DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

Code
Function (Purpose)
Main
Sub
24
9
Used to clear the printer print counter. (The counter is cleared
after completion of maintenance.)
11
Used to reset the developer rotation time counter. (The
developer counter of the installed developing unit is reset.)
(AR-501/505 only)
25
1
Used to check the operation of the main drive (excluding the
scanner section) and to check the operation of the toner
concentration sensor. (The toner concentration sensor output
can be monitored.)
2
Used to make the initial setting of toner concentration when
replacing developer.
8
Used to set the timing of toner concentration control
correction B and the correction quantity. The timing is
determined according to the acuumulated use time of
developer. (AR-501/505 only)
26
1
Used to set options. (This simulation is used to make option
setting when an option is installed.)
2
1) Used to set the paper size of the large quantity paper 
   tray. (When the paper size is changed, the lift paper 
   size must be also changed with this simulation.)
2) Used to detect the paper or document size of 8.5" x 
   13" (Inch series) and set the display mode. (All paper 
   feed modes)
3
Used to set the specifications of the auditor. Setting must be
made depending on the use condition of the auditor.
5
Used to set the count mode of the total counter and the
maintenance counter.
6
Used to set the specifications depending on the destination.
15
Used to set the fusing operation mode (paper curl
corresponding mode).
18
Used to set VALID/INVALID of toner save operation. (This
simulation is valid only in the Japan and UK versions. (It
depends on SIM 26-6 (Destination setting). For the other
destinations, the same setting can be executed with the user
program.)
22
Used to set the specification (language display) for the
destination. (Excluding the Japan models.)
30
Used to set the CE mark conforming operation mode.
(For flickers when driving the fusing heater lamp.)
35
Used to set whether the trouble history display of SIM 22-4 is
displayed as one trouble or as the number of continuous
troubles when two or more troubles of a same kind occured.
36
Used to set the ICU fan operating temperature. (Operation in
the pre-heat mode.) (Excluding Japan models.)
40
Polygon motor stop mode setup (AR-501/505)
Used to set the stop time of the polygon motor after leaving in
ready state and to set Enable/Disable of the setting.  (Other
models)
41
Used to enable/disable the auto magnification ratio select
(AMS) function in the pamphlet copy mode.
44
Used to set the model of the unit which is connected to the
SCSI I/F of ICU PWB.
50
Used to set YES/NO of black/white reversion is allowed.
52
Used to set whether white paper discharge count up is
performed or not.
("White paper" means insertion paper in the OHP insertion
paper mode (without copy), cover paper in the cover paper
insertion mode (without copy)/back cover, and white paper in
the duplex exit mode (CA etc.).)
27
1
Used to set the operation  specifications when a
communication trouble occurs between the host computer
and MODEM (on the copier). (When a communication trouble
occurs between the host computer and MODEM (copier), the
self diag display (U7-00) is printed and setting is made to
select inhibit/allow of printing.)
2
Used to set and change the host computer/MODEM
numbers. (This setting is required when a communication is
made between the copier and a computer through MODEM.)
3
Used to set and change the ID numbers of the copier and the
host computer/MODEM numbers. (This setting is required
when a communication is made between the copier and a
computer through MODEM.)
Code
Function (Purpose)
Main
Sub
27
4
Used to enter the start time and the end time of servicing for
management of service work. (The data can be checked by
the host computer.)
5
Used to enter the TAG No. of the copier. (This simulation
allows to check the machine TAG No. with the host
computer.)
30
1
Used to check the operation of sensors and detectors in the
paper feed section, the paper transport section, and the
paper exit section, and the related circuit.
2
Used to check the operation of sensors and detectors in the
paper feed section and the related circuits. 
(The operations of sensors and detectors in the paper feed
section can be monitored with the LCD.)
40
1
Used to check the operation of the manual paper feed tray
paper size detector and the related circuit. (The operation of
the manual paper feed tray paper size detector can be
monitored with the LCD.)
2
Used to adjust the manual paper feed tray paper width
detector detection level.
41
1
Used to check the operation of the document size sensor and
the related circuit. (The operation of the document size
sensor can be monitored with the LCD.)
2
Used to adjsut the document size sensor detection level.
3
Used to check the operation of the document size sensor and
the related circuit. (The document size sensor output level
can be monitored with the LCD.)
43
1
Used to set the fusing temperature in each operation mode.
3
Used to adjust the fusing motor speed. (AR-501/505 only)
8
Used to set the time to rotate the fusing motor after reaching
the set temperature in warming up. (AR-501/505 only)
44
1
Used to set whether the correction functions of the image
forming (process) section are valid or not.
2
Used to adjust the sensitivity (gain) of the OPC drum mark
sensor and the image density sensor.
4
Used to set the target image (reference) density level in the
developing bias voltage correction.
5
Used to set various parameters (main charger grid voltage,
laser beam power, correction start developing bias voltage) in
developing bias correction.
9
Used to check the data on the result of the image forming
section correction (process correction) (the corrected main
charger grid voltage in each print mode, developing bias
voltage, the laser power, etc.)
(This simulation allows to check whether the correction is
executed properly or not.)
12
Used to check the toner image patch density date in
correction operation of the image forming section. (This
simulation allows to check whether the correction is executed
properly or not. )
15
Used to set the correction values of various parameters
(maincharger grid voltage, laser beam power, developing bias
voltage) in the image forming operation and image forming
section correction for OPC drum type A.
(AR-250/280/281/285/286/335/336/405 only)
46
2
Used to adjust the copy density in the copy mode
(binary/multi-value - auto, character and photo, photo mode). 
(The overall print density in each mode (all of the specified
density set for each density level (display value)) can be
adjusted in each mode.)
3
Used to adjust the copy density in the copy mode (multi
value-auto, character and photo, photo mode). 
(The overall print density in each mode (all of the specified
density set for each density level (display value)) can be
adjusted in each mode.) (AR-250/280/285/330/335 only)
5
Used to adjust the print density for each density level (display
value) in the copy mode (multi character mode).
An arbitrary print density can be set for each density level
(display value). (AR-250/280/285/330/335 only)
6
Used to adjust the print density for each density level (display
value) in the copy mode (multi value-character, photo mode). 
An arbitrary print density can be set for each density level
(display value). (AR-250/280/285/330/335 only)
AR-505
10/8/1999
7 – 4
Code
Function (Purpose)
Main
Sub
46
7
Used to adjust the print density for each density level (display
value) in the copy mode (multi value - photo mode). (Japan
only)
9
Used to adjust the print density for each density level (display
value) in the copy mode (binary - character mode). 
46
10
Used to adjust the print density for each density level (display
value) in the copy mode (binary - character, photo mode). 
An arbitrary print density can be set for each density level
(display value).
11
Used to adjust the print density for each density level (display
value) in the copy mode (binary -  photo mode). 
An arbitrary print density can be set for each density level
(display value).
17
Used to execute shading correction and display the correction
value.
18
Used to adjust 
γ
 (density gradient) in each copy mode.
(Target models: AR-2X1/3X1/4XX/250/XX6/5XX series)
19
Used to adjust 
γ
 (density gradient) and set the density
detection area in the auto copy mode and to set the image
process mode in the photo copy mode. (Target models:
AR-2X1/3X1/4XX/250/XX6/5XX series)
20
Used to adjust the copy density correction in the SPF (RSPF)
copy mode for the document table copy mode. Adjustment is
made so that the copy density is the same as that in the
document table copy mode. (Target models:
AR-2X1/3X1/4XX/250/XX6/5XX series)
48
1
Used to adjust the copy magnification ratio (main scanning
direction, sub scanning direction).
50
1
Used to adjust the copy image position and the void area
(image loss) on the print paper in the copy mode. (The same
adjustment can be made with SIM 50-2 (simple method).)
2
Used to adjust the copy image position and the void area
(image loss) on the print paper in the copy mode. (Simple
adjustment)
(This simulation allows the same simulation with SIM 50-1
more simply. )
5
Used to adjust the print image position (top margin) on the
print paper in the print mode.
6
Used to adjust the copy lead edge. (RSPF)
7
Used to adjust the copy lead edge (simple method). (RSPF)
10
Used to adjust the print image center position. (Adjustment
can be made for each paper feed section.)
12
Used to adjust the print image center position. (Adjustment
can be made for each document mode.)
26
Used to set the folding margin of center binding.
51
1
Used to adjust the OPC drum separation pawl ON timing.
2
Used to adjust the contact pressure of paper onto the resist
roller in each section (copier paper feed section, duplex paper
feed section, SPF paper feed section). 
(When the print image position varies greatly for the paper or
when a lot of paper jam troubles occur, the adjustment is
required.)
8
Used to set Enable/Disable of the drum separation pawl drive
solenoid (PSPS) operation for each paper feed section.
(AR-501/505 only)
52
1
Used to adjust the duplex print mode stacking capability.
(Used to adjust the stop position of the paper tray width
direction alignment plate in the duplex unit.  The adjustment
is executed by changing the width direction alignment plate
home position in the software.)
53
1
Used to adjust the document stop position in each operation
mode of ADF/RADF. (Target model:
AR-250/280/285/335/405)
2
Used to adjust the optical sensor sensitivity in the
ADF/RADF. (Target models:
AR-250/280/285/335/405/501/505)
6
Used to adjust the RSPF width detection level. (AR-501/505
only)
60
1
Used to check the operation (read/write) of ICU (DRAM).
(SIMM MEMORY/ONBOARD MEMORY)
61
1
Used to test the operation of the scanner (exposure) unit.
Code
Function (Purpose)
Main
Sub
61
2
Used to adjust the scanner (exposure) laser power (absolute
value) in the copy mode.
4
Used to adjust the scanner (exposure) laser power (absolute
value) in the printer mode. (For Photoconductor type B)
62
1
Used to format the hard disk. (Target models:
AR-250/280/285/335)(Models with the hard disk installed only)
2
Used to check the operation (read/write) of the hard disk.
(Target models: AR-250/280/285/335)(Models with the hard
disk installed only.) (Partial check)
62
3
Used to check the operation (read/write) of the hard disk.
(Target models: AR-250/280/285/335) (Only the models with
a hard disk) (All area check)
63
1
Used to check the result of shading correction. (The shading
correction data are displayed.)
7
Used to adjust the white plate scanning start position in the
shading white correction. (AR-501/505 only)
64
1
Used to check the operation of the printer function (auto print
operation). (Print pattern, paper feed mode, print mode, the
number of sheets, and the density can be set to an arbitrary
value.)
65
1
Used to adjust the touch panel (LCD display) detecting
position.
2
Used to check the result of the touch panel (LCD display)
detecting position adjustment. (The coordinates are
displayed.)
67
1
Used to check the printer PWB memory operation
(read/write). (When replacing the PWB with a new one, this
check must be performed.)
2
Used to check the printer parallel I/F operation. (This
simulation is used only for production, and a special tool is
required. Not available in the market.)
3
Used to adjust the printer parallel I/F ACk signal width.
11
Used to set YES/NO of the printer parallel I/F SELECT IN
signal.
12
Used to write data into the printer flash memory.
13
Used to check the printer flash memory data.
14
Used to check the printer flash memory data writing and its
result.
15
Used to check the sum of the printer flash memory.
16
Used to check the operation of the network card.
17
Used to clear data in the NVRAM of the printer PWB (set to
the default). (Printer set data)
68
1
Used to check the operation of infrared communication I/F
(Zaurus link) and the related circuit. (Target models:
AR-F230/S280/F280S/F280R/S330)(Japan models only)
69
1
Used to check the input/output by connecting channels A and
B of SCSI with the SCSI cable. (AR-501/505 only)
AR-505
7 – 5
10/8/1999
C. Details of simulations
1
1 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the scanner unit and its
control circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio with
the zoom key.
The magnification ratio can be increased or
decreased with the [ZOOM] key by the increment of
1%.
The selected magnification ratio is displayed on the
magnification ratio display.
2. Press the [EXECUTE] key.
Scanning is performed at the magnification ratio set in proce-
dure 1 is executed. During scanning, the [EXECUTE] key is
highlighted.
If the [EXECUTE] key is pressed under this state, the opera-
tion is interrupted. After completion of scanning, the [EXE-
CUTE] key returns to the normal display.
To resume scanning, start with procedure 2.
To change the magnification ratio, start with procedure 1.
Scanning is performed at the max. scanning length (432mm). If,
however, the magnification ratio is set to greater than 100%, the
scanning length is changed accordingly.
1 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the scanner section and the related circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the scanner
section are displayed.
The active sensors and detectors are highlighted.
2
2 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the RADF unit and its
control circuit.
Section
SPF/ADF/RSPF/RADF
Item
Operation
Operation/
Procedure
1. Select the aging mode with the key.
When selection is made, the selected item is
highlighted.
[1:SIDE]: Single copy aging mode
[2:SIDE] Duplex copy aging mode
(Note) [2:SIDE] is displayed only when the unit
which allows duplex copy is installed.
2. Select the copy magnification ratio with the key.
(The magnification ratio can be increased or decreased in the
increment of 1% with the [ZOOM] key.)
The selected magnification ratio is displayed on the magnifica-
tion ratio display on the screen.
The magnification ratio can be set only when SPF is installed.
3. Press the [EXECUTE] key.
Aging of the document feeder is executed under the conditions
specified with procedures 1 and 2.
During aging, the [EXECUTE] key is highlighted. If the [EXE-
CUTE] key is pressed while it is highlighted, the operation is in-
terrupted.
When two or more operations are selected in procedure 1,
"1:SIDE" (single copy aging mode) is unconditionally per-
formed and the other highlighted displays return to the normal
display.
To resume aging, execute with procedure 3.
To change the conditions for aging, execute with procedure 1.
*
When the SPF is installed , the magnification ratio can be
adjusted in the range of 64% - 200%.
2 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the RADF units and the related circuit.
Section
SPF/ADF/RSPF/RADF
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the
RADF/ADF/SPFsection are displayed.
The active sensors and detectors are highlighted.
[ADF/RADF installed]
DSS
Empty sensor
Normal display:
Document empty
Highlighted display:
Document exist
DFD
Resist sensor
Normal display:
Document empty
Highlighted display:
Document exist
DTD
Paper timing
sensor
Normal display:
Document empty
Highlighted display:
Document exist
AR-505
8/6/1999
7 – 6
AUOD
DF open/close
sensor
Normal display:
Close
Highlighted display:
Open
TSS1
Tray feed size
sensor (large
size)
Normal display:
Document empty
Highlighted display:
Document exist
TSS2
Tray feed size
sensor (small
size)
Normal display:
Document empty
Highlighted display:
Document exist
DWS1
Tray width
sensor (182mm)
Normal display:
OFF
Highlighted display:
ON
DWS2
Tray width
sensor (210mm/
215.9mm)
Normal display:
OFF
Highlighted display:
ON
DWS3
Tray width
sensor (257mm)
Normal display:
OFF
Highlighted display:
ON
DWS4
Tray width
sensor
(279.4mm)
Normal display:
OFF
Highlighted display:
ON
DWS5
Tray width
sensor (297mm)
Normal display:
OFF
Highlighted display:
ON
RDD
Paper exit
sensor
Normal display:
OFF
Highlighted display:
ON
[SPF installed]
DSS empty sensor
Normal display:
Document empty
Highlighted display:
Document exist
DFD resist sensor
Normal display:
Document empty
Highlighted display:
Document exist
RDD paper exit sensor
Normal display:
Document empty
Highlighted display:
Document exist
AUOD DF open/close
sensor
Normal display:
Close
Highlighted display:
Open
TSS1 tray feed size
sensor (large size)
Normal display:
Document empty
Highlighted display:
Document exist
TSS2 tray feed size
sensor (small size)
Normal display:
Document empty
Highlighted display:
Document exist
DWS1 tray width
sensor (182mm)
Normal display:
OFF
Highlighted display: ON
DWS2 tray width sensor
(210mm/215.9mm)
Normal display:
OFF
Highlighted display: ON
DWS3 tray width
sensor (257mm)
Normal display:
OFF
Highlighted display: ON
DWS4 tray width
sensor (279.4mm)
Normal display:
OFF
Highlighted display: ON
DWS5 tray width
sensor (297mm)
Normal display:
OFF
Highlighted display: ON
[RSPF installed]
EMP
Empty sensor
Normal display:
Document empty
Highlighted display:
Document exist
BUNRIS
Post-separation
sensor
Normal display:
Document empty
Highlighted display:
Document exist
RDS
Read sensor
Normal display:
Document empty
Highlighted display:
Document exist
RDD
Paper exit
sensor
Normal display:
Document empty
Highlighted display:
Document exist
SBS
Switch-back
sensor
Normal display:
Document empty
Highlighted display:
Document exist
REGS
Resist sensor
Normal display:
Document empty
Highlighted display:
Document exist
AU0D
DF open/close
sensor
Normal display:
Close
Highlighted display:
Open
FG0D
Paper feed
cover sensor
Normal display:
Close
Highlighted display:
Open
TSS1
Tray feed size
sensor (large
size)
Normal display:
Document empty
Highlighted display:
Document exist
TSS2
Tray feed size
sensor (small
size)
Normal display:
Document empty
Highlighted display:
Document exist
DWS1
Tray width
sensor (182mm)
Normal display:
OFF
Highlighted display:
ON
DWS2
Tray width
sensor
(210mm/8.5")
Normal display:
OFF
Highlighted display:
ON
DWS3
Tray width
sensor (257mm)
Normal display:
OFF
Highlighted display:
ON
DWS4
Tray width
sensor (17")
Normal display:
OFF
Highlighted display:
ON
DWS5
Tray width
sensor (297mm)
Normal display:
OFF
Highlighted display:
ON
2 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the loads in the
RADF/ADF/SPF units and the control circuits.
Section
SPF/ADF/RSPF/RADF
Item
Operation
Operation/
Procedure
1. The names of the loads which can be operated are
displayed. Select the load to be checked with the
key, and the selected load is highlighted.
2. Press the [EXECUTE] key.
The load selected in procedure 1 starts the operation. During
the operation of the load, the [EXECUTE] key is highlighted. If
the EXECUTE key is pressed while it is highlighted, the opera-
tion is stopped.
When two or more operations are selected in procedure 1, the
operation is performed in the sequence of display order.
[When ADF/RADF is installed]
DFM FORWARD
Paper feed motor forward rotation
DFM REVERSE
Paper feed motor reverse rotation
DTM FORWARD
Transport motor forward rotation
DTM REVERSE
Transport motor reverse rotation
DRM
Paper expulsion motor
DFSOL
Paper feed solenoid
[When SPF is installed]
DTM FORWARD
Transport motor forward rotation
DTM REVERSE
Transport motor reverse rotation
STAMP SOL
Stamp solenoid
[When RSPF is installed]
DFM FORWARD (L)
Paper feed motor forward rotation
(230mm/sec)
DFM REVERSE (L)
Paper feed motor reverse rotation
(360mm/sec)
DFM FORWARD (H)
Paper feed motor forward rotation
(450mm/sec)
DFM REVERSE (H)
Paper feed motor reverse rotation
(450mm/sec)
DTM
Transport pulse motor
DFC
Paper feed clutch
FSOL1
Flapper solenoid 1
FSOL2
Flapper solenoid 2
SBSOL
Switchback pressure solenoid
AR-505
7 – 7
8/6/1999
Page of 51