DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

27
27 - 1
Purpose
Setting
Function
(Purpose)
Used to set the operation  specifications when a com-
munication trouble occurs between the host computer
and MODEM (on the copier). (When a communication
trouble occurs between the host computer and MO-
DEM (copier), the self diag display (U7-00) is printed
and setting is made to select inhibit/allow of printing.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
Enter the code number corresponding to the operation
mode with the 10-key and press the [OK] key.
Used to set Enable/Disable of U7-00 trouble detection.
Set value
Content
0
U7-00 trouble detection is disabled.
(Default)
1
U7-00 trouble detection is enabled.
0: Though a communication trouble occurs between the host
computer and the MODEM (machine side), the operation of the
machine is not affected.
1: When a communication trouble occurs between the host com-
puter and the MODEM (copier side), the self diag display (U7-
00) is shown and printing is inhibited.
27 - 2
Purpose
Setting
Function
(Purpose)
Used to set and change the host computer/MODEM
numbers. (This setting is required when a communica-
tion is made between the copier and a computer
through MODEM.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
User data
Operation/
Procedure
1. Select the PC/MODEM(HOST#/TEL#)to be set or
changed. ’The selected key is highlighted.)
2. Press the [OK] key.
The key is highlighted and inquiring of the present set number
of the selected PC/MODEM is made to the host computer.
(When the number is supplied from the host normally.)
The present set number is displayed in the column of PRE-
SENT (or no display is made if not registered) and the [OK] key
at the upper right returns from the gray display to the normal
display.
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of PRESENT and
the OK key at the lower right returns from the highlight display
to the normal display.
3. When changing the number, enter the new number (max. 24
digits) with the 10-key and the following keys.
# : [P]((program) key
* : [AUDIT CLEAR] ((Dept. count end) key
, : [ i ]((Information) key
4. When the [OK] key at the upper right is pressed, the newly set
number for the selected PC/MODEM is registered.
(When registered normally)
The number displayed in the column of NEW disappears and
the newly set number appears in the column of PRESENT
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of NEW.
Note
For this setting, the copier and the host computer must
be connected with a communication line (MODEM).
27 - 3
Purpose
Setting
Function
(Purpose)
Used to set and change the ID numbers of the copier
and the host computer/MODEM numbers. (This setting
is required when a communication is made between
the copier and a computer through MODEM.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
User data
Operation/
Procedure
1. Select between PPC(copier) and PC/MODEM(host).
The key is highlighted.
2. Press the [OK] key at the lower right. (The key is highlighted
and an inquiry of the selected ID No, to the host.)
(When the number is supplied from the host normally)
The present set number is displayed in the column of PRE-
SENT (or no display is made if not registered) and the [OK] key
at the upper right returns from the gray display to the normal
display.
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of PRESENT and
the OK key at the lower right returns from the highlight display
to the normal display.
3. When changing the number, enter the new number (max. 24
digits) with the 10-key and the following keys.
X: [P](program) key
Y: [AUDIT CLEAR](dept. count end) key
The entered number is displayed in the column of "NEW"
4. When the [OK] key at the upper right is pressed, the newly set
ID number of the selected PC/MODEM is registered on the
host side.
(When registered normally)
The number in the column of NEW disappears and the newly
set and registered number appears in the column of PRE-
SENT.
(In case of a trouble)
"Failed (U7-00) " is displayed in the column of NEW
Note
For this setting, the copier and the host computer must
be connected with a communication line (MODEM).
AR-505
10/8/1999
7 – 28
27 - 4
Purpose
Setting
Function
(Purpose)
Used to enter the start time and the end time of servic-
ing for management of service work. (The data can be
checked by the host computer.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
Operation/
Procedure
1. Press the[SERVICE START]key when starting serv-
icing.
The key is highlighted.
2. Press the [EXECUTE]key.
The key is highlighted and the data on service start time is
sent.
3. Press the [SERVICE END]Key after completion of servicing.
The key is highlighted.
4. Press the [EXECUTE]key .
The key is highlighted and the data on service end time is sent.
When the host receives the data normally,"Complete"is high-
lighted.
In case of a trouble, "Failed"is highlighted. 
Note
For this setting, the copier and the host computer must
be connected with a communication line (MODEM).
27 - 5
Purpose
Setting
Function
(Purpose)
Used to enter the TAG No. of the copier. (This simula-
tion allows to check the machine TAG No. with the host
computer.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
Operation/
Procedure
1. When entering the tag No. newly or changing the tag
No. enter the value (max. 8 digits) with the 10-key.
The entered number is displayed in the column of
"NEW"
2. Press the [OK] key.
The new tag No. entered in procedure 1 is set.
It is advisable to enter the machine’s SER No. for machine
management and servicing. 
Note
For this setting, the copier and the host computer must
be connected with a communication line (MODEM).
30
30 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the paper feed section, the paper transport section,
and the paper exit section, and the related circuit.
Section
Others
Item
Operation
Operation/
Procedure
The operations of the sensors and detectors in the sec-
tions other than the paper feed section of the copier are
displayed.
The active sensors and detectors are highlighted.
DSWF
Copier front door open/close
DSWL
Copier left door
DSWLL
Copier left lower door
DSWR
Copier right door
DVCH1
Developing unit installation detection
DVCH2
Developing unit installation detection
DVCH3
Developing unit installation  detection
DVCH4
Developing unit installation detection
PFD
Paper vertical transport sensor
PPD1
Paper transport sensor 1
PPD2
Paper transport sensor 2
PSD
Paper transport sensor
POD1
Paper exit sensor 1
POD2
Paper exit sensor 2
POD3
Paper exit sensor 3
TFD
Waste toner bottle full detection
TMS
Toner motor missing detection
(AR-501/505)
(Other models)
30 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the paper feed section and the related circuits.
(The operations of sensors and detectors in the paper
feed section can be monitored with the LCD.)
Section
Paper transport
Item
Operation
Operation/
Procedure
The operations of the sensors and detectors in the pa-
per feed section of the copier are displayed.
The active sensors and detectors are highlighted.
UCSS1
Copier upper tray paper size detection 1
UCSS2
Copier upper tray paper size detection 2
UCSS3
Copier upper tray paper size detection 3
UCSS4
Copier upper tray paper size detection 4
LUD1
Copier upper tray upper limit detection
PED1
Copier upper tray paper detection
UCSPD1
Copier upper tray paper size detection
LCSS1
Copier lower tray paper size detection 1
AR-505
7 – 29
10/8/1999
LCSS2
Copier lower tray paper size detection 2
LCSS3
Copier lower tray paper size detection 3
LCSS4
Copier lower tray paper size detection 4
LUD2
Copier lower tray paper detection
PED2
Copier lower tray paper detection
LCSPD1
Copier lower tray paper size detection
MPLS1
Manual tray length detection 1
MPLS2
Manual tray length detection 2
MPLD1
Manual feed paper length detection 1
MPLD2
Manual feed paper length detection 2
MPED
Manual tray paper empty detection
One of
theseis
displayed

 
 
 
 
 
 
 
 
 
 
A4/A3
Manual tray (width only) detection size
11x
Manual tray (width only) detection size
B5/B4
Manual tray (width only) detection size
8.5x
Manual tray (width only) detection size
A5/A4R
Manual tray (width only) detection size
B5R
Manual tray (width only) detection size
POSTCARD Manual tray (width only) detection size
EXTRA
Manual tray (width only) detection size
40
40 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the manual paper feed
tray paper size detector and the related circuit. (The op-
eration of the manual paper feed tray paper size detec-
tor can be monitored with the LCD.)
Section
Paper transport
Item
Operation
Operation/
Procedure
The operations of the sensors and detectors in the
manual paper feed section are displayed.
The active sensors and detectors are highlighted.
MPLS1
Manual tray length detection 1
MPLS2
Manual tray length det3ction 2
MPLD1
Manual feed paper length detection 1
MPLD2
Manual feed paper length detection 2
One of
these is
displayed.

 
 
 
 
 
 
 
 
 
 
A4/A3
Manual tray (width only) detection size
11x
Manual tray (width only) detection size
B5/B4
Manual tray (width only) detection size
8.5x
Manual tray (width only) detection size
A5/A4R
Manual tray (width only) detection size
B5R
Manual tray (width only) detection size
POSTCARD Manual tray (width only) detection size
EXTRA
Manual tray (width only) detection size
40 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the manual paper feed tray paper width
detector detection level.
Section
Paper transport
Item
Operation
Operation/
Procedure
1. Open the manual paper feed guide at maximum.
2. Press the [MAX POSITION] key.
3. Press the [EXECUTE] key.
The[EXECUTE] key is highlighted then it returns to the normal
display.
The manual paper feed guide max. width position detection
level is recognized.
4. Open the manual paper feed guide at minimum.
5. Press the [MIN POSITION] key.
6. Press the [EXECUTE] key.
The key is highlighted then it returns to the normal display.
The manual paper feed guide min. position detection level is
recognized.
If the above operation is not performed properly, the ERROR dis-
play is highlighted.
If performed properly, the above data is stored and the COM-
PLETE is highlighted.
41
41 - 1
Purpose
Operation test/check/Operation data output/Check (Dis-
play/Print)
Function
(Purpose)
Used to check the operation of the document size sen-
sor and the related circuit. (The operation of the docu-
ment size sensor can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The operations of the sensors and detectors in the
document size detection section are displayed.
The active sensors and detectors are highlighted.
OCSW Document
cover state
Normal display:
Open 
Highlighted display:
Close
PD*
Document
sensor
Normal display:
Document empty
Highlighted display:
Document exist
AR-505
10/8/1999
7 – 30
41 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjsut the document size sensor detection
level.
Section
Others
Item
Operation
Operation/
Procedure
1. Open the original table, and press the [EXECUTE]
key with no original on the original table. The sensor
level setting with no original on the table is per-
formed. 
(Normal case) The COMPLETE display is highlighted (for 1
sec), then it returns to the normal display.
(Abnormal case) The INCOMPLETE display and the
abnormal sensor name are highlighted. 
2. Set an A3 paper (11" x 17") and press the [EXECUTE] key.
The sensor level setting with original is performed.
(Normal case) The COMPLETE display is highlighted (for 1
sec), then it returns to the normal display. The
"NO ORIGINAL" display turns to "A3
ORIGINAL".
(Abnormal case) The INCOMPLETE display and the
abnormal sensor names are highlighted.
41 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size sen-
sor and the related circuit. (The document size sensor
output level can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor is displayed
in real time.
OCSW
Document cover state
PD*
Document sensor
*
The value in [ ] shown at the right of each sensor name is the
threshold value.
43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with [
­
], [
¯
] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in proce-
dure 2.
Used to set the fusing temperature in the normal mode and in
the power save mode.
INSIDE NORMAL:
The control temperature in the normal
mode and when the center lamp is
heated. (190) (AR-501/505 (200))
OUTSIDE NORMAL: The control temperature in the power
save mode (pre-heat mode) and the side
lamps are heated. (190) (AR-501/505
(200))
INSIDE PREHEAT:
The control temperature in the manual
copy mode when the center lamp is
heated. (*1)
OUTSIDE PREHEAT: The control temperature in the manual
copy mode when the side lamps are
heated. (*2)
INSIDE MFT:
The control temperature in the manual
copy mode when the center lamp is
heated. (200)
OUTSIDE MFT:
The control temperature in the manual
copy mode when the side lamps are
heated. (200)
( ): 
Default
Destination
Pre-heat mode fusing temperature set value
MODEL
AR-230/280/285 
series
AR-2X1/2X6/3X1
/250 series
AR-330/335
series
AR-3X6 series
AR-4XX series
AR-501/505
U.S.A. (Inch)
125
130
140
Canada (Inch)
125
130
140
Other (Inch)
125
130
140
Japan
130
130
140
Other (AB)
125
130
140
Europe (AB)
110
130
140
U.K. (AB)
110
130
140
Aus. (AB)
110
130
140
AR-505
7 – 31
8/6/1999
Page of 51
Display