DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE

Model
AR-FX7
Pages
104
Size
4.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARFX7-Service Manual
File
ar-fx7.pdf
Date

Sharp AR-FX7 Service Manual ▷ View online

AR-FX7  SOFT SWITCH  7 - 6
: UK = U.K.,
G = Germany,
F = France
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
UK G
F
S
W
19
1
Minimum pause time 
(10PPS) setup
Binary 
input
Bit No.
Setting range
1
2
3
4
0 (525ms) to 15 (900ms)
X (ms) = (N × 25) + 525
825ms
1
1
1
2
1
1
1
3
0
0
0
4
0
0
0
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
20
1
Inhibited to use
0
0
0
2
PBX setup
(Inhibited except for 
Germany and France.)
Bit  No.
2
3
4
Setup OFF
0
0
0
When the value is 
outside the 
setting range, the 
initial value is set.
3
Setup OFF
0
0
0
0
0
0
4
Flash send
1
0
1
0
0
0
ID send
1
1
0
5
SIM DTMF sound 
speaker selection 
window
1: Yes
0: No
No
0
0
0
6
Flash send wait time
Bit No.
6
7
0sec
(U.K., France)
1sec (Germany)
0
1
0
Fixed to 0 except 
for Germany.
0sec
0
0
0.5sec
0
1
7
1sec
1
0
0
0
0
2sec
1
1
8
Receivable memory 
capacity
1: 64Kbyte
0: 128Kbyte
128Kbyte
0
0
0
S
W
21
1
Dial tone detection
1: Yes
0: No
No
0
0
0
2
Busy tone detection
1: Yes
0: No
Yes
1
1
1
3
Dial tone monitoring 
time
1: 10sec
0: 5sec
5sec
0
0
0
4
CED detection time
1: 500ms
0: 1000ms
1000ms
0
0
0
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
22
1
Waiting time for dial 
start
Bit No.
1
2
3.5sec
0
0
0
3.5sec
0
0
4sec
0
1
2
5sec
1
0
0
0
0
6sec
1
1
3
CNG send start time
Bit No.
3
4
0.5sec
0
0
0
0.5sec
0
0
4
1.0sec
0
1
0
0
0
1.5sec
1
0
5
Tone/pulse default 
setup
Bit No.
5
6
TONE
1
1
1
10PPS
0
0
6
20PPS
0
1
0
0
0
TONE
1
0
7
DPMUTE  control
1: ON
0: OFF
OFF
0
0
0
8
DP dial pulse number 
process
1: 10-N
0: Normal (N)
Normal (N)
0
0
0
S
W
23
1
Inhibited to use
0
0
0
2
Monitoring polarity 
reversion during send 
image
1: Yes
0: No
No
0
0
0
Fixed to No.
3
Monitoring polarity 
reversion during 
communication
1: Yes
0: No
No
0
0
0
Fixed to No.
4
Setting of time before 
dial (10PPS)
Binary 
input
Bit No.
Setting range
4
5
6
7
8
0 (50ms) to 31 (360ms)
X (ms) = (N × 10) + 50
300ms
1
1
1
5
1
1
1
6
0
0
0
7
0
0
0
8
1
1
1
AR-FX7  SOFT SWITCH  7 - 7
: UK = U.K.,
G = Germany,
F = France
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
UK G
F
S
W
24
1
Inhibited to use
0
0
0
2
0
0
0
3
0
0
0
4
0
0
0
5
Waiting time for OFF 
HOOK
Binary 
input
Bit No.
Setting range
5
6
7
8
0 (50ms) to 15 (200ms)
X (ms) = (N x 10) + 50
100ms
0
0
0
6
1
1
1
7
0
0
0
8
1
1
1
S
W
25
1
Make time (10PPS) 
setup
Binary 
input
Bit No.
Setting range
1
2
3
4
26  to 41ms 
by increment of 1ms
34ms
(U.K., France)
41ms (Germany)
1
1
1
2
0
1
0
3
0
1
0
4
0
1
0
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
26
1
DTMF signal send time
Binary 
input
Bit No.
Setting range
1
2
3
4
5
6 (60ms) to 31 (310ms)
X (ms) = (N × 10)
110ms
0
0
0
2
1
1
1
3
0
0
0
4
1
1
1
5
1
1
1
6
Minimum pause time 
(DTMF) setup
Binary 
input
Bit No.
Setting range
6
7
8
0 (90ms) to 7 (160ms)
X (ms) = (N × 10) + 90
120ms
0
0
0
7
1
1
1
8
1
1
1
S
W
27
1
Inhibited to use
0
0
0
2
Setting of time before 
dial (DTMF) 
Binary 
input
Bit No.
Setting range
2
3
4
0 (30ms) to 7 (100ms)
X (ms) = (N × 10) + 30
50ms
0
0
0
3
1
1
1
4
0
0
0
5
Setting of DPMUTE 
OFF time after dial
Binary 
input
Bit No.
Setting range
5
6
7
8
0 (5ms) to 15 (80ms)
X (ms) = (N × 5) + 5
50ms
1
1
1
6
0
0
0
7
0
0
0
8
1
1
1
S
W
28
1
Pause time setup
Binary 
input
Bit No.
Setting range
1
2
3
4
1 to 15sec
2sec
0
0
0
When the value is 
outside the 
setting range, the 
initial value is set.
2
0
0
0
3
1
1
1
4
0
0
0
5
Flash send time
Bit No.
5
6
90ms
0
0
0
Fixed to 0 except 
for Germany and 
France.
90ms
0
0
180ms
0
1
6
270ms
1
0
0
0
0
360ms
1
1
7
Line open delay time in 
dial test
Bit No.
7
8
2sec
0
0
0
2sec
0
0
3sec
0
1
8
4sec
1
0
0
0
0
5sec
1
1
S
W
29
1
Communication record 
table automatic print
1: Yes
0: No
No
0
0
0
2
Time specification of 
communication record 
table
1: Allowed
0: Inhibited
Inhibited
0
0
0
3
Sequence of year, 
month, and day on the 
LCD, the report, and the 
sender’s record
Bit No.
3
4
Day, month, year
1
1
1
When the value is 
outside the 
setting range, the 
initial value is set.
Year, month, day
0
0
Month, day, year
0
1
4
Day, month, year
1
0
0
0
0
1
1
5
Call time setup in 
automatic transmission 
(T0 timer setup)
Binary 
input
Bit No.
Setting range
5
6
7
8
30 to 75sec
by increment of 5sec
45sec
0
0
0
When the value is 
outside the 
setting range, the 
initial value is set.
(Menu setting in 
the unit of 15sec)
6
0
0
0
7
1
1
1
8
1
1
1
AR-FX7  SOFT SWITCH  7 - 8
: UK = U.K.,
G = Germany,
F = France
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
UK G
F
S
W
30
1
Inhibited to use
0
0
0
2
0
0
0
3
0
0
0
4
Time specification print 
(o’clock) on the 
communication record 
table
Binary 
input
Bit No.
Setting range
4
5
6
7
8
00 to 23 o’clock
0 o’clock
0
0
0
When the value is 
outside the 
setting range, the 
initial value is set.
5
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
31
1
Inhibited to use
0
0
0
2
0
0
0
3
Time specification print 
(minute) on the 
communication record 
table
Binary 
input
Bit No.
Setting range
3
4
5
6
7
8
00 to 59 min
0 min
0
0
0
When the value is 
outside the 
setting range, the 
initial value is set.
4
0
0
0
5
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
32
1
Default telephone book 
setup
Bit No.
1
2
Basic screen
0
0
0
Basic screen
0
0
2
Destination list 
(50-character kana 
syllabary
0
1
0
0
0
Destination list 
(user)
1
0
3
Next address key input 
in broadcast
1: Yes
0: No
No
0
0
0
4
One-touch dial display 
number switch
Bit No.
4
5
8 items
0
0
0
6 items
0
0
5
8  items
0
1
1
1
1
12 items
1
0
6
Shift of the power OFF 
state in shut off
1: Allowed
0: Inhibited
Allowed
1
1
1
7
Time indication format
1: AM/PM
0: 24H
24H
0
0
0
8
Priority in the day of 
week
1: Yes
0: No
No (U.K.)
Yes (Germany, 
France)
0
1
1
S
W
33
1
Inhibited to use
0
0
0
2
Report output on less 
than A4 (LTR)
1: Reduction as A4 (LTR) 
images
0: Reduction by the record 
volume
Reduction by the 
record volume
0
0
0
3
Own  FAX  No.  mark  of 
TX image (English only)
1: TEL icon (
)
0: “FAX:”
“FAX:”
0
0
0
4
Contents of send 
document are printed in 
memory send error
Bit No.
4
5
When 
transmission is 
failed
1
1
1
Not print
0
0
5
Print all
0
1
0
0
0
When transmission 
is failed
1
0
6
Transmission document 
content print in F code 
transmission
1: Not print
0: Print
Not print
1
1
1
SW33-4 – 5 must 
be set to output.
7
Function to attach 
images to the report 
table of memory 
confidential send
1: Yes
0: No
No
0
0
0
8
Total communication 
time and total number of 
pages print on 
communication record 
table
1: Yes
0: No
Yes
1
1
1
AR-FX7  SOFT SWITCH  7 - 9
SW 
No.
Data 
No.
Items
SW selection and functions
Default value
Remarks
S
W
34
1
Report output (in reception)
Bit No.
1
2
Print is inhibited.
0
Print is inhibited.
0
0
2
Print all
0
1
0
Only in case of an 
error
1
0
3
Report output (in 
transmission)
Bit No.
3
4
Only when 
transmission is 
failed
1
Print is inhibited.
0
0
4
Print all
0
1
0
Only when 
transmission is 
failed
1
0
5
Communication report output 
(in confidential reception)
1: Print
0: Not print
Print
1
6
Report output (In broadcast, 
sequential send request, and 
relay broadcast)
Bit No.
6
7
Print all
0
Print is inhibited.
0
0
7
Print all
0
1
1
Only the address to 
which transmission 
is failed
1
0
8
Report output when canceling 1: Output
0: Not output
Not output
0
S
W
35
1
Automatic reduction print
1: Allowed
0: Inhibited
Allowed
1
2
Paper selection priority
1: Width priority
0: Area priority
Area priority
0
3
Output condition setup
Bit No.
3
4
Reduction 
allowed
0
When the value is 
outside the setting 
range, the initial 
value is set.
Reduction allowed
0
0
AB
0
1
4
Division allowed
1
0
0
A
1
1
5
Automatic reduction rate 
setup
Binary 
input
Bit No.
Setting range
5
6
7
8
0 to 15%
6%
0
6
1
7
1
8
0
S
W
36
1
Waiting time for PC-FAX job 
end
Binary 
input
Bit No.
Setting range
1
2
3
4
0 (32min) to 15 (2 min)
2 min
1
2
1
3
1
4
1
5
Inhibited to use
0
6
0
7
Waiting time for lift-up
Bit No.
7
8
30sec
0
30sec
0
0
15sec
0
1
8
60sec
1
0
0
120sec
1
1
S
W
37
1
Thin paper setup
1: Allowed
0: Inhibited
Inhibited
0
2
Specification of 1m scan 
when there is no line send 
setting 
1: Specification of 1m scan
0: Normal operation
Normal operation
0
3
Rotation send selection (A4 
 A4R)
1: Yes
0: No
Yes
1
4
Rotation transmission 
selection (B5R 
 B5)
1: Yes
0: No
Yes
1
5
Rotation transmission 
selection (A5R 
 A5)
1: Yes
0: No
Yes
1
6
Rotation transmission 
selection (11 x 8.5 
 8.5 x 
11)
1: Yes
0: No
Yes
1
7
Inhibited to use
1
8
Rotation scan word 
calculation
1: Round up
0: Round down
Round down
0
Page of 104
Display