DOWNLOAD Sharp AR-PE2 (serv.man6) Service Manual ↓ Size: 521.08 KB | Pages: 62 in PDF or view online for FREE

Model
AR-PE2 (serv.man6)
Pages
62
Size
521.08 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR-PE2 EFI Service Manual.
File
ar-pe2-sm6.pdf
Date

Sharp AR-PE2 (serv.man6) Service Manual ▷ View online

3-7
3
Checking connections
T
O
 
CONNECT
 
THE
 F
IERY 
AR-PE2 
TO
 
A
 PC
N
OTE
:
Make sure the PC meets the minimum requirements for installing system software 
specified in Getting Started.
1.
Shut down the Fiery AR-PE2 (see page 3-1) and power off the copier before connecting 
the Fiery AR-PE2 to a PC. 
2.
Power off the PC.
3.
Connect a parallel (Centronics) cable to the 36-pin mini-Centronics connector on the 
Fiery AR-PE2 (see Figure 3-2 on page 3-4).
4.
Connect the other end of the parallel cable to the parallel port of the PC.
If there is more than one parallel port connector on the back of the PC, ask the network 
administrator to indicate the preferred parallel port to use for the copier.
5.
Power on the PC and the copier.
6.
Configure Setup options. 
It is the network administrator’s responsibility to configure Setup according to the 
network and user environment. Default settings in Setup may be adequate although they 
may not be optimal for the user’s environment. Refer the network administrator to the 
Configuration Guide for Setup information.
7.
After configuring Setup options, verify the parallel port connection.
Once the parallel port connection has been made and the Fiery AR-PE2 has the correct 
Setup configuration and is Idle, the network administrator should print a few test 
documents from the PC connected to the copier. See the Configuration Guide for more 
information.
Once you conclude that all external connections are good, check the internal 
connections.
To service the Fiery AR-PE2, you need to shut down and remove the Fiery AR-PE2 from 
the copier. See the AR-PE2 Installation Manual for removal instructions.
3-8
3
Service Procedures
Fiery AR-PE2 assembly
The custom Fiery AR-PE2 board has a Celeron CPU that controls the video image data 
transferred to and from the copier. The Fiery AR-PE2 board provides the Ethernet 
networking interface, controls hard disk drive functions, and handles the communication 
between the Fiery AR-PE2 and external devices. It has two DIMM sockets that hold a 
total memory of 128MB (upgradable to 256MB). See Figure 3-4 on page 3-9 and also 
“DIMMs” on page 3-12.
When you remove the cover plate from Fiery AR-PE2, you will find the Fiery AR-PE2 
board and its on-board HDD. The Fiery AR-PE2 board is attached to the chassis. You do 
not need to remove the Fiery AR-PE2 board to replace parts (except for the CPU cooling 
unit and the chassis fan) on the Fiery AR-PE2. 
Following are instructions for accessing, removing, and replacing Fiery AR-PE2 board 
components, including the CPU cooling unit, DIMMs, battery, and HDD.
Make sure to attach an ESD grounding wrist strap and follow standard ESD 
(electrostatic discharge) precautions before following these procedures.
3-9
3
Fiery AR-PE2 assembly
F
IGURE
 3-4
Fiery AR-PE2 board
Key
1. HDD
8. Video interface connector (J813)
2. CPU fan cable connector
9. Parallel connector (J771)
3. CPU with cooling unit
10. 10/100BaseTX connector (J772)
4. HDD connector
11. Network Status LEDs (see page 1-2)
5. DIMM in socket J48
12. Chassis fan
6. DIMM socket J49 (not visible)
7. Battery (not visible)
1
2
3
4
5
7
9
10
8
11
6
12
3-10
3
Service Procedures
Replacing Fiery AR-PE2 board components
This section describes how to remove and replace the following parts on the 
Fiery AR-PE2 board:
• CPU cooling unit 
• DIMMs
• Battery 
• HDD (hard disk drive) 
• Chassis fan
CPU cooling unit
A fan attached to the CPU heatsink runs continuously when the copier is on. 
T
O
 
REMOVE
 
THE
 CPU 
COOLING
 
UNIT
1.
Shut down the Fiery AR-PE2 (see page 3-1) and power off the copier. 
2.
Remove the Fiery AR-PE2 assembly from the copier as described in the AR-PE2 
Installation Manual
3.
Remove the chassis fan cable from board connector J301 (see Figure 3-1 on page 3-2).
4.
Remove the five mounting screws that secure the Fiery AR-PE2 board to the chassis. 
5.
Release the Fiery AR-PE2 board from the three metal standoffs at the base of the 
chassis.
6.
Remove the Fiery AR-PE2 board from the chassis and lay the Fiery AR-PE2 board on a flat 
anti-static surface. 
7.
Unplug the CPU fan cable from board connector J300.
Page of 62