DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE

Model
AR-FX7
Pages
104
Size
4.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARFX7-Service Manual
File
ar-fx7.pdf
Date

Sharp AR-FX7 Service Manual ▷ View online

AR-FX7  SOFT SWITCH  7 - 26
S
W
126
1
Scan magnification ratio 
adjustment SPF rear 
(horizontal)
1: –
0: +
+
0
2
Binary 
input
Bit No.
Setting range
2
3
4
5
6
7
8
0  to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
127
1
Scan magnification ratio 
adjustment SPF rear 
(vertical)
1: –
0: +
+
0
2
Binary 
input
Bit No.
Setting range
2
3
4
5
6
7
8
0  to ± 12.7%
by increment of 0.1%
0%
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
128
1
Inhibited to use
0
2
0
3
0
4
1
5
1
6
0
7
1
8
0
S
W
129
1
Inhibited to use
0
2
0
3
1
4
0
5
0
6
0
7
1
8
0
S
W
130
1
Inhibited to use
0
2
0
3
1
4
0
5
1
6
0
7
1
8
0
S
W
131
1
Inhibited to use
0
2
0
3
0
4
1
5
0
6
0
7
0
8
0
S
W
132
1
Inhibited to use
0
2
0
3
1
4
0
5
0
6
0
7
0
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7  SOFT SWITCH  7 - 27
3. Soft switch descriptions
SW1 No.1–No.8 Country information
Destination setup
SW2 No.1, No.2 SIM language information
SIM language selection
SW2 No.3–No.8 Language information
Language selection
SW3 No. 1 Sharp machine mode
Sharp machine mode setup
Default: 1 (ON)
SW3 No. 2 Sharp machine mode (F code)
Sharp machine mode (F code) setup
Default: 0 (OFF)
SW3 No. 3 FAST mode
Used to set Enable/Disable of FAST operation. (SEC only)
This SW must be set to enable FAST operation by the serviceman.
Default: 0 (NO)
SW3 No. 4 Center number in FAST
Center number setup in FAST
Default: 0 (Service-No.)
SW3 No.5–No.7 Maintenance cycle
Setup for judgment of consumable parts notification when using the
F.A.S.T. function.
This setup should be the same as SIM21-1 setup.
Default: 0 0 1 (75K)
SW3 No. 8 Maintenance system
Setting of the machine model for judgment of consumable parts sys-
tem in the FAST function
Default: 0 (AR)
SW4 No.1–No.8 Inhibited to use.
SW5 No. 1 Initialization control inside program
Used to set whether the all soft switches are initialized or not.
When set to 1, the initialization is made.
When set to 0, No initialization is made.
Default: 0 (nothing is made)
SW5 No. 2 For FAX debug
Used to set ON/OFF of FAX debug mode.
When set to 1, debug mode is ON.
When set to 0, debug mode is OFF.
Default: 0 (Debug mode OFF)
SW5 No. 3 Flash memory check measuring range
Operation check usually can be done by 256-byte check. Setting to 1
will check all areas of the flash memory. Note that it takes about 20
min.
Default: 0 (256 bytes)
SW5 No. 4 ICU UART1 output
Used to set whether ICU UART 1 output is made or not.
Default: 1 (Output is not made)
SW5 No.5–No.8 24V reset wait time
Used to set  the 24V reset wait time.
The set range is 0 to 750 by binary input.
Default: 500ms
SW6 No. 1 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power. (When no external telephone is connected, do not select Man-
ual. However, setup is possible and reception can be made by on-
hook.)
When set to 1, manual reception.
When set to 0, auto reception.
Default: 0 (Auto reception)
SW6 No. 2 Inhibited to use.
SW6 No.3, No.4 Size specification
Used to set inch series or AB series for recording paper when printing
received documents.
Normally there is no need to change from “Follow the machine infor-
mation.”
Default: 0 1 (follows the machine information)
SW6 No. 5 Inhibited to use.
SW6 No. 6 Memory transmission/direction transmission 
default setup
Used to select Memory/Direction transmission when the power is
turned on and the time out is cleared.
When set to 1, direct transmission is selected when the power is turned
on and the time out is cleared.
When set to 0, memory transmission is selected when the power is
turned on and the time out is cleared.
Default: 0 (Memory transmission)
SW6 No. 7 Quick memory transmission 
Used to set whether quick memory transmission (transmission of ring-
ing before completion of scanning) is performed or not. Linked with the
key operator program menu.
Default: 1 (Allowed)
S
W
133
1
Inhibited to use
0
2
0
3
1
4
1
5
0
6
0
7
0
8
0
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
AR-FX7  SOFT SWITCH  7 - 28
SW6 No. 8 Remote reception instruction
Used to set whether the remove switching function is allowed or not.
When set to 1, the function is allowed.
When set to 0, the function is not allowed.
Default: 1 (Allowed)
SW7 No.1–No.8 Remote selection number setup
Used to set the number by binary input for remote switch reception
from an external telephone. "**" in a remote switch number (X**) is
fixed.
When 10 or greater value is entered, the operations will be the same
as setup of 5.
Default: 5
SW8 No.1–No.3 Image quality priority selection
Used to set the initial value of image selection when scanning a docu-
ment.
When set to 1 0 0, the same operation as standard mode.
Default: 0 0 0 (standard)
SW8 No.4–No.8 Density default setup
Used to set the default density setup of the operation panel.
Default: 0 0 0 0 0 (automatic)
SW9 No. 1 Inhibited to use.
SW9 No. 2 Transfer function
Used to set whether transfer function is allowed or not.
Default: 1 (allowed)
SW9 No. 3 Relay broadcast function
Used to set whether the interface broadcasting command is received
from the other party to perform interface broadcasting or the interface
broadcasting command is not received from the other party. 
When set to 1, the relay broadcast instruction from the allowed party is
received.
When set to 0, the relay broadcast instruction even from the allowed
party is not received.
Default: 1 (The relay broadcast instruction is received.)
Though this function is set to disable, the interface broadcasting com-
mand can be sent.
SW9 No. 4 – No.5 Inhibited to use.
SW9 No. 6 Cover function default setup
Used to set whether the cover is added or not in transmission.
When set to 1, the cover is added.
When set to 0, the cover is not added.
Default: 0 (The cover is not added.)
SW9 No. 7 Specified number reception
Used to set ON//OFF the function to reject the fax reception from the
specified numbers.
Default: 0 (Ignore specified number reception)
SW9 No. 8 Specified number reception in manual 
reception
Used to set whether reception from manual reception is rejected or not
when reception function by specifying the number is ON.
Default: 1 (Reject specified number reception)
SW10 No. 1 F-code relay broadcast function
Used to set whether F code relay broadcast instruction from the other
party is received and relay broadcast transmission is performed or F
code relay broadcast instruction is not received (though the relay box
number by SUB coincides with) from the other party.
Though this function is set to disable, F code instruction can be trans-
mitted.
Default: 0 (Allowed)
SW10 No. 2 F-code confidential reception
Used to set whether F-code confidential instruction is received or not
(though the confidential box number by SUB coincides with) from the
other party.
Though this function is set to disable, F code transmission can be
made.
Default: 0 (Allowed)
SW10 No. 3 Yes/No of SUB capacity in reception
Used to set notification of YES/NO of DIS signal Bit 49 SUB capacity.
"1": No
"0": Yes
Default: 0 (YES)
If set to “1” (NO), the F code transmission from the other party can be
inhibited. 
SW10 No. 4 Yes/No of SEP capacity in reception
Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.
"1": Inhibited
"0": Allowed
Default: 0 (allowed)
When set to 1 (NO), F code polling is inhibited.
SW10 No. 5 Yes/No of reception PWD capacity
Used to set whether password function is judged or not for F code bul-
letin board polling.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
Default: 0 (Password is judged.)
SW10 No. 6 Yes/No of SID capacity in reception
Used to set whether password is judged or nor in F code reception.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
Default: 0 (Password is judged.)
SW10 No. 7 Judgment  of the system number of bulletin 
board transmission
Used to set whether the condition of coincidence between the system
number of this machine and that of the other party machine is
employed as a criterion to judge whether to allow bulletin transmission
by receiving polling transmission from the other party machine made
by our company. 
"1": When the system number of the other party machine made by our
company coincide with the system number of this machine, poll-
ing is allowed.
"0": Though the system number of the other party machine made by
our company coincide with the system number of this machine,
polling is inhibited.
Default: 0 (Inhibited)
AR-FX7  SOFT SWITCH  7 - 29
SW10 No. 8 Send request protection
Used to set YES/NO of the confidential protection function (inhibition of
transmission to an erroneous party). Confidential protection is per-
formed by collating the number registered in this machine and that in
the other party’s machine. (Sender’s telephone number 
 Send
request allow number, System number 
 ID number)
When set to 1, protection is not made.
When set to 0, protection is made.
Default: 0 (Protection)
SW11 No. 1, No. 2 Inhibited to use.
SW11 No. 3 Sender’s telephone number registration
Used to set whether the registered sender’s TEL No. can be changed
or not.
When set to 1, sender’s TEL No. cannot be registered and changed.
To prevent sender’s TEL No. from being changed erroneously, this is
set to 1.
Default: 0 (Enabled)
SW11 No. 4 Yes/No of manual send selection menu 
display
Used to set whether the manual transmission selection screen is dis-
played or not.
Default: 1 (displayed)
SW11 No.5–No.8 Inhibited to use.
SW12 No. 1 Direct send recall Allow/Inhibit
Used to set Allow/Inhibit of direct send recall.
Default: 0 (Inhibited)
SW12 No.2 Manual/Auto reception auto swiching 
(Inhibited except for France.)
Used to set whether automatic reception is made or not when ringing is
made the number of auto switch call times in manual reception.
Default: 0 (Inhibited)
SW12 No.3–No.6 Number of auto switch calls of manual 
reception 
 auto reception (Inhibited except for France.)
When the above setup is allowed, automatic reception is made at the
set number of times.
The set range is 1 to 9 times.
Default: 9 times
SW12 No.7 Inhibited to use.
SW12 No.8 Remote selection models
Used to set remote selection models.
Default: 0 (Call-in only)
SW13 No.1–No.4 Recall times in busy
Used to set the number of recall times in case of busy state of the other
party or when call does not reach the other party.
Setup is made in the range of 0 – 10 times by binary input.
When set to 0, recall is not made.
Default: 2 times of recall
SW13 No.5–No.8 Recall interval in busy
Used to set recall interval after disconnection due to the busy state of
the other party or no response.
The set range is 1 to 15 min in the increment of 1 min by binary input.
When set to 0, it is the same as setup of 3 min.
Default: 3 min
SW14 No.1–No.4 Recall number in case of a transmission 
error
Used to set the number of recall times in case of a communication
error.
Setup is made in the range of 0 – 5 times by binary input.
When set to 0, recall is not made.
Default: 1 time of recall
SW14 No.5–No.8 Recall interval in communication error
Used to set recall interval after disconnection of communication due to
a communication error in memory transmission.
The set range is 0 to 15 min in the increment of 1 min by binary input.
When set to 0, recall is made immediately after disconnection.
However, the time interval set by SW41-5–8 (Interval between the end
of a communication and the next call) is taken.
Default: 1 min
SW15 No. 1 – No.3 Inhibited to use.
SW15 No.4–No.8 Signal send level
Used to set the attenuation quantity of signal send level from the
modem.
0 (0dBm) to 26 (–26dBm)
Default: –8dBm
SW16 No.1–No.4 Modem speed (V.33 mode or less)
Used to set the speed to start communication. When communication
troubles occur frequently, the speed may be reduced to solve the trou-
bles. 
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.5, No.6 Modem speed in reception fixed
Used to set the start speed of reception procedure when receiving from
the other party other than V.34.
When set to "no fixing," the operations are the same as V.17-
14400BPS.
The above four setups are possible. The reception procedure is started
at the set communication speed.
Default: 0 0 (no fixing) Reception is made at the proper communication
speed.
SW16 No. 7 EOL detection timer
Used to set the detection timer of EOL (End Of Life) when Phase-C
reception.
When set to 1, the timer is set to 25sec.
When set to 0, the timer is set to 13sec.
Default: 0 (13 sec)
SW16 No. 8 RTN EOL send times
Used to set the RTN EOL send times.
Default: 1 (6 times)
SW17 No. 1 Inhibited to use.
SW17 No. 2 MH fixed (except for SG3)
Used to set whether the encoding system is fixed to MH or not in a
mode other than SG3 communication.
When set to 1, the encoding system is fixed to MH.
When set to 0, the encoding system is not fixed to MH.
Default: 0 (The encoding system is not fixed to MH.)
bit
5
6
0
0
: No fixing
0
1
: V.29-9600BPS
1
0
: V.27ter-4800BPS
1
1
: V.17-14400BPS
Page of 104