AR-FX7  SOFT SWITCH  7 - 38
SW70 No. 1 CED signal send
Used to set whether CED signal is sent or not. This setup is effective
only when SW43-1 (V.34 mode function) is off. This is because V.34
mode requires sending of ANSam signal.
When set to 1, CED (ANSam) signal is sent.
When set to 0, CED (ANSam) signal is not sent.
Default: 1 (CED (ANSam) signal is sent)
SW70 No. 2 CSI transmission
CSI signal includes the telephone number registered as sender’s num-
ber. Used to set whether this signal is sent or not.
When set to 1, CSI signal is sent.
When set to 0, CSI signal is not sent.
Default: 1 (CSI signal is sent)
SW70 No. 3 DIS reception check in G3 send
Used to set whether DIS reception is checked or not in a send mode
other than SG3 send.
When set to 1, DIS reception is always checked twice.
When set to 0, DIS reception is checked once.
Default: 0 (1 time)
SW70 No.4, No.5 DIS process selection in reception
Used to set the process when DIS is received.
When set to 0 0, it is judged as reception of echo and the command is
sent again.
When set to 0 1, the line is disconnected as improper DIS.
When set to 1 0, when DIS judges that the receiver has poled docu-
ments, poled transmission and the other are judged as reception of an
echo and the command is sent again.
When set to 1 1, when DIS judges that the receiver has poled docu-
ments, poled transmission is made. When DIS judges that the trans-
mitter received an echo, the command is sent again. In the other case,
it is judged as improper DIS and the line is disconnected.
Default: 0 0 (Judged as reception of echo, and the command is sent
again.)
SW70 No. 6 DIS 41Bit or later enable/disable
Used to set Enable/Disable of DIS 41Bit or later
Default: 0 (Enabled)
SW70 No. 7 Time between DCS and TCF
Used to set the time between DCS and TCF.
Default: 1 (75ms)
SW70 No. 8 TCF check time
Used to set TCF check time
Default: 1 (1.0sec)
SW71 No.1–No.3 Inhibited to use.
SW71 No. 4 Telephone line menu
Used to set whether Tone/Pulse setup is displayed on the menu or not.
Default: 1 (Inhibited)
SW71 No. 5–No.8 Inhibited to use.
SW72 No.1, No.2 RCP send times
Used to set RCP send times.
Default: 0 0 (3 times)
SW72 No.3–No.6 The number of the flag detection bytes
Used to set the number of the flag detection bytes.
Setup is made in the range of 0 – 15 by binary input.
Default: 4
SW72 No. 7 EYE-Q check
Used to set whether TCF is checked or not in TCF reception.
When set to 1, check is made only with EYE-Q value. Therefore, TCF
check becomes loose.
When set to 0, check is made both with received data and EYE-Q
value.
Default: 0 (check is made both with received data and EYE-Q value. )
SW72 No. 8 Operation when error frame is received.
Used to set the operation when image data with error frame is
received.
"1": Continues process.
"0": Process is not continued. (Judged as an error.)
Default: 0 (Process is not continued. (Judged as an error.))
SW73 No. 1 Error process in RTN reception
Used to set whether RTN reception is treated as a communication
error or not.
When set to 1, it is not judged as an error when RTN is received.
When set to 0, it is judged as an error when RTN is received.
Default: 0 (it is judged as an error)
SW73 No.2, No.3 RTN send line error rate
Used to set RTN send line error rate.
Default: 1 0 (60 lines)
SW73 No.4, No.5 Flag-address timer setup (V.21-FSK)
Used to set the time between Flag-adrs during FSk signal reception in
a communication other than V.34 mode.
FSK signal reception in V.34 does not conform to this soft switch.
Default: 0 0 (6 sec)
SW73 No. 6 Reception waiting time between frames
Used to set Reception waiting time between frames.
Default: 0 (3.4sec)
SW73 No.7, No.8 Minimum flags between frames
Used to set Minimum flags between frames.
Default: 0 0 (2-flag)
SW74 No.1–No.4 FSK signal settlement time in double 
wait
Used to set FSK signal settlement time in double wait.
Setup is made in the range of 200 – 950ms by binary input of N in "X
(ms) = 50 (ms) × N + 200".
N can be set in the range of 0 – 15.
Default: 400ms
SW74 No.5, No.6 Preamble send time of 300bps
Used to set the preamble send time of 300bps.
Default: 0 1 (1.0 sec)
SW74 No.7, No.8 Phase C head dummy data send time
Used to set Phase C head dummy data send time.
Default: 0 0 (0.2 sec)
SW75 No.1, No.2 Waiting time for CED send start
Used to set the waiting time for CED send start.
Default: 0 0 (2.25 sec)
SW75 No.3, No.4 CED signal send time
Used to set CED signal send time.
Default: 0 0 (3 sec)
SW75 No.5, No.6 Waiting time for ANSam send start
Used to set the waiting time for ANSam send start.
Default: 0 0 (2.25 sec)
SW75 No.7, No.8 ANSam signal send time
Used to set ANSam signal send time.
Default: 0 1 (4 sec)
AR-FX7  SOFT SWITCH  7 - 39
SW76 No. 1–No. 8 Inhibited to use.
SW77 No. 1–No. 8 Inhibited to use.
SW78 No. 1–No. 8 Inhibited to use.
SW79 No. 1–No. 8 Inhibited to use.
SW80 No. 1–No. 8 Inhibited to use.
SW81 No. 1–No. 8 Inhibited to use.
SW82 No. 1 CI signal ON time in V.8 mode
Used to set the CI signal ON time in V.8 mode.
Default: 0 (9 bytes)
SW82 No. 2 CI signal OFF time in V.8 mode
Used to set the CI signal OFf time in V.8 mode.
Default: 0 (1sec)
SW82 No. 3 Inhibited to use.
SW82 No.4, No.5 CI receive number to shift to non-V.34 
communication
Used to set CI receive number to shift to non-V.34 communication.
Default: 1 0 (2 times)
SW82 No.6–No.8 CI send number to shift to Non-V.34 
communication
Used to set CI send number to shift to non-V.34 communication.
Setup is made in the range of 0 – 7 by binary input.
When set to 0, retrain is not made.
Default: 2
SW83 No.1–No.8 Inhibited to use.
SW84 No.1–No.8 Inhibited to use.
SW85 No.1–No.8 Inhibited to use.
SW86 No.1 Inhibited to use.
SW86 No.2, No.3 CI detection
Used to set the frequency to detect CI signal which is the calling signal
as follows:
Default: 0 0 (4 sine wave)
SW86 No.4, No.5 CI delete max. OFF time
Used to set the max. wait time from detection of CI signal pulse (num-
ber of times) to the next CI signal pulse detection. If next CI signal
pulse is not detected within this time, the number of calls up to now is
cleared.
The setup items are as follows:
Default: 0 1 (10 sec)
SW86 No.6–No.8 CI signal ON detection enable time
Used to set the time to judge that CI signal is ON.
The CI signal of less than this setup time is not regarded as ON.
The set range is 0 (155ms) – 7 (225ms) in the increment of 10ms.
Default: 155ms
SW87 No.1–No.7 CI signal OFF detectable time
Used to set the min. OFF time for judgment of CI pulse (16Hz call sig-
nal). When OFF time continues for more than the set time, it is judged
as 1 pulse of CI.
The set range is 0 to 1270 by binary input of "N × 10ms".
Default: 1200ms
SW87 No. 8 Inhibited to use.
SW88 No.1–No.8 Inhibited to use.
SW89 No. 1–No.8 Inhibited to use.
SW90 No. 1–No.8 Inhibited to use.
SW91 No. 1–No.8 Inhibited to use.
SW92 No.1–No.8 Inhibited to use.
SW93 No.1–No.8 Inhibited to use.
SW94 No.1–No.8 Inhibited to use.
SW95 No.1–No.4 Inhibited to use.
SW95 No.5–No.8 T1 timer setup
Used to set time-out time from phase B to detection of signal.
T1 time-out time is set in the range of 15 – 90sec (in the increment of
5sec).
Default: 40sec
SW96 No.1, No.8 Inhibited to use.
SW97 No.1–No.8 Inhibited to use.
SW98 No.1–No.8 Inhibited to use.
SW99 No.1–No.8 Inhibited to use.
SW100 No.1–No.8 Inhibited to use.
SW101 No.1–No.8 Inhibited to use.
SW102 No.1–No.8 Inhibited to use.
SW103 No.1–No.8 Inhibited to use.
SW104 No.1–No.8 Inhibited to use.
SW105 No.1–No.8 Inhibited to use.
SW106 No.1–No.8 Inhibited to use.
SW107 No.1–No.8 Inhibited to use.
SW108 No.1–No.8 Inhibited to use.
SW109 No.1–No.4 Print lead edge adjustment (Left edge 
adjustment)
Setup of print image area void
The quantity of void at the left edge in main scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW109 No.5–No.8 Print lead edge adjustment (Lead edge 
adjustment)
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
bit
2
3
0
0
: 4 sine wave
1
0
: 3 sine wave
0
1
: 2 sine wave
bit
4
5
0
0
: 5sec
0
1
: 10sec
1
0
: 15sec
1
1
: 20sec
AR-FX7  SOFT SWITCH  7 - 40
SW110 No.1–No.4 Print lead edge adjustment (Rear edge 
adjustment)
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW110 No.5–No.8 Print lead edge adjustment (left edge 
position) rear
Setup of print image area void
The quantity of void at the left edge in main scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW111 No.1–No.4 Print lead edge adjustment (lead edge 
position) rear
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 lines in the interval of 16 lines
Default: 48 lines
SW111 No.5–No.8 Print lead edge adjustment (rear edge 
position) rear
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 lines in the interval of 16 lines
Default: 48 lines
SW112 No.1–No.8 Print magnification ratio adjustment 
(horizontal)
Used to adjust the print magnification radio in main scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW113 No.1–No.8 Print magnification radio adjustment 
(vertical)
Used to adjust the print magnification radio in sub scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW114 No.1–No.4 Scan effective image area (OC) vertical 
lead edge image loss
Used to set the image loss in OC scan image area.
The quantity of image loss at the lead edge in sub scan direction can
be adjusted. When the set value is increased, the lead edge image
loss quantity is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW114 No.5–No.8 Vertical rear edge image loss in scan 
effective image area (OC)
Used to set the image loss in OC scan image area.
The quantity of image loss at the rear edge in sub scan direction can
be adjusted. When the set value is increased, the image loss quantity
at the rear edge is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW115 No.1–No.4 Scan effective image area (OC) 
horizontal left edge image loss
Used to set the left edge image loss of main scan in OC scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW115 No.5–No.8 Scan effective image area (OC) 
horizontal right edge image loss
Used to set the right edge image loss of main scan in OC scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW116 No.1–No.8 Scan magnification adjustment OC 
(horizontal)
Used to adjust the OC scan magnification ratio in main scan direction.
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW117 No.1–No.8 Scan magnification ratio adjustment 
OC (vertical)
Used to adjust the OC scan magnification ratio in sub scan direction.
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW118 No.1–No.4 Scan effective image area (SPF) vertical 
lead edge image loss
Used to set the image loss in SPF scan image area.
The quantity of image loss at the lead edge in sub scan direction can
be adjusted. When the set value is increased, the lead edge image
loss quantity is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 81 lines
Default: 0 lines
SW118 No.5–No.8 Vertical rear edge image loss in scan 
effective image area (SPF)
Used to set the image loss in SPF scan image area.
The quantity of image loss at the rear edge in sub scan direction can
be adjusted. When the set value is increased, the image loss quantity
at the rear edge is increased.
Setup of SIM 50-8 is reflected.
0 to ±14 lines in the interval of 21 lines
Default: +0 lines
SW119 No.1–No.4 Scan effective image area (SPF) 
horizontal left edge image loss
Used to set the left edge image loss of main scan in SPF scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
AR-FX7  SOFT SWITCH  7 - 41
SW119 No.5–No.8 Scan effective image area (SPF) 
horizontal right edge image loss
Used to set the right edge image loss of main scan in SPF scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW120 No.1–No.4 Scan effective image area (SPF) rear 
vertical lead edge image loss
Used to set the image loss in SPF scan image area.
The quantity of image loss at the lead edge in sub scan direction can
be adjusted. When the set value is increased, the lead edge image
loss quantity is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW120 No.5–No.8 Scan effective image area (SPF) rear 
vertical rear edge image loss
Used to set the image loss in SPF scan image area.
The quantity of image loss at the rear edge in sub scan direction can
be adjusted. When the set value is increased, the image loss quantity
at the rear edge is increased.
Setup of SIM 50-8 is reflected.
0 to ±14 lines in the interval of 2 lines
Default: +0 lines
SW121 No.1–No.4 Scan effective image area (SPF) rear 
horizontal left edge image loss
Used to set the left edge image loss of main scan in SPF scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW121 No.5–No.8 Scan effective image area (SPF) rear 
horizontal right edge image loss
Used to set the right edge image loss of main scan in SPF scan of
FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW122 No.1–No.8 Scan magnification ratio adjustment 
SPF (horizontal)
SPF main scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW123 No.1–No.8 Scan magnification ratio adjustment 
SPF (vertical)
SPF sub scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW124 No.1–No.8 Print magnification ratio adjustment 
rear (horizontal)
Used to adjust the print magnification radio in main scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW125 No.1–No.8 Print magnification ratio adjustment 
rear (vertical)
Used to adjust the print magnification radio in sub scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW126 No.1–No.8 Scan magnification ratio adjustment 
SPF rear (horizontal)
SPF main scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW127 No.1–No.8 Scan magnification ratio adjustment 
SPF rear (vertical)
SPF sub scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW128 No.1–No.8 Inhibited to use.
SW129 No.1–No.8 Inhibited to use.
SW130 No.1–No.8 Inhibited to use.
SW131 No.1–No.8 Inhibited to use.
SW132 No.1–No.8 Inhibited to use.
SW133 No.1–No.8 Inhibited to use.
Page of 104