AR-FX7  SOFT SWITCH  7 - 34
SW39 No. 1 Received document output setting in 
reception
Used to set whether all received documents are outputted at a time
after completion of reception or each document is outputted every time
when it is received.
When set to 1, all are outputted collectively after completion of reception.
When set to 0, output is made after reception of every page.
Default: 1 (Output collectively after completion of reception.)
SW39 No. 2 Specification of data output in case of a 
communication error in reception
Used to set whether the image on the page where a communication
error occurred during image reception is printed or not.
"1": Setup not to print
"0": Setup to print
Default: 0 (Print)
SW39 No. 3 Memory over during reception
Used to set whether the received data are output or destroyed when
memory is over during reception.
When set to 1, the received data are outputted. 
When set to 0, received data are disposed without output.
The default is 1. (The received data are outputted.)
SW39 No. 4 Output method in A3 width reception(AB 
series)
Used to set whether an image of 297mm width is reduced and printed
or an image of 11" width is printed without reduction on paper of 11"
width when an image of A3 width is received. When set to 297mm
width, if a document of 11" is received, both ends are not printed.
When set to 1, printing is made on paper of 297mm width.
When set to 0, printing is made on paper of 11" width.
Default: 1 (Printing is made on paper of 297mm width.)
SW39 No. 5 Output method in A4 width reception (AB series)
Used to set whether printing is made on paper of 8.5" width or of
210mm width when an image of A4 width is received. When set to 8.5"
width, if printed on A4(R), the image is reduced. When set to 210mm
width, if a document of 8.5" is received both ends are not printed.
When set to 1, printing is made on paper of 8.5" width.
When set to 0, printing is made on paper of 210mm width.
Default: 0 (Printing is made on paper of 210mm width.)
SW39 No. 6 Output method in A3 width reception (Inch 
series)
Used to set whether an image of 297mm width is reduced and printed
or an image of 11" width is printed without reduction on paper of 11"
width when an image of A3 width is received. 
When set to 1, printing is made on paper of 297mm width.
When set to 0, printing is made on paper of 11" width.
Default: 0 (Printed on paper of 11" width)
SW39 No. 7 Output method in A4 width reception (Inch 
series)
Used to set whether printing is made on paper of 8.5" width or of
210mm width when an image of A4 width is received.
When set to 1, printing is made on paper of 8.5" width.
When set to 0, printing is made on paper of 210mm width.
Default: 1 (Printed on paper of 8.5" width)
SW39 No. 8 Relay data output
Used to set whether the received document is outputted from the relay
direction station when relay broadcasting direction is received.
When set to 1, the document received from the relay instruction station
is printed.
When set to 0, the document received from the relay instruction station
is not printed.
Default: 1 (Print)
SW40 No. 1 Rotation print
Used to set Enable/Disable of rotation print when the received docu-
ment can be printed by rotation.
When set to 1, the received document is printed by rotation.
When set to 0, the received document is not rotated.
Default: 1 (Printed by rotation)
SW40 No. 2 Override print setup
Used to set whether the latter print job is performed or not when the
former print job is suspended at the first page due to printable paper
empty.
When set to 1, override print is allowed.
When set to 0, override print is not allowed.
Default: 1 (Override print is allowed)
SW40 No. 3 Page number print setup
Used to set whether the page number is added to the position where
date and the sender’s information are printed. (In memory transmis-
sion, page number/total number of pages)
When set to 1, the page number is printed.
When set to 0, the page number is not printed.
Default: 1 (The page number is printed.)
SW40 No. 4 Index print setup
Used to set whether the index is printed on the received document or not.
When set to 1, the index is printed on the received document.
When set to 0, the index is not printed.
Default: 0 (The index is not printed.)
SW40 No. 5 Duplex rotation print
Used to set the duplex rotation print.
Default: 1 (YES)
SW40 No. 6 Reception data duplex print
Used to set YES/NO of the reception data duplex print.
Default: 0 (NO)
SW40 No. 7 Specification of print sequence in duplex print
Used to specify the print sequence in duplex print.
Default: 1 (Print order (214365...))
SW40 No. 8 Specification of rotating direction duplex 
back surface print
Used to specify the rotating direction duplex back surface print.
Default: 1 (180° rotation)
SW41 No. 1 External telephone connection
If this switch is not set to YES, an external telephone cannot be used. 
Default: 1 (YES)
SW41 No.2–No.4 Inhibited to use.
SW41 No.5–No.8 Interval from completion of a 
transmission to the next call-out
Used to set the time interval between the end of a communication and
a call for the next communication.
Setup is made by binary input in the interval of 0 – 15sec.
Default: 6sec
SW42 No.1–No.3 Communication end buzzer sound 
length
Used to specify the length of the communication end sound.
Default: 3.0 sec.
SW42 No.4, No.5 Transmission end sound tone
Used to set the transmission end beep sound tone in transmission.
Default: 0 1 (1000Hz)
SW42 No.6, No.7 Reception end sound tone
Used to set the reception end sound beep tone in reception.
Default: 0 1 (1000Hz)
AR-FX7  SOFT SWITCH  7 - 35
SW42 No. 8 V.34 mode function in manual communication
Used to set Enabled/Disabled V.34 mode function in manual communi-
cation.
When set to 1, V.34 mode function is enabled.
When set to 0, V.34 mode function is disabled.
Default: 1 (V.34 mode function is enabled.)
SW43 No. 1 V.34 mode function
Used to set whether V.34 mode is used for send/receive with the other
party machine is provided with V.34 mode.
When set to 1, send/receive is made with using V.34 mode.
When set to 0, send/receive is made without using V.34 mode.
Default: 1 (Send/receive is made using V.34 mode)
SW43 No. 2 Super G3 disabled in the last call-out of recall 
in case of an error
Used to set Enable/disable of Super G3 in the last call-out of recall in
case of an error.
Default: 0 (Super G3 is void)
SW43 No. 3 V.34 primary channel return mode
Used to set V.34 primary channel return mode.
Default: 1 (PPh)
SW43 No.4–No.6 Symbol speed mask in V.34 reception
Used to set the symbol speed mask in V.34 reception.
Default: 1 0 1 (3429)
SW43 No. 7 V.34 control channel communication speed
Used to set the communication speed of control channel in V.34 mode
transmission.
When set to 1, the communication speed of control channel is
2400bps.
When set to 0, the communication speed of control channel is
1200bps.
Default: 0 (1200bps)
SW43 No. 8 Control channel retrain judgment in V.34 
reception
Used to set the control channel retrain judgment in V.34 reception.
Default: 0 (EQM value judgment)
SW44 No.1–No.4 V.34 primary channel transmission 
speed
Used to set the communication start speed in V.34 mode transmission.
Setup is made in the range of 2400 – 33600bps by binary input of N in
"2400 × N".
N can be set in the range of 0 – 15. Setting to 0 comes  2400bps, 15
comes 33600bps.
Default: N=14 (Transmission starts from 33600bps)
SW44 No.5–No.8 V.34 primary channel reception speed
Used to set the reception start speed in V.34 mode.
Setup is made in the range of 2400 – 33600 bps by binary input of N in
"2400 (bps) × N".
N can be set in the range of 0 – 15. Setting to 0 comes  2400bps, 15
comes 33600bps.
Default: N=14 (Reception starts from 33600bps)
SW45 No.1, No.2 Speaker volume at scanner scan end
Used to set the volume of scan end sound from the speaker when scan
is completed.
Default: 1 0 (Medium)
SW45 No.3–No.8 Pattern number of speaker volume at 
scan end
Pattern of scan end sound volume (Large/Medium/Small)
Default: 21
SW46 No.1, No.2 Speaker volume in DTMF send
Used to set the volume of transmission sound and DTMF sound from
speaker when pressing on-hook button.
Default: 1 0 (Medium)
SW46 No.3–No.8 Pattern number of speaker volume in 
DTMF send
Pattern of volume in DTMF send (Large/Medium/Small)
Default: 21
SW47 No.1, No.2 Volume of line monitor from speaker
Used to set the line sound volume from the speaker in FAX transmis-
sion.
Default: 0 0 (Silent)
SW47 No.3–No.8 Pattern number of line monitor’s volume
Pattern of line monitor volume (Large/Medium/Small)
Default: 21
SW48 No.1, No.2 Volume of communication end sound
Used to set the volume of communication end sound from the speaker
when communication is completed.
Default: 1 0 (Medium)
SW48 No.3–No.8 Pattern number of communication end 
sound
Pattern of communication end sound volume (Large/Medium/Small)
Default: 21
SW49 No.1, No.2 On-hook speaker volume
Used to set the volume from the speaker in on-hook.
Default: 1 0 (Medium)
SW49 No.3–No.8 Pattern number of on-hook speaker 
volume
Used to set the volume pattern (large/medium/small) in on-hook.
Refer to SIM66-37.
Default: 21
SW50 No.1, No.2 Call sound volume
Used to set the ringing sound volume.
Default: 1 0 (Medium)
SW50 No.3–No.8 Pattern number of ringing speaker 
volume
Pattern of call sound volume (Large/Medium/Small)
Default: 21
SW51 No.1, No.2 Busy tone detection cycle
Used to set the number of pulses of busy tone detected to recognize
as busy tone.
When set to 0 0, 2 pulses are detected.
When set to 0 1, 4 pulses are detected.
When set to 1 0, 6 pulses are detected.
When set to 1 1, 10 pulses are detected.
Default: 0 0 (2 pulses are detected)
SW51 No. 3 Busy tone detection time (Upper limit)
Busy tone detection time (Upper limit)
1: 650ms
0: 750ms
Default: 0 (750ms)
SW51 No. 4 Busy tone detection time (Lower limit)
Busy tone detection time (Lower limit)
1: 350ms
0: 250ms
Default: 0 (250ms)
SW51 No. 5 Busy tone detection time (Lower limit 2)
Busy tone detection time lower limit 2
1: 150ms
0: Follows SW51-4.
Default: 0 (Follows SW51-4)
AR-FX7  SOFT SWITCH  7 - 36
SW51 No. 6, No. 7 Inhibited to use.
SW51 No. 8 SDT signal detection
Used to set whether SDT signal which is the second dial tone when
transmitting to F net is detected or not.
When the SDT signal is not detected, dial is made normally even after
“16×.”
When set to 1, the signal is detected.
When set to 0, the signal is not detected.
Default: 0 (Not detected)
SW52 No.1, No.2 DT/BT detection frequency range
Used to set the DT/BT detection frequency range.
Default: 0 1 (420Hz to 680Hz)
SW52 No. 3 Busy tone detection level table
Used to set the busy tone detection level table.
Default: 0 (constant (ROM))
SW52 No.4, No.5 Busy tone detection level
Used to set the lowest detection level when detecting busy tone.
When set to 0 0, busy tone of –43dB is detected.
When set to 0 1, busy tone of –35dB is detected.
When set to 1 0, busy tone of –33dB is detected.
When set to 1 1, busy tone of –30dB is detected.
This setting is made when busy tone is erroneously detected. 
Default: 0 0 (–43dB)
SW52 No.6–No.8 Inhibited to use.
SW53 No.1–No.8 Inhibited to use.
SW54 No.1–No.8 Inhibited to use.
SW55 No.1–No.8 Inhibited to use.
SW56 No.1–No.8 Inhibited to use.
SW57 No.1–No.8 Inhibited to use.
SW58 No.1, No.2 Inhibited to use.
SW58 No.3–No.8 External connection sound volume
Used to set External connection sound volume.
The set range is 0 (0.0dBm) to 48 (–24.0dBm) in the increment of
0.5dBm by binary input.
When set to 49 or greater, the setup value comes as below.
49=–28.0dBm 50=–32.0dBm 51=–36.0dBm 52=–40.0dBm
53=–48.0dBm 54=–56.0dBm 55=–63.0dBm 56 
– 
 infinite (mute)
Default: –10.0dBm
SW59 No.1–No.4 Signal send level Max.
Used to set Signal send level Max.
The set range is 0 (0dBm) to 15 (–15dBm) in the increment of 1dBm by
binary input.
Default: –6dBm
SW59 No.5, No.6 Transmission cable amplitude equalizer
Used to set Transmission cable amplitude equalizer.
Default: 0 0 (0dB)
SW59 No.7, No.8 Reception cable amplitude equalizer
Used to set Reception cable amplitude equalizer.
Default: 0 0 (0dB)
SW60 No.1, No.2 Reception SED ON level
Used to set Reception SED ON level.
Default: 1 1 (–48dB)
SW60 No. 3 Inhibited to use.
SW60 No.4–No.8 Reception gain adjustment
Used to set Reception gain adjustment.
The set range is 0 (+6.0dBm) to 24 (–6.0dBm) in the increment of
0.5dBm by binary input.
Default: 0.0dBm
SW61 No. 1–No.8 Inhibited to use.
SW62 No.1–No.8 Inhibited to use.
SW63 No.1–No.8 Inhibited to use.
SW64 No.1–No.3 Inhibited to use.
SW64 No.4–No.8 DTMF send level (high level)
Used to set the DTMF signal send level (high group).
0 (0.0dBm) to 21 (–21.0dBm) in the increment of 1dBm
Default: –6dBm
SW65 No.1–No.4 Maximum DTMF send level
Used to set the maximum send level in DTMF signal send.
Setup is made in the range of 0 (0.0dBm) to 15 (–15.0dBm) by binary
input.
The setup is made in the increment of 1dB.
Default: 0dBm
SW65 No.5–No.8 DTMF send level (difference between 
high and low level)
Used to set the DTMF signal send level (low group).
0 (–2.0dBm) to 15 (+5.5dBm) in the increment of 0.5dBm
Default: +2.0dBm
SW66 No. 1 Default date, sender print
Used to set whether the registered sender information and date and
time of transmission are printed at the top of the transmission docu-
ment when a document is transmitted through the second line.
When set to 1, date and sender are printed.
When set to 0, date and sender are not printed.
Default: 1 (Date and sender are printed)
SW66 No. 2 Department number notification
Used to set whether the department number is transmitted as sender
information when the department management function is enabled.
Default: 0 (OFF)
SW66 No. 3 Date and sender print position setup
Used to set the print position of date and transmitter information on the
transmitted documents.
When set to 1, added upper inside the document.
When set to 0, added outside the document.
Default: 0 (Added outside the document)
SW66 No. 4, No. 5 Inhibited to use.
SW66 No.6–No.8 Polarity reversion settlement time
Used to set Polarity reversion settlement time.
Setup is made in the range of 200ms – 1600ms by binary input.
Default: 200ms
SW67 No.1–No.4 After sending CFR, double wait is 
inhibited for 1.6sec.
Used to set that the double wait is inhibited for 1.6sec. after sending
CFR.
Setup is made in the range of 0ms – 3000ms by binary input.
Default: 1600ms
SW67 No. 5 Measurement of communication time (image)
Used to set YES/NO of measurement.
Used to measure the communication time in phase C. However, it is
the communication time in the latest phase C. (Unit: msec)
Default: 1 (YES)
AR-FX7  SOFT SWITCH  7 - 37
SW67 No. 6 Reduction transmission mode
Used to set whether the transmitted document is received in reduction
size or both ends of recording paper are cut when the transmitted doc-
ument width is greater than the recording paper width.
When set to 1,  the document is sent without reduction with the both
ends cut.
When set to "0", it is reduced and transmitted.
Default: 0 (Reduction)
SW67 No. 7 ECM
Used to set whether ECM (Error Correction Mode) is performed or not.
When, however, SW43-1 (V.34 mode function) is set to OFF, or when
SW43-1(V.34 mode function is set to ON and the transmission is not
the super G3 transmission, ECM Disable setup is effective. This is
because the ECM function is indispensable in a transmission other
than super G3 transmission in V.34 mode and the other party machine
may perform checking. With SW43-1 (V.34 mode function) is ON and
this reception function is disabled.
When set to 1, ECM is enabled.
When set to "0", ECM is disabled.
Default: 1 (ECM is enabled)
SW67 No. 8 ECM byte/frame
Used to set ECM byte/frame.
Default: 0 (256 [bytes/frame])
SW68 No.1–No.4 Recording paper tray selection (Tray 1 – 
4)
Used to select the tray for output of the received documents.
Tray 1 to Tray 4 can be set to ON/OFF individually. When set to OFF,
the tray does not output received documents.
Setup is made by selecting bit 1 – bit 4. Each bit is selected in the
sequence of tray 1 – tray 4.
When 1 is selected, output is made by using that tray.
When 0 is selected, output is not made by using that tray.
Default: Tray 1 – tray 4 are used. (1)
SW68 No.5–No.8 The tray specification of Duplex print 
(Tray 1 – 4)
Used to select the tray for output of the duplex documents.
Tray 1 to Tray 4 can be set to ON/OFF individually. When set to OFF,
the tray does not output received documents.
Setup is made by selecting bit 5 – bit 8. Each bit is selected in the
sequence of tray 1 – tray 4.
When 1 is selected, output is made by using that tray.
When 0 is selected, output is not made by using that tray.
Default: Tray 1 – tray 4 are used. (1)
SW69 No.1, No.2 Reception size specification (Reception 
capacity)
Used to set the receivable document width which is notified to the
other party when receiving a document.
The setup items are as follows:
Default: 0 0 (Varies depending on the installed cassette.)
Max. allowed reception width selection
Max. allowed reception width is determined by Table 1 and Table
2. This determines the transmitted size from the other party.
When set to A3 with SW69-12,  only with B5 cassette, proxy recep-
tion is always performed. Do not use this combination. (Because
division process in the main scanning direction is not performed.)
When set to A4 with SW69-12, , A3 document from the other party
is not divided into A4 paper but reduction to A4width is requested
to the other party.
• Max. allowed reception width setup
• Max. allowable reception width by installed cassette
SW69 No. 3 11 inch reception capacity setup
When SW69-12,  is set to “Depends on installed cassette,” the max.
allowable reception width by 8.5" × 11" cassette is set.
When set to 1, the reception allowable width is 255mm or 215mm.
When set to 0, the reception allowable width is 303mm or 255mm or
215mm.
Default: 0 (the reception allowable width is 303mm or 255mm or
215mm)
SW69 No. 4 Maximum reception length
Used to set the receivable document width which is notified to the
other party when a long document is sent from the other party.
When set to 1, reception is made without limitations.
When set to 0, if reception of a document reaches 1.5m, reception is
terminated.
Default: 0 (Reception is terminated after receiving 1.5m.)
SW69 No.5, No.6 Image quality in transmission request
Used to set the image capacity of the machine when send request
(polling).
Reflected on DTC.
Default: 0 0 (ultra fine)
SW69 No. 7 Countermeasures for echo in reception (CED 
tone send interval)
Used to select ON/OFF of countermeasures against echo.
An interval of 500ms is inserted before DIS transmission.
Default: 0 (75ms)
SW69 No. 8 Countermeasure for echo in transmission 
(After reception of DIS, hold time up to signal send is set.)
Used to select ON/OFF of countermeasures against echo.
An interval of 500ms is inserted before DCS transmission.
Default: 0 (200ms)
bit
1
: Tray 1
bit
2
: Tray 2
bit
3
: Tray 3
bit
4
: Tray 4
bit
5
: Tray 1
bit
6
: Tray 2
bit
7
: Tray 3
bit
8
: Tray 4
bit
1
2
0
0
: By the equipped cassette
0
1
: B4 (A4, B4)
1
0
: A4
1
1
: A3 (A4, B4, A3)
SW69
Size specification
Allowable reception 
width
No.1
No.2
0
0
Depends on the 
installed cassette.
Varies according to the 
table below.
0
1
B4
A4 & B4 width
1
0
A4
A4 width
1
1
A3
A4 & B4 & A3 width
[Max. paper size of installed 
cassette with FAX function]
[Sampled paper size (data 
width)]
A5
A4
B5
B4
A4
A3
B4
B4
A3
A3
No cassette with FAX function
A3