DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

CODE: 00ZAR505//A1E
Digital Copier
AR-250
AR-280/281
AR-285/286
AR-335/336
AR-405
MODEL
AR-501/505
(AR-280/281)
(AR-285/286/335/336)
(AR-405)
(AR-250)
(AR-501/505)
[ 1 ] GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-1
[ 2 ] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1
[ 3 ] CONSUMABLE PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-1
[ 4 ] INSTALLATION AND SETUP . . . . . . . . . . . . . . . . . . . . . . . . . .  4-1
[ 5 ] EXTERNAL VIEW AND INTERNAL STRUCTURE. . . . . . . . . .  5-1
[ 6 ] SETTING AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . .  6-1
[ 7 ] SIMULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7-1
[ 8 ] DISASSEMBLY, ASSEMBLY, MAINTENANCE . . . . . . . . . . . .  8-1
[ 9 ] TROUBLE CODE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9-1
[10] OPERATIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . .  10-1
CONTENTS
AR-505
[7] SIMULATION
(Diagnostics, setting, adjustment value
input, data display)
1. Outline and purpose
There are following, simulation functions to check the machine
operations, troubleshoot, find causes, make various settings, improve
adjustment work speeds and serviceability. 
1) Various adjustments
2) Specification and function setting
3) Trouble cancel
4) Operation check
5) Counters check, setting, clear
6) Machine operation conditions (operation history) data check, clear
7) Transmission of various data (adjustment, setting, operations,
counter, etc.)
The operating procedures and displays slightly differ from the form of
the machine operation panel.
The typical forms are as follows:
1) Code system: Values input and mode selection are made with the
10-key pad and various function keys. 
2) Switch system: Simulation mode selection is made by
combination of switch setting. 
3) Values and mode selection is made with various function keys. As
a special one, a jumper wire is used to connect the check points
on the PWB to select the desired mode. 
2. Code system simulation 
A. Operating procedures and operations
*
Entering the simulation mode
1) Program (P) key 
®
 Interrupt key 
®
 Clear key 
®
 Interrupt key
(The machine enters the standby mode for the simulation main
code.)
2) Enter the main code with 10-key pad. 
®
 Press START key.
3) Enter the sub code of with 10-keypad. 
®
 Press START key.
4) Select the mode and the item with the 1-key pad and the function
key. 
5) The machine enters the selected mode.
To start the simulation, press the START key or the function key.
To cancel the current simulation mode and to change the main
code and the sub code, press the interrupt key. 
*
The simulation mode is canceled and the machine returns to the
normal operation mode. 
1) Press the all clear key. 
SIM 46-12, 13, 14, 15, 16, SIM66 and SIM68 are provided only for Japan
models (FAX mode/ASK/IrDA).
AR-505
7 – 1
8/6/1999
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
Standby for entry of SIM
sub code
Enter SIM sub code with
the 10-key.
Press the START button.
Press the START button.
The display is made according
to the selected mode and the item.
START (Normal mode)
Press the Program (P) key.
Press the interrupt key.
Press the clear key.
Press the interrupt key.
Standby for entry of
SIM code.
Enter the main code of
SIM with the 10-key.
The main code of SIM
is displayed.
Press the START button.
Is there a sub code ?
Select the mode and the
item with the 10-key and
the function key.
Operation check ?
Operating conditions
check ?
Data clear ?
Adjustments
or setting (counter data
change) ?
Do you
want to change the
content ?
Enter the new setting and
adjustment values.
Press the interrupt key.
Press the START button.
Operation is made according
to the selected mode and item.
Press the START button.
The display is made according to
the selected mode and the item.
Press the START button.
Press the START button.
Is it the same
simulation ?
Press the interrupt key.
Do you want
to perform another
simulation ?
Do you
want to end the
simulation ?
The changed content
is stored.
The simulation mode
is canceled.
Press the clear all key.
Operation is made according
to the selected mode and the item.
(Other modes)
The selected mode and
the item are cleared.
AR-505
8/6/1999
7 – 2
[Descriptive Conventions]
For the sake of keeping the use of information common among several models, this manual uses the following conventions:
AR-5XX:
Refers to model AR-501/505,
AR-4XX:
Refers to model AR-405,
AR-2X1/3X1/4XX/250/XX6: AR-281/286/405/250/336,
AR-2XX, 3XX:
Refers to model AR-280/285/335 for this issue.
*
The "X" stands for any numeral 0 to 9.
B. List
Code
Function (Purpose)
Main
Sub
1
1
Used to check the operation of the scanner unit and its
control circuit.
2
Used to check the operation of sensors and detectors in the
scanner section and the related circuit.
2
1
Used to check the operation of the SPF/ADF/RSPF/RADF
unit and its control circuit.
2
Used to check the operation of sensors and detectors in the
SPF/ADF/RSPF/RADF units and the related circuit.
3
Used to check the operation of the loads in the
SPF/ADF/RSPF/RADF units and the control circuits.
3
2
Used to check the operation of sensors and detectors in the
sorter and the related circuit.
3
Used to check the operation of the loads in the sorter and the
control circuit.
6
Used to adjust the finisher stacking capability. (Used to adjust
the stop position of the finisher paper width direction
alignment plate (jogger). This adjustment is made by
changing the width direction alignment plate home position by
the software.) 
4
2
Used to check the operation of sensors and detectors in the
paper feed section (desk feed, large capacity tray) and the
related circuit.
3
Used to check the operation of the loads in the paper feed
section (desk paper feed, large capacity tray) and the control
circuits.
5
1
Used to check the operation of the display, LCD in the
operation panel, and control circuit.
2
Used to check the operation of the heater lamp and the
control circuit.
3
Used to check the oepration of the copy lamp and the control
circuit.
4
Used to check the operation of the discharge lamp and the
control circuit.
6
Used to check the operation of the separation lamp and its
control circuit. (AR-501/505 only)
6
1
Used to check the operation of the loads (clutches and
solenoids) in the paper transport system and the control
circuit.
2
Used to check the operation of each fan motor and its control
circuit.
7
1
Used to set the aging operation conditions.
6
Used to set the cycle of intermittent aging.
8
Used to set YES/NO of display of the warmup time.
8
1
Used to check and adjust the operation of the developing bias
voltage in each print mode and the control circuit. (for OPC
drum type B)
2
Used to check and adjust the operation of the main charger
grid voltage in each print mode and the control circuit. (for
OPC drum type B)
6
Used to check and adjust the transfer charger current and the
control circuit.
7
Used to check and adjust the operation of the separation
charger voltage and its control circuit.
9
1
Used to check the operation of the loads (clutches and
solenoids) in the duplex section and the control circuit.
2
Used to check the operation of sensors and detectors in the
duplex section and the control circuit.
4
Used to check the operation of the duplex unit alignment plate
and its control circuit.
Code
Function (Purpose)
Main
Sub
10
0
Used to check the operation of the toner motor and its control
circuit. 
(Note) 
Do not execute this simulation with toner in the toner hopper.
If executed, excessive toner may enter the developing
section, causing an overtoner trouble.  Be sure to remove the
toner motor from the toner hopper before executing this
simulation.
13
0
Used to cancel the self diag U1 trouble.
14
0
Used to cancel the self diag U1/LOC/U2/PF troubles.
15
0
Used to cancel the self diag U4 - 09/20/21/22 (large capacity
tray) trouble.
16
0
Used to cancel the self diag U2 trouble.
17
0
Used to cancel copy inhibition by the host computer during
the self diag PF.
21
1
Used to set the maintenance cycle.
22
1
Used to check the print out count of each section in each
operation mode. 
(Used to check the maintenance timing.)
2
Used to check the total numbers of misfeed and troubles.
(When the number of misfeed is considerably great, it is
judged as necessary for repair. The misfeed rate is obtained
by dividing this count value with the total counter value.)
3
Used to check the misfeed positions and the number of
misfeed in each position. (If the number of misfeed is
considerably great, it can be judged as necessary for repair.)
(Sections other than  ADF/RADF/SPF sections)
4
Used to check the total trouble (self diag) history.
5
Used to check the ROM version of each unit (section).
6
Used to output the list of the setting and adjustment data
(simulations, FAX soft switch, counters).
7
Used to display the key operator code. (This simulation is
used when the customer forgets the key operator code.)
8
Used to check the number of use of the staple, the ADF,
RADF, SPF, and scanning.
9
Used to check the number of use of each paper feed section.
(the number of prints)
10
Used to check the system configuration (option, internal
hardware).
11
Used to check the use frequency of FAX (send/receive).
(FAX model only)
12
Used to check the misfeed positions and the number of
misfeed at each position. (When the number of misfeed is
considerably great, is can be judged as necessary for repair.)
24
1
Used to clear the misfeed counter, the misfeed history, the
trouble counter, and the trouble history. (The counters are
cleared after completion of maintenance.)
2
Used to clear the number of use (the number of prints) of
each paper feed section.
3
Used to clear the data of the number of use of the staple, the
SPF, ADF, RSPF, RADF and scanning.
4
Used to reset the maintenance counter.
5
Used to reset the developer quantity counter. (The developer
counter of the installed developing unit is reset.)
6
Used to reset the copy counter.
7
Used to clear the OPC drum (membrane decrease)
correction counter. 
(This simulation is executed when the OPC drum is replaced.
8
Used to clear the Zaurus print counter.
AR-505
7 – 3
8/6/1999
Page of 51
Display

Sharp AR-505 (serv.man9) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-505 (serv.man9) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-505 (serv.man9) Copying Equipment. Information contained in Sharp AR-505 (serv.man9) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.