Sharp AR-FX7 Service Manual ▷ View online

AR-FX7  SOFT SWITCH  7 - 18
S
W
75
1
Waiting time for CED send 
start
Bit No.
1
2
2.25sec
0
2.25sec
0
0
2
3sec
0
1
0
4sec
1
0
3
CED signal send time
Bit No.
3
4
3sec
0
3sec
0
0
4sec
0
1
4
5sec
1
0
0
6sec
1
1
5
Waiting time for ANSam 
send start
Bit No.
5
6
2.25sec
0
2.25sec
0
0
6
3sec
0
1
0
4sec
1
0
7
ANSam signal send time
Bit No.
7
8
4sec
0
3sec
0
0
4sec
0
1
8
5sec
1
0
1
6sec
1
1
S
W
76
1
Inhibited to use
1
2
0
3
0
4
0
5
1
6
1
7
0
8
1
S
W
77
1
Inhibited to use
0
2
0
3
0
4
0
5
1
6
0
7
1
8
0
S
W
78
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
79
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
80
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7  SOFT SWITCH  7 - 19
S
W
81
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
82
1
CI signal ON time in V.8 
mode
1: 18byte
0: 9bytes
9byte
0
2
CI signal OFF time in V.8 
mode
1: 2sec
0: 1sec
1sec
0
3
Inhibited to use
0
4
CI receive number to shift to 
non-V.34 communication
Bit No.
4
5
2 times
1
Does not shift.
0
0
1 times
0
1
5
2  times
1
0
0
3 times
1
1
6
CI send number to shift to 
Non-V.34 communication
Binary 
input
Bit No.
Setting range
6
7
8
0 to 7 times
When N=0, retrain is not 
made.
2
0
7
1
8
0
S
W
83
1
Inhibited to use
0
2
0
3
1
4
1
5
1
6
1
7
1
8
1
S
W
84
1
Inhibited to use
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
S
W
85
1
Inhibited to use
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
S
W
86
1
Inhibited to use
0
2
CI detection
Bit No.
2
3
4 sine wave
0
When the value is 
outside the setting 
range, the initial value 
is set.
4 sine wave
0
0
3 sine wave
1
0
3
2 sine wave
0
1
0
1
1
4
CI delete max. OFF time
Bit No.
4
5
10sec
0
5sec
0
0
10sec
0
1
5
15sec
1
0
1
20sec
1
1
6
CI signal ON detection 
enable time
Binary 
input
Bit No.
Setting range
6
7
8
0 (155ms) to 7 (225ms)
by increment of 10ms
155ms
0
PWB for Australia 
only can be changed.
7
0
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7  SOFT SWITCH  7 - 20
S
W
87
1
CI signal OFF detectable 
time
Binary 
input
Bit No.
Setting range
1
2
3
4
5
6
7
0 to 1270ms
by increment of 10ms
1200ms
1
2
1
3
1
4
1
5
0
6
0
7
0
8
Inhibited to use
0
S
W
88
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
1
7
1
8
0
S
W
89
1
Inhibited to use
1
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
90
1
Inhibited to use
0
2
1
3
1
4
1
5
1
6
1
7
1
8
1
S
W
91
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
0
7
0
8
0
S
W
92
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
93
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
1
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7  SOFT SWITCH  7 - 21
S
W
94
1
Inhibited to use
0
2
0
3
1
4
0
5
1
6
1
7
0
8
1
S
W
95
1
Inhibited to use
0
2
1
3
0
4
1
5
T1 timer setup
Binary 
input
Bit No.
Setting range
5
6
7
8
15 to 90sec
by increment of 5sec
40sec
0
6
1
7
0
8
1
S
W
96
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
97
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
98
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
99
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
100
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
1
7
0
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks