Sharp AR-FX7 Service Manual ▷ View online
AR-FX7 SOFT SWITCH 7 - 2
2. Soft SW list
∗
When a value outside the set range is inputted, the default is automatically set.
∗
Never change the switch whose item is specified as inhibition.
∗
: UK = U.K.,
G = Germany,
F = France
Reception print Paper selection
Judgment of sub scan length None
When printing is not made on desired paper
Output condition setup
Reception
function setup
function setup
When divided print instead of reduction print
is required
is required
Automatic reduction print
Reception
function setup
function setup
When reduction print is not made
Magnification ratio in
automatic reduction
automatic reduction
None
When reduction print is not made on a fixed
size paper
size paper
Rotation reception print
None
When rotation print is not made
Reception size setup
Reception
function setup
function setup
The reception capacity is displayed on the
transmitter.
transmitter.
Index
Index print setup
Reception
function setup
function setup
SW 40-4
When an index is attached to the reception
data
data
Large item
Middle item
Switch content
Key operator
Soft SW No.
Usage
SW
No.
No.
Data
No.
Items
SW selection and functions
Default value
∗
Remarks
UK G
F
S
W
1
1
Country information
Binary
input
Bit No.
1
2
3
4
5
6
7
8
Japan (00000000)
U.S.A. / Canada (10110101)
Australia (00001001)
U.K. (10110100)
France (00111101)
Germany (00000100)
Sweden (10100101)
New Zealand (01111110)
China (00100110)
Singapore (10011100)
Taiwan (11111110)
Middle East (11111101)
Malaysia (01101100)
India (01010011)
Hong Kong (01010000)
Spain (10100000)
Portugal (10001011)
Italy (01011001)
Switzerland (10100110)
Finland (00111100)
Denmark (00110001)
Norway (10000010)
Netherlands (01111011)
Luxembourg (01101001)
Belgium (00001111)
U.S.A. / Canada (10110101)
Australia (00001001)
U.K. (10110100)
France (00111101)
Germany (00000100)
Sweden (10100101)
New Zealand (01111110)
China (00100110)
Singapore (10011100)
Taiwan (11111110)
Middle East (11111101)
Malaysia (01101100)
India (01010011)
Hong Kong (01010000)
Spain (10100000)
Portugal (10001011)
Italy (01011001)
Switzerland (10100110)
Finland (00111100)
Denmark (00110001)
Norway (10000010)
Netherlands (01111011)
Luxembourg (01101001)
Belgium (00001111)
The initial value
differs
depending on
the destination.
1
0
0
2
0
0
0
3
1
0
1
4
1
0
1
5
0
0
1
6
1
1
1
7
0
0
0
8
0
0
1
S
W
2
1
SIM language
information
information
Bit No.
1
2
English
0
0
0
Japanese
0
0
2
English
0
1
0
0
0
3
Language information
Binary
input
Bit No.
3
4
5
6
7
8
1: English
3: French
4: German
5: Italian
6: Dutch
7: Swedish
8: Spanish
9: Portuguese
3: French
4: German
5: Italian
6: Dutch
7: Swedish
8: Spanish
9: Portuguese
16: Finnish
The initial value
differs
depending on
the destination.
0
0
0
For English, the
proper character
is determined by
destination
information.
proper character
is determined by
destination
information.
4
0
0
0
5
0
0
0
6
0
1
0
7
1
0
1
8
0
0
1
AR-FX7 SOFT SWITCH 7 - 3
SW
No.
No.
Data
No.
Items
SW selection and functions
Default value
Remarks
S
W
3
1
Sharp machine mode
1: ON
0: OFF
ON
1
2
Sharp machine mode (F
code)
code)
1: ON
0: OFF
OFF
0
3
FAST mode
1: Yes
0: No
No
0
SEC only
4
Center No. in FAST mode
1: Host-Tel-No.
0: Service-No.
Service-No.
0
5
Maintenance cycle
Bit No.
5
6
7
75K
0
Functions in FAST
operation.
operation.
75K
0
0
1
50K
0
1
0
6
25K
0
1
1
0
20K
1
0
0
10K
1
0
1
7
5K
1
1
0
1
Free except for the
above.
above.
8
Maintenance system
1: DM
0: AR
AR
0
S
W
4
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
5
1
Initialization control inside
program
program
1: The all soft switches are
initialized.
initialized.
0: Does nothing.
Does nothing.
0
Used to restrict
initialization inside
the program. (Use
inhibited)
initialization inside
the program. (Use
inhibited)
2
For FAX debug
1: Debug mode ON
0: Debug mode OFF
Debug mode OFF
0
3
Flash memory check
measuring range
measuring range
1: All areas
0: 256byte
256byte
0
4
ICU UART1 output
1: Not output
0: Output
Not output
1
5
24V reset wait time
Binary
input
Bit No.
Setting range
Setting range
5
6
7
8
0 to 750ms
500ms
1
6
0
7
1
8
0
S
W
6
1
Auto/Manual default setup
1: Manual reception
0: Automatic reception
Automatic
reception
0
Manual receive
setting is enabled
only when an
external telephone
is connected.
setting is enabled
only when an
external telephone
is connected.
2
Inhibited to use
0
3
Size specification
Bit No.
3
4
Follows the
machine
information.
0
When setting is
made to follow the
machine
information, if the
machine information
is incomplete, the
paper size is set to
the centimeter size.
made to follow the
machine
information, if the
machine information
is incomplete, the
paper size is set to
the centimeter size.
Centimeter size
0
0
Inch size
1
0
4
Follows the
machine
information.
machine
information.
0
1
1
Follows the
machine
information.
machine
information.
1
1
5
Inhibited to use
0
6
Memory transmission/
direction transmission
default setup
direction transmission
default setup
1: Direct transmission
0: Memory transmission
Memory
transmission
0
7
Quick memory transmission 1: Allowed
0: Inhibited
Allowed
1
8
Remote reception instruction 1: Yes
0: No
Yes
1
S
W
7
1
Remote selection number
setup
setup
Binary input
5
0
When a value
outside the setting
value range is
inputted, the initial
value is set.
outside the setting
value range is
inputted, the initial
value is set.
2
Bit No.
Setting range
Setting range
1
2
3
4
5
6
7
8
0 to 9 times
0
3
0
4
0
5
0
6
1
7
0
8
1
AR-FX7 SOFT SWITCH 7 - 4
S
W
8
1
Image quality priority
selection
selection
Bit No.
1
2
3
Standard
0
Standard
0
0
0
Fine
0
0
1
2
Super fine
0
1
0
0
Ultra fine
0
1
1
Not used
1
0
0
3
Fine
1
0
1
0
Super fine + half
tone
tone
1
1
0
Ultra fine + half tone 1
1
1
4
Density default setup
Bit No.
4
5
6
7
8
Automatic
0
Automatic
0
0
0
0
0
5
Light
1
0
0
0
0
0
Slightly light
0
1
0
0
0
6
Middle
0
0
1
0
0
0
7
Slightly dark
0
0
0
1
0
0
8
Dark
0
0
0
0
1
0
S
W
9
1
Inhibited to use
1
2
Transfer function
1: Allowed
0: Inhibited
Allowed
1
3
Relay broadcast function
1: Allowed
0: Inhibited
Allowed
1
4
Inhibited to use
0
5
0
6
Cover function default setup
1: Yes
0: No
No
0
7
Specified number receive
reject
reject
1: Reject
0: Not reject
Not reject
0
8
Specified number receive
reject I manual receive
reject I manual receive
1: Reject
0: Not reject
Reject
1
S
W
10
1
F-code relay broadcast
function
function
1: Inhibited
0: Allowed
Allowed
0
2
F-code confidential reception 1: Inhibited
0: Allowed
Allowed
0
3
Yes/No of SUB capacity in
reception
reception
1: No
0: Yes
Yes
0
4
Yes/No of SEP capacity in
reception
reception
1: Inhibited
0: Allowed
Allowed
0
5
Yes/No of reception PWD
capacity
capacity
1: Inhibited
0: Allowed
Allowed
0
6
Yes/No of SID capacity in
reception
reception
1: Inhibited
0: Allowed
Allowed
0
7
Judgment of the system
number of bulletin board
transmission
number of bulletin board
transmission
1: Allowed
0: Inhibited
Inhibited
0
8
Send request protection
1: Not protected
0: Protected
Protected
0
S
W
11
1
Inhibited to use
0
2
0
3
Sender’s telephone number
registration
registration
1: No
0: Yes
Yes
0
4
Yes/No of manual send
selection menu display
selection menu display
1: Displayed
0: Not displayed
Displayed
1
5
Inhibited to use
0
6
0
7
0
8
0
S
W
12
1
Direct send recall Allow/
Inhibit
Inhibit
1: Allowed
0: Inhibited
Inhibited
0
2
Manual/Auto reception auto
swiching
(Inhibited except for France.)
swiching
(Inhibited except for France.)
1: Allowed
0: Inhibited
Inhibited
0
3
Number of auto switch calls
of manual reception
of manual reception
→
auto
reception
(Inhibited except for France.)
(Inhibited except for France.)
Binary
input
Bit No.
Setting range
Setting range
3
4
5
6
1 to 9 times
9 times
1
When the value is
outside the setting
range, the initial
value is set.
outside the setting
range, the initial
value is set.
4
0
5
0
6
1
7
Inhibited to use
0
8
Remote selection models
1: Both call-in and call-out
0: Call-in only
Call-in only
0
SW
No.
No.
Data
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7 SOFT SWITCH 7 - 5
S
W
13
1
Recall times in busy
Binary
input
Bit No.
Setting range
Setting range
1
2
3
4
0 to 10 times
2 times
0
When the value is
outside the setting
range, the initial
value is set.
outside the setting
range, the initial
value is set.
2
0
3
1
4
0
5
Recall interval in busy
Binary
input
Bit No.
Setting range
Setting range
5
6
7
8
1 to 15 min
3 min
0
When the value is
outside the setting
range, the initial
value is set.
outside the setting
range, the initial
value is set.
6
0
7
1
8
1
S
W
14
1
Recall number in case of a
transmission error
transmission error
Binary
input
Bit No.
Setting range
Setting range
1
2
3
4
0 to 5 times
1 times
0
When the value is
outside the setting
range, the initial
value is set.
outside the setting
range, the initial
value is set.
2
0
3
0
4
1
5
Recall interval in
communication error
communication error
Binary
input
Bit No.
Setting range
Setting range
5
6
7
8
0 to 15 min
0: Recall immediately after
cutting the line
0: Recall immediately after
cutting the line
1 min
0
When the value is
outside the setting
range, the initial
value is set.
outside the setting
range, the initial
value is set.
6
0
7
0
8
1
S
W
15
1
Inhibited to use
0
2
0
3
0
4
Signal send level
Binary
input
Bit No.
Setting range
Setting range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
–8dBm
0
5
1
6
0
7
0
8
0
S
W
16
1
Modem speed (V.33 mode or
less)
less)
Bit No.
1
2
3
4
V.17 14.4kbps
1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0
V.17 14.4kbps
Other than the
above
above
5
Modem speed in reception
fixed
fixed
Bit No.
5
6
No fixing
0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0
V.17-14400BPS
1
1
7
EOL detection timer
1: 25sec
0: 13sec
13sec
0
8
RTN EOL send times
1: 6 times
0: 12 times
6 times
1
S
W
17
1
Inhibited to use
0
2
MH fixed (except for SG3)
1: Yes
0: None (depending on the
remote machine)
remote machine)
No
0
3
ECM MMR mode (except for
SG3)
SG3)
1: Yes
0: No
Yes
1
4
ECM JBIG mode (except for
SG3)
SG3)
1: Yes
0: No
Yes
1
5
Inhibited to use
0
6
MH fixed (SG3)
1: Yes
0: None (depending on the
remote machine)
remote machine)
No
0
7
ECM MMR mode (SG3)
1: Yes
0: No
Yes
1
8
ECM JBIG mode (SG3)
1: Yes
0: No
Yes
1
S
W
18
1
Setup of number of times of
call rings
call rings
Binary
input
Bit No.
Setting range
Setting range
1
2
3
4
0 to 9 times
2 times
0
2
0
3
1
4
0
5
Inhibited to use
0
6
0
7
0
8
0
SW
No.
No.
Data
No.
Items
SW selection and functions
Default value
Remarks
Click on the first or last page to see other AR-FX7 service manuals if exist.