that the fan cable will not be stretched when connected to the 
on-board connector J300.
2.
Attach the CPU cooling unit to the board by pushing each of the four pins through the 
hole so that the lip of each pin snaps into place on the bottom of the board.
Make sure not to apply excessive pressure on the board.
3.
Plug the CPU fan cable into the 3-pin board connector J300. 
The fan cable connector is keyed to ensure proper connection.
4.
Reassemble the Fiery AR-PE2 and verify functionality.
See “Restoring Fiery AR-PE2 functionality after service” on page 3-19. 
DIMMs
Each DIMM (dual in-line memory module) is held in place by levers at each end of its 
socket on the Fiery AR-PE2 board. See Figure 3-6. In the initial configuration, DIMM 
slot J48 holds one 128MB DIMM and DIMM slot J49 is empty. Approved DIMMs are 
available from your authorized sales or service support center.
T
O
 
REPLACE
 
OR
 
UPGRADE
 
A
 DIMM
1.
To release a DIMM, push outward on the lever on each side of the DIMM. 
See the following figure.
3-13
3
Replacing Fiery AR-PE2 board components
F
IGURE
 3-6
Releasing a DIMM
2.
Slide the DIMM out of the socket at the same angle as the socket and set it aside. 
3.
To install a DIMM, slide it into the socket at the same angle as the socket. Push the 
DIMM into the socket until the levers snap into place.
Make sure that the levers close securely around the ends of the DIMM and that the 
DIMM is fully seated in its socket. Avoid flexing the board while you firmly seat the 
DIMM in its socket. The DIMM fits the socket only one way. The two notches on the 
bottom of the DIMM should line up with the notches in the socket. 
4.
Reassemble the unit and verify functionality.
See “Restoring Fiery AR-PE2 functionality after service” on page 3-19. 
To verify memory capacity, print a Configuration page to check the amount of memory 
recorded under Server Info.
Lever
DIMM
Socket notches
Lever
3-14
3
Service Procedures
Battery
The battery on the Fiery AR-PE2 board is located at BT200, near the DIMMs. To 
replace it, use a 3V manganese dioxide lithium coin cell battery (Panasonic CR2032 or 
equivalent).
CAUTION:  Explosion may occur if the battery is replaced with the incorrect type. 
Replace only with the same type recommended by the manufacturer. Dispose of used 
batteries according to the manufacturer's instructions.
ACHTUNG:  Es besteht Explosionsgefahr, wenn die Batterie durch eine Batterie falschen Typs ersetzt wird. Als Ersatz dürfen 
nur vom Hersteller empfohlene Batterien gleichen oder ähnlichen Typs verwendet werden. Verbrauchte Batterien müssen 
entsprechend den Anweisungen des Herstellers entsorgt werden.
ATTENTION:  Il y a risque d'explosion si la pile est remplacée par un modèle qui ne convient pas. Remplacez-la uniquement par 
le modèle recommandé par le constructeur. Débarrassez-vous des piles usées conformément aux instructions du constructeur.
ADVARSEL!: Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering Udskiftning må kun ske med bat-teri af samme fabrikat 
og type. Levér det brugte batteri tilbage til leverandøren.
VAROITUS: Paristo voi räjähtää, los se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan 
tyyppiin. Hävitä Käytetty paristo valmistajan ohjeiden mukaisesti.
ADVARSEL: Eksplosjonsfare ved feilaktig skifte av batteri. Benytt samme batteritype eller en tilsvarende type anbefalt av 
apparatfabrikanten. Brukte batterier kasseres i henhold til fabrikantens instruksjoner.
VARNING: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av 
apparat-tillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
T
O
 
REPLACE
 
THE
 
BATTERY
1.
Locate the battery on the Fiery AR-PE2 (see Figure 3-4 on page 3-9).
2.
Carefully lift the clip that holds the battery. 
Use caution when lifting up the clip; excessive force could cause the clip to lose its 
tension.
F
IGURE
 3-7
Fiery AR-PE2 battery
3.
Pull the battery out of its socket and release the clip.
4.
To insert a new battery, slide the battery into the socket under the clip with the positive 
(+) side facing up. 
Make sure the clip holds the battery securely in the socket.
5.
Reassemble the Fiery AR-PE2 and verify functionality.
See “Restoring Fiery AR-PE2 functionality after service” on page 3-19. 
The date and time of day are lost when the old battery is removed. See the Configuration 
Guide
 for instructions on entering Server Setup to program the system date and time.
Clip
Battery
Socket
+