DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE

Model
AR-FX7
Pages
104
Size
4.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARFX7-Service Manual
File
ar-fx7.pdf
Date

Sharp AR-FX7 Service Manual ▷ View online

AR-FX7  SOFT SWITCH  7 - 30
SW17 No. 3 ECM MMR mode (except for SG3)
Used to set whether MMR encoding system is allowed or inhibited,
except for SG3 communication.
When set to 1, MMR encoding system is allowed.
When set to 0, MMR encoding system is inhibited.
Default: 1 (MMR encoding system is allowed)
SW17 No. 4 ECM JBIG mode (except for SG3)
Used to set whether JBIG encoding system is allowed or inhibited,
except for SG3 communication.
When set to 1, JBIG encoding system is allowed.
When set to 0, JBIG encoding system is inhibited.
Default: 1 (JBIG encoding system is allowed)
SW17 No. 5 Inhibited to use.
SW17 No. 6 MH fixed (SG3)
Used to set whether the encoding system is fixed to MH or not in SG3
communication.
When set to 1, the encoding system is fixed to MH.
When set to 0, the encoding system is not fixed to MH.
Default: 0 (The encoding system is not fixed to MH.)
SW17 No. 7 ECM MMR mode (SG3)
Used to set whether MMR encoding system is allowed or not in SG3
communication.
When set to 1, MMR encoding system is allowed.
When set to 0, MMR encoding system is inhibited.
Default: 1 (MMR encoding system is allowed)
SW17 No. 8 ECM JBIG mode (SG3)
Used to set whether JBIG encoding system is allowed or not in SG3
communication.
When set to 1, JBIG encoding system is allowed.
When set to 0, JBIG encoding system is inhibited.
Default: 1 (JBIG encoding system is allowed)
SW18 No.1–No.4 Setup of number of times of call rings
Used to set the number of call rings until reception is started in auto
reception mode.
Setup is in the range of 0 – 9 (times) by binary input.
When set to 0, no ring is made.
Default: 2 times
SW18 No.5–No.8 Inhibited to use.
SW19 No.1–No.4 Minimum pause time (10PPS) setup
Used to set the minimum pause time (10PPS).
Setup is made in the range of 0 (525ms) – 15 (900ms) by binary input
of N in "X (ms) = (N × 25) + 525".
Default: 825ms
SW19 No. 5–No.8 Inhibited to use.
SW20 No. 1 Inhibited to use.
SW20 No. 2–No.4 PBX setup (Inhibited except for 
Germany and France.)
Used to select send signal of register recall.
In concrete, ID (pulse signal up to 3 digits) and Flash (1-pulse signal)
are selected.
Default: 0 0 0 (Setup OFF)
SW20 No. 5 SIM DTMF sound speaker selection window
Used to set YES/NO of SIM DTMF sound speaker selection screen.
Default: 0 (NO)
SW20 No.6, No.7 Flash send wait time
Used to set wait time from off-hook status to Flash signal transmission
in the register recall function.
Default: 0 0 (0sec) (U.K, France)
1 0 (1sec) (Germany)
 (Fixed to 0 except for Germany.)
SW20 No. 8 Receivable memory capacity
Used to set the remaining memory capacity for acceptance of call.
When set to 1, ringing is made until the remaining memory capacity is
64KB or less.
When set to 0, ringing is made until the remaining memory capacity is
128KB or less.
Default: 0 (Ringing is made until the remaining  is 128KB or less.)
SW21 No. 1 Dial tone detection
Used to set whether dial tone detection is performed or not in auto dial
ringing.
"1": Yes
"0": No
When set to YES and dial tone is not detected, dial is not performed.
Default: 0 (NO)
SW21 No. 2 Busy tone detection
Used to set whether busy tone signal is detected or not in ringing.
When set to 1, busy tone is detected.
When set to 0, busy tone is not detected.
Default: 1 (Busy tone is detected.)
SW21 No. 3 Dial tone monitoring time
Used to set dial tone monitoring time when detecting dial tone.
"1": 10sec
"0": 5sec
Default: 0 (5sec)
SW21 No. 4 CED detection time
Used to set CED/ANSam signal detection time. When the CED/
ANSam signal is detected for duration of the set time, it is recognized.
When set to 1, if a signal is detected for 500ms or more, it is recog-
nized.
When set to 0, if a signal is detected for 1000ms or more, it is recog-
nized.
Default: 0 (1000ms or more)
SW21 No.5–No.8 Inhibited to use.
SW22 No.1, No.2 Waiting time for dial start
Used to set wait time from connection of the line to start of dial ringing.
When ringing is made without detecting dial tone, ringing is made after
setting this time. 
When set to 0 0, ringing is made after 3.5sec.
When set to 0 1, ringing is made after 4sec.
When set to 1 0, ringing is made after 5sec.
When set to 1 1, ringing is made after 6sec.
Default: 3.5sec.
SW22 No.3, No.4 CNG send start time
Used to set the CNG send start time.
Default: 0 0 (0.5 sec)
SW22 No.5, No.6 Tone/pulse default setup
Use line setting (Dial setting)
Selection of 10PPS, 20PPS, and TONE is available. 
The setup items are as follows:
Default: 1 0 (Tone)
SW22 No. 7 DPMUTE control
Used to set whether DPMUTE control is used or not.
1: ON
0: OFF
Default: 0 (OFF)
bit
5
6
0
0
: 10PPS
0
1
: 20PPS
1
0
: TONE
AR-FX7  SOFT SWITCH  7 - 31
SW22 No. 8 DP dial pulse number process
Used to set the process of the number of DP dialing pulse.
1: 10-N
0: Normal (N)
Default: 0 (Normal N)
SW23 No.1 Inhibited to use.
SW23 No. 2 Monitoring polarity reversion during send 
image
Used to set YES/NO of monitoring polarity reversion during communi-
cation on the dialing side.
When set to 1, polarity reversion is monitored.
When set to 0, polarity reversion is not monitored.
Default: 0 (NO) (fixed)
SW23 No. 3 Monitoring polarity reversion during 
communication
Used to set whether the poolarity reversion is monitored or not during
dialing.
When set to 1, polarity reversion is monitored.
When set to 0, polarity reversion is not monitored.
Default: 0 (NO) (fixed)
SW23 No.4–No.8 Setting of time before dial (10PPS) 
Used to set the time before dial (10PPS) 
Setup is made in the range of 0 (50ms) – 31 (360ms) by binary input of
N in "X (ms) = (N × 10) + 50".
Default: 300ms
SW24 No.1–No.4 Inhibited to use.
SW24 No.5–No.8 Waiting time for OFF HOOK
Used to set the wait time of OFF HOOK.
The set range is 0 (50ms) – 15 (200ms) in the increment of 10ms by
binary input of N in “X (ms) = (N x 10) + 50”.
Default: 100ms
SW25 No.1–No.4 Make time (10PPS) setup
Used to set the make rate when dialing at 10PPS.
The set range of N is 0 to 15 in binary input for the make rate of (N +26
ms), which ranges from 26 to 41 ms.
Default: 34ms (U.K., France)
41ms (Germany)
SW25 No.5–No.8 Inhibited to use.
SW26 No.1–No.5 DTMF signal send time
Used to set the send time when sending DTMF signal.
Setup is made in the range of 60 – 310ms by binary input of N in
"10(ms) × N" in the increment of 10ms.
N can be set in the range of 6 – 31.
When N is set to 0, it is the same as 110ms (N=11).
Default: 110ms
SW26 No.6–No.8 Minimum pause time (DTMF) setup
Used to set the minimum pause time (DTMF).
Setup is made in the range of 90 – 160ms by binary input of N in "X
(ms) = (N × 10) + 90" in the increment of 10ms.
N can be set in the range of 0 – 7.
Default: 120ms
SW27 No. 1 Inhibited to use.
SW27 No.2–No.4 Setting of time before dial (DTMF) 
Used to set the time before dial (DTMF) 
Setup is made in the range of 30 – 100ms by binary input of N in "X
(ms) = (N × 10) + 30" in the increment of 10ms.
N can be set in the range of 0 – 7.
Default: 50ms
SW27 No.5–No.8 Setting of DPMUTE OFF time after dial
Used to set DPMUTE OFF time after dial.
Setup is made in the range of 5 – 80ms by binary input of N in "X (ms)
= (N × 5) + 5" in the increment of 5ms.
N can be set in the range of 0 – 15.
Default: 50ms
SW28 No.1–No.4 Pause time setup
Used to set the pause time.
The set range is 1 sec to 15 sec by binary input.
When set to 0 sec, the same as the setup of 2 sec.
Default: 2sec
SW28 No.5, No.6 Flash send time
Used to set ON time of Flash pulse width to be sent in sending Flash
signal to the line.
Default: 0 0 (90ms) (Fixed to 0 except for Germany and France.)
SW28 No.7, No.8 Line open delay time in dial test
Used to set the line open delay time in dial test.
Default: 0 0 (2 sec)
SW29 No. 1 Communication record table automatic print
Used to set whether the communication record table is printed auto-
matically when each of transmission/reception data of communication
record table reaches 50 items.
When set to 1, the table is automatically printed.
When set to 0, the table is not printed though the data reaches 50
items.
Default: 0 (No print)
SW29 No. 2 Time specification of communication record 
table
Used to set whether time is enabled or not in the output function of
communication record table at the specified time.
Linked with the key operator program.
Default: 0 (Inhibited)
SW29 No.3, No.4 Sequence of year, month, and day on the 
LCD, the report, and the sender’s record
Used to set the recording sequence of year, month, and day on the
LCD, reports, and the sender’s record.
Default: Day, month, year
SW29 No.5–No.8 Call time setup in automatic 
transmission (T0 timer setup)
Used to set the call time when call does not reach the other party in
auto send mode.
The set range is 30 to 75 sec in the increment of 5 sec by binary input
of "(5 sec × N) + 30 sec)".
N can be set in the range of 0 – 15. Setting to 10 – 15 (setup of 80 –
105 sec) comes the same as the setup of 45 sec.
Default: 45sec (N=3)
SW30 No.1–No.3 Inhibited to use.
SW30 No.4–No.8 Time specification print  (o’clock) on the 
communication report table
Used to set "o’clock" of the time (o’clock, min) when specifying the time
on the communication report table.
Setup is in the range of 0 – 23 (o’clock) by binary input.
When set to 24 – 31, the time is set to 0 o’clock.
Default: 0 o’clock
SW31 No.1, No.2 Inhibited to use.
AR-FX7  SOFT SWITCH  7 - 32
SW31 No.3–No.8 Time specification print  (min) on the 
communication report table
Used to set "min" of the time (o’clock, min) when specifying the time on
the communication report table.
Setup is in the range of 0 – 59 (min) by binary input.
(When set to 60 – 63, the time is set to 0min.)
Default: 0 min
SW32 No.1, No.2 Default telephone book setup
Used to set YES/NO of default telephone book displaying.
Default: 0 0 (Basic screen)
SW32 No. 3 Next address key input in broadcast
Used to set YES/NO of Next address key input in broadcast.
Default: 0 (No)
SW32 No.4, No.5 One-touch dial display number switch
Used to set the number of one-touch dial display.
Default: 0 1 (8)
SW32 No. 6 Shift of the power OFF state in shut off
Used to set whether the shift of the power OFF state in shut off is
allowed or inhibited.
Default: 1 (allowed)
SW32 No. 7 Time indication format
Used to set the sequence of year, month, and day in the LCD display,
report, and sender record.
When set to 1, time is indicated in AM/PM format.
When set to 0, time is indicated in 24H format.
Default: 0 (24H)
SW32 No. 8 Priority in the day of week
Used to set the recording sequence of the day of month and the day of
week if the date is in the sequence of month, day, and year.
Default: 0 (No) (U.K.)
1 (Yes) (Germany, France)
SW33 No. 1 Inhibited to use.
SW33 No. 2 Report output on less than A4 (LTR)
Used to set the report output on less than A4 (LTR).
Default: 0 (Reduction by the record volume)
SW33 No. 3 Own FAX No. mark of TX image
Used to set own number’s mark in TX image header. (English only)
When set to 1, mark is TEL icon (
).
When set to 0, mark is “FAX:”.
Default: 0 (FAX:)
SW33 No.4, No.5 Contents of send document are printed 
in memory send
Used to set Print/Not print part of the sent document in the transmis-
sion result table in case of a memory transmission error.
When set to 0 0, the transmitted document is not printed on the trans-
mission result table.
When set to 0 1, all the transmitted document are printed on the trans-
mission result table.
When set to 1 0, the transmitted document is printed on the transmis-
sion result table only when the transmission is failed.
Default: 1 0 (when the transmission is failed)
SW33 No. 6 Transmission document content print in F 
code transmission
Used to set whether the sent document content is print or not in F code
transmission.
SW33-4 – 5 must be set to output.
Default: 1 (Not print)
SW33 No. 7 Function to attach images to the report table 
of memory confidential send
Used to set whether images are attached to the report table of memory
confidential send
Default: 0 (NO)
SW33 No. 8 Total communication time and total number of 
pages print on communication record table
Used to set Print/Not print  the total communication time and the total
number of pages on the communication record table.
When set to 1, the total communication time and the total number of
pages are printed on the communication record table.
When set to 0, not printed on the communication record table.
Default: 1 (YES)
SW34 No.1, No.2 Report output (in reception)
Used to set whether the communication report table is outputted or not
when a reception (excluding confidential reception) is made.
Setup is selected from "print inhibition," "all output," and "only when
transmission is failed" as follows:
Default: 0 0 (printing is inhibited)
SW34 No.3, No.4 Report output (in transmission)
Used to set whether the communication report table is outputted or not
after the transmission (excluding broadcast, sequential send request,
and relay broadcast).
Setup is selected from "print inhibition," "all output," and "only when
transmission is failed" as follows:
Default: 1 0 (Only when transmission is failed)
SW34 No. 5 Communication report output (in confidential 
reception)
Used to set whether the communication report table is outputted or not
when a confidential reception is made.
When set to 1, the communication report table is printed.
When set to 0, the communication report table is not printed.
Default: 1 (Print)
SW34 No.6, No.7 Report output (In broadcast, sequential 
send request, and relay broadcast)
Used to set whether the communication report table is outputted or not
after the transmission (in broadcast, sequential send request, and
relay broadcast).
Setup is selected from "print inhibition," "all output," and "only the
address to which transmission is failed" as follows:
Default: 0 1 (All print)
SW34 No. 8 Report output when canceling
Used to set whether the communication report table is outputted or not
when canceling transmission during document transmission.
When set to 1, the communication report table is printed.
When set to 0, the communication report table is not printed.
Default: 0 (No print)
bit
1
2
0
0
: Print is inhibited.
0
1
: Print all
1
0
: Only in case of an error
bit
3
4
0
0
: Print is inhibited.
0
1
: Print all
1
0
: Only when transmission is failed
bit
6
7
0
0
: Print is inhibited.
0
1
: Print all
1
0
: Only the address to which transmission is failed
AR-FX7  SOFT SWITCH  7 - 33
SW35 No. 1 Automatic reduction print
Used to set whether the received document is automatically reduced
and printed so that the print-out is fit in a fixed size when the document
size is longer than the fixed sizes but smaller than the max. length of
automatic reduction ratio.
When set to 1, the document is printed with automatic reduction.
When set to 0, the document is printed without reduction.
Default: 1 (Automatic reduction print enable)
SW35 No. 2 Paper selection priority
Used to set whether the FAX reception paper is selected by data width
priority or data area priority.
"1": Width priority
"0": Area priority
Default: 0 (area priority)
SW35 No.3, No.4 Output condition setup
Used to set whether the received data are reduced or divided to print
when a document is received and there is no suitable size paper.
Default: 0 0 (Reduction print)
SW35 No.5–No.8 Automatic reduction rate setup
Used to set the length of a received document which can be automati-
cally reduced and printed on paper longer than the fixed sizes when
automatic reduction print is allowed.  
Setup is made in the range of 0 – 15% by binary input of N in "100% –
N × 1%."
Default: 94% (6% reduction)
SW36 No.1–No.4 Waiting time for PC-FAX job end
Used to set the waiting time for PC-FAX job end.
The set range is 0 (32 min) to 15 (2 min) in the increment of 2 min by
binary input.
Default: 2 min.
SW36 No.5, No.6 Inhibited to use.
SW36 No.7, No.8 Waiting time for lift-up
Used to set the wait time before starting printing when the cassette is
being lift up in print ready state.
Default: 0 0 (30 sec)
SW37 No. 1 Thin paper setup
Used to set whether the thin paper use is allowed or not.
Default: 0 (Inhibited)
SW37 No. 2 Specification of 1m scan when there is no line 
send setting 
Used to set “Reception specification of 1m” when SW37-3 – 6 (Rota-
tion transmission selection) is set to NO.
Default: 0 (Normal operation)
SW37 No. 3 Rotation send selection (A4 
 A4R)
Used to set whether A4 document is transmitted as A4 or the scanned
image is rotated and transmitted as A4R.
When set to 1, the document is transmitted as A4 width.
When set to 0, the document is transmitted as A3 width.
Default: 1 (Transmitted as A4 width)
SW37 No. 4 Rotation transmission selection (B5R 
 B5)
Used to set whether B5R document is transmitted as B5R or the
scanned image is rotated and transmitted as B5.
When set to 1, the document is transmitted as B4 width (B5).
When set to 0, the document is transmitted as A4 width (B5R).
Default: 1 (Transmitted as B4 width)
SW37 No. 5 Rotation transmission selection (A5R 
 A5)
Used to set whether A5R document is transmitted as A5R or the
scanned image is rotated and transmitted as A5.
When set to 1, the document is transmitted as A4 width (A5).
When set 0, the document is transmitted as A4 width (A5R).
(However, the transmission width is A4.)
Default: 1 (Transmitted as A4 width (A5))
SW37 No. 6 Rotation transmission selection (11 × 8.5 
 
8.5 × 11)
Used to set whether Letter (landscape) document is transmitted as A3
width or the scanned image is rotated and transmitted as A4R width.
Default: 1 (Rotation)
SW37 No. 7 Inhibited to use.
SW37 No. 8 Rotation scan word calculation
Used to set the rootation scan word calculation.
Default: 0 (Round down)
SW38 No. 1 Protocol monitor
Used to set whether communication protocol result is printed after
completion of communication or not.
Used for communication test.
Default: 0 (No print)
SW38 No. 2 Output only in case of an error of the protocol 
monitor
Used to set whether protocol monitor is outputted only when a commu-
nication error occurs or every time when communication is completed.
Effective when SW38-1 (Protocol monitor) is set to YES. However,
only when SW38-1 is set to 1 (YES), protocol monitor is outputted in
case of a communication error.
Default: 0 (NO)
SW38 No. 3 Protocol monitor save
Used to set whether the protocol monitor of the final communication is
saved or not.
When set to "Saved," the preceding protocol monitor can be printed
with SIM 66-21.
Default: 1 (Save)
SW38 No.4, No.5 Line sound monitor range
Used to set the line sound monitor range when the line monitor func-
tion is used.
Used to set to monitor NSF signal send/receive until NSF signal is
sent/received.
When set to ALL, all procedures up to line disconnection are moni-
tored.
The setup items are as follows:
Default: 0 1 (Up to NSF signal send/receive)
SW38 No. 6 Line monitor display
Used to set whether the communication speed and the reception level
are displayed on the LCD or not.
Displayed on the communication status screen by pressing the job sta-
tus key.
When set to 1, displayed on LCD.
When set to 0, not displayed on LCD.
Default: 0 (not displayed)
SW38 No. 7–No. 8 Inhibited to use.
bit
3
4
0
0
: Reduction allowed
0
1
: AB
1
0
: Division allowed
1
1
: A
bit
4
5
0
0
: OFF
0
1
: Until NSF signal is sent/received
1
0
: All
1
1
Page of 104
Display

Click on the first or last page to see other AR-FX7 service manuals if exist.