DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

(When RSPF is installed)
SEPARATE (SUNRIS) Post-separation sensor
READ (RDS) Read sensor
SWITCH (SBS) Switch-back sensor
53 - 6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the RSPF width detection level.
(AR-501/505 only)
Section
Image process
Item
Operation
Operation/
Procedure
1. Press "TRY VR (MIN)" key (touch panel) in Fig. 2 to
close the RSPF tray guide to the minimum. Then
Press the EXECUTE key to start the adjustment.
During the adjustment, the EXECUTE key is high-
lighted. When the EXECUTE key is pressed under
this state, the adjustment is interrupted.
When two or more operations are selected, the item which is
displayed at the top is performed and the other items are can-
celed. The canceled items are returned to the normal display.
After completion of the adjustment, the adjustment result is dis-
played with the adjustment item remained highlighted.
(Normal end)
The menu of Fig. 4 is displayed for 3 sec, then the menu of Fig. 5
is displayed to complete the adjustment procedure.
The adjustment result data is displayed with numerical figures.
(Abnormal end)
The menu of Fig. 6 is displayed. IN this case, check the tray guide
position again, and press the EXECUTE key to perform the sensor
adjustment again.
2. Press "TRAY VR (MAX)" key (touch panel) to open the RSPF
tray guide to the maximum.
Then press the EXECUTE key to start the adjustment. During
the adjustment, the EXECUTE key is highlighted. When the
EXECUTE key is pressed under this state, the adjustment is
interrupted.
When two or more operations are selected, the item which is
displayed at the top is performed and the other items are can-
celed. The canceled items are returned to the normal display.
After completion of the adjustment, the adjustment result is dis-
played with the adjustment item remained highlighted.
60
60 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation (read/write) of ICU
(DRAM). (SIMM MEMORY/ONBOARD MEMORY)
Section
ICU
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key to check the read/write
operations.
2. After completion of the read/write operation check, the check
result is displayed with OK or NG.
61
61 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to test the operation of the scanner (exposure)
unit.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key
The scanner unit is started.
2. After completion of check operation, the result is displayed with
OK or NG.
Used to check whether the sync signal (HSYNC/) is normally
outputted or not by operating the laser (exposure) unit (laser
motor rotation, laser emission).
AR-505
10/8/1999
7 – 44
61 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (exposure) laser power (ab-
solute value) in the copy mode.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
(AR-230/280/285/330/335 series)
All must be set to "16."
(AR-2X1/2X6/3X1/3X6 series)
Set all to "7" except for PH256.
(AR-4XX series)
Set all to "5" except for PH256.
(AR-501/505)
All must be set to "5."
61 - 4
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (exposure) laser power (ab-
solute value) in the printer mode. (For Photoconductor
type B)
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
(AR-230/280/285/330/335 series)
Set all the values to the default value 16.
(AR-2X1/2X6/3X1/3X6)
Set all the values to the default value 7.
(AR-4XX/501/505 series)
Set all the values to the default value 5.
62
62 - 1
Purpose
Setting/Data clear
Function
(Purpose)
Used to format the hard disk. (Target models: AR-
250/280/285/335)(Models with the hard disk installed
only)
Section
Memory
Item
Others
Operation/
Procedure
1. Press the [EXECUTE] key.
The display for reconfirmation to clear or not is
shown.
2. Select YES/NO to format.
YES: Formatting is performed.
NO:
Formatting is not performed.
3. Press YES.
Formatting is performed. After completion, the result is shown
with OK or NG.
This procedure is necessary when the hard disk is replaced.
If NG is displayed, it means a hard disk trouble.
AR-505
7 – 45
8/6/1999
62 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation (read/write) of the hard
disk. (Target models: AR-250/280/285/335)(Models
with the hard disk installed only.) (Partial check) 
Section
Memory
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key to start the read/write op-
eration check.
2. After completion of the read/write operation check, the result is
displayed with OK or NG.
If NG is displayed, it means a hard disk trouble.
62 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation (read/write) of the hard
disk.  (Target models: AR-250/280/285/335) (Only the
models with a hard disk) (All area check) 
Section
Memory
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key to start the read/write op-
eration check.
2. After completion of the read/write operation check, the result is
displayed with OK or NG.
If NG is displayed, it means a hard disk trouble.
63
63 - 1
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the result of shading correction. (The
shading correction data are displayed.)
Section
Scanner (Exposure)
Item
Operation
Operation/
Procedure
Used to display the result of latest shading correction.
The displayed page can be shifted with [
­
], [
¯
] keys.
ODD/EVEN OFFSET: Difference between the average detection
level and the max. detection level
BLACK OFFSET:
Dark component (average level)
63 - 7
Purpose
Adjustment
Function
(Purpose)
Used to adjust the white plate scanning start position in
the shading white correction. (AR-501/505 only)
Section
Scanner
Item
Operation
Operation/
Procedure
1. When this simulation is executed, the currently set
value is displayed.
At that time, the set value can be changed with the
10-key.
2. When the OK key is pressed, the currently set value is stored
in the EEPROM.
64
64 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the printer function
(auto print operation). (Print pattern, paper feed mode,
print mode, the number of sheets, and the density can
be set to an arbitrary value.)
Section
Printer
Item
Operation
Operation/
Procedure
1. Select the item with [
­
], [
¯
] keys.
2. Enter the print conditions with the 10-key. (There are
29 kinds of print patterns.)
3. Press the [EXECUTE] Key.
Printing is executed under the condition set with procedure 2.
A:
Self print pattern
-------- 1.ALL 1BY1(V)
B:
Density level
2.ALL 1BY1(H)
C:
Self print number
setting
3.ALL 1BY2(V)
AR-505
8/6/1999
7 – 46
D:
Picture quality mode
4.ALL 1BY2(H)
1: Auto
5.ALL 1BY3(V)
2: Character
6.ALL 1BY3(H)
3: Character/Photo
7.ALL 1BY4(V)
4: Photo
8.ALL 1BY4(H)
E:
Paper feed source
select
9.ALL 1BY5(V)
1: Manual
10.ALL 1BY5(H)
2: Upper cassette
11.ALL 2BY2(V)
3: Lower cassette
12.ALL 2BY2(H)
4: Desk top cassette
13.ALL 2BY3(V)
5: Desk middle cassette
14.ALL 2BY3(H)
6: Desk bottom cassette
15.BLACK *1
7: LCC
16.GRAY SCALE 120/4(V) *3 *4
F:
Duplex print select
17.GRAY SCALE 120/4(H) *2 *4
0: Single
18.GRAY SCALE 250/8(V) *2
1: Duplex
19.GRAY SCALE 250/8(H) *2
20.DOT PATTERN 250/2(V) *1
21.GRAY SCALE 250/2(H) *3 *4
22.SQUARE
23.SLANT 45
24.SLANT 26.6
25.SLANT 63.4
26.ID/BG
27.DOT PATTERN 12.5%
28.DOT PATTERN 25%
29.DOT PATTERN 50%
30.SMOOTHING CHECK
PATTERN
*1: In AR-2X1/3X1/4XX/250/XX6 series, only Japan specification
model allows density change. 
*2: In AR-2X1/3X1/4XX/250/XX6 series, only Japan specification
model works. 
*3: AR-2X1/3X1/4XX/250/XX6 series cannot work.
*4: AR-501/505 cannot work.
65
65 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the touch panel (LCD display) detecting
position.
Section
Operation (Display/Operation key)
Operation/
Procedure
Touch the four cross marks.
The coordinates at the pressed point are set.
When the coordinates are properly set, the display turns to gray
and returns to the simulation sub code entry screen.
In case of an abnormality, it returns to the input display.
65 - 2
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the result of the touch panel (LCD dis-
play) detecting position adjustment. (The coordinates
are displayed.)
Section
Operation (Display/Operation key)
Operation/
Procedure
When the touch panel is pressed, the AD value in each
of X and Y directions at that point and the coordinate
values are displayed in ( ) as well as the coordinate val-
ues of each point.
It is based on the coordinates set with SIM 65-1.
67
67 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the printer PWB memory operation
(read/write). (When replacing the PWB with a new one,
this check must be performed.)
Section
Printer
Item
Data
Operation/
Procedure
1. When SIM 67-1 menu is displayed, the operation
check of all memory (DRAM, SIMM1, SIMM2) of the
printer section is started.
2. For the RAM the operation check of which is started, "--------"
display is changed to "CHECKING." When checking is com-
pleted, the check result is displayed with "OK" or "NG."
When SIMM is inserted, the memory capacity is also displayed
as "OK(16MB)."
AR-505
7 – 47
8/6/1999
Page of 51
Display