3-3
3
Checking connections
Checking connections
The most common causes of hardware problems are faulty or loose connections. This 
section describes internal connections from the copier to the Fiery AR-PE2, external 
connections on the Fiery AR-PE2, and internal connections in the Fiery AR-PE2 
assembly.
T
O
 
CHECK
 
CONNECTIONS
1.
Attach an ESD grounding wrist strap, shut down the Fiery AR-PE2 (see page 3-1), and 
power off the copier. 
2.
Inspect internal ribbon cables to see if they are intact.
Faulty ribbon cables are easily overlooked. Check the contact point between the cable 
and the connector to ensure that they have not separated. If a ribbon cable is suspect, 
substitute it with a tested cable.
3.
Make sure that all cables and DIMMs are properly aligned and well seated on their 
Fiery AR-PE2 connectors. For connector and DIMM socket locations on the Fiery AR-PE2, 
see Figure 3-4 on page 3-9. 
4.
Check the HDD connection to the Fiery AR-PE2 connector J207. If the 4 screws are 
installed properly from the Fiery AR-PE2 into the HDD, the connection is secure.
5.
After tightening connections, if one or more Fiery AR-PE2 components are still not 
getting power at power up, you may need to check the copier power supply.
T
ABLE
 3-1
Fiery AR-PE2 cable connections within the copier
From
To
Copier power supply
Power connector on Fiery AR-PE2 (J812)
Copier video interface
Video interface connector on Fiery AR-PE2 (J813)
Operation Panel
Video interface connector on Fiery AR-PE2 (J813)
CPU fan on Fiery AR-PE2
CPU fan connector on Fiery AR-PE2 (J300)
Chassis fan
Chassis fan connector on Fiery AR-PE2 (J301)
3-4
3
Service Procedures
Verifying connection to the network
The Fiery AR-PE2 provides twisted pair connectivity to an Ethernet network. This 
section describes how to connect the Fiery AR-PE2 to the network and print a few test 
documents in order to verify the connection.
Category 3 or Category 5 unshielded twisted pair (UTP) network cable can be used for 
10BaseT. Category 5 cable is required for 100BaseTX.
F
IGURE
 3-2
Fiery AR-PE2 network connector
10BaseT/100BaseTX connector
for twisted pair Ethernet
3-5
3
Checking connections
T
O
 
CONNECT
 
A
 
TWISTED
 
PAIR
 
CABLE
 
TO
 
THE
 F
IERY 
AR-PE2
Category 5 unshielded twisted pair (UTP) network cable must be used for 100BaseTX. It 
connects to the RJ-45 connector on the Fiery AR-PE2 (see Figure 3-2 on page 3-4).
1.
Shut down the Fiery AR-PE2 (see page 3-1) and power off the copier before connecting 
the Fiery AR-PE2 to any network device.
2.
Connect the network cable to the RJ-45 connector on the Fiery AR-PE2 (see Figure 3-2 
on page 3-4).
3.
Configure Setup options. 
It is the network administrator’s responsibility to configure Setup according to the 
network and user environment. Default settings in Setup may be adequate although they 
may not be optimal for the user’s environment. Refer the network administrator to the 
Configuration Guide for Setup information.
4.
After configuring Setup options, verify the network connection.
Once the network connection has been made and the Fiery AR-PE2 has the correct 
Setup configuration and is Idle, the Fiery AR-PE2 should be available on the network.
The network administrator should perform any additional network Setup, verify the 
network connection, verify that the Fiery AR-PE2 appears in the list of printers, and 
print a few test documents from a networked computer that will use the Fiery AR-PE2. 
(See the Configuration Guide for more information.) 
3-6
3
Service Procedures
Verifying the parallel port connection
On the Fiery AR-PE2, the parallel connector (female 36-pin mini-Centronics) provides a 
high-speed interface port for connecting directly to the parallel port of a PC. The parallel 
port can be used for installing system software (see page 3-20). 
The Fiery AR-PE2 can be connected to the network and to a parallel port device at the 
same time. See Figure 3-2 on page 3-4.
An IEEE 1284 bi-directional cable is required. One end of the cable requires a male 
IEEE 1284-C (36-pin mini-Centronics) connector for connecting to the Fiery AR-PE2. 
N
OTE
:
For optimal performance, use a short cable. Longer cables may cause erroneous 
operation.
F
IGURE
 3-3
Fiery AR-PE2 parallel port connector
Parallel port connector
Page of 62