DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

Enter the code number with the 10-key pad and press the [OK]
key.
Detection size when 8.5" x 13" document/paper is used
Unit
Destination
Set value
0
(Default)
(Invalid)
1 (Valid)
Document AR-SP1
All
destinations
8.5" x 14" 8.5" x 13" *1
AR-AF1
AR-RF1
Japan
A4R
A4R
*5
EX AB
series
(SLK/SEEG)
A4R
A4R
*5
EX AB
series
(SCA/
Others)
A4R
8.5" x 13" *3
Inch series
(SEC/SECL)
8.5" x 14" 8.5" x 14" *5
Inch series
(Others)
8.5" x 14" 8.5" x 13" *1
Document
table
Japan/EX
AB series
B4
8.5" x 13" *2
Inch series
8.5" x 14" 8.5" x 13" *1
Paper
Main
body
Manual
feed
tray
All
destinations
8.5" x 14" 8.5" x 13" *4
Paper
feed
cassette
All
destinations
        —      *6
AR-DE1/DE2
All
destinations
AR-LC1
All
destinations
*1: A document of 8.5" x 14" is detected as 8.5" x 13".
*2: A document of B4 is detected as 8.5" x 13".
*3: A document of A4R is detected as 8.5" x 13".
*4: A document of 8.5" x 14" is detected as 8.5" x 13".
*5: Applicable by replacing the document set tray of the AR-
AF1/RF1.
*6: Setting is available with the key operator program (P40).
Value
Display
Paper
1
Characters
HEAVY PAPER
PLAIN PAPER
2
Weight in g.
106 - 200 g/m
2
56 - 105 g/m
2
3
Weight in lbs.
28+ - 55 lbs
15 - 28 lbs
26 - 3
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the auditor. Setting
must be made depending on the use condition of the
auditor.
Section
Auditor
Item
Specifications
Operation/
Procedure
Enter the code number corresponding to the auditor
specification mode with the 10-key pad and press the
[OK] key.
Set value 
Specification mode 
1
Built-in auditor mode (Default)
2
Coin vendor 
3
Others 
26 - 5
Purpose
Setting
Function
(Purpose)
Used to set the count mode of the total counter and the
maintenance counter.
Item
Specifications
Counter
Operation/
Procedure
Used to set the single count-up or double count-up for
the total counter, the maintenance counter, and the de-
veloper counter when printing is performed with A3, 11
x 17" paper,
1. Select the kind of the counter with [
] and [
] key.
A
Total
B
Maintenance
C
Developer
2. Enter "1" or "2" with the 10-key pad and press the [OK] key.
1: Single count
2:  Double count
Default: 2
26 - 6
Purpose
Setting
Function
(Purpose)
Used to set the specifications depending on the desti-
nation.
Item
Specifications the
destination
Destination
Operation/
Procedure
Select the destination referring to the table below.
U.S.A.
United States of America
Canada
Canada
Inch
Inch series, other destinations
Japan
Japan
AB_B
AB series (B5 detection) other destinations
Europe
Europe
U.K.
United Kingdom
Aus.
Austrailia
AB_A
AB series (A5 detection) other destinations
When the destination setting is changed, the following specifica-
tion is changed.
(Toner save mode setup specification) (Paper specification)
AR-505
10/8/1999
7 – 24
26 - 15
Purpose
Setting
Function
(Purpose)
Used to set the fusing operation mode (paper curl cor-
responding mode).
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
Due to the paper type (paper property), paper may be
curled in the fusing section and cause a paper jam. To
prevent against this, the fusing condition is changed.
Enter the code number corresponding to the fusing condition and
press the [OK] key. 
Set value 
Remedy mode
Fusing condition
0
Normal operation 
(Default)
1
Remedy mode 1
a. Racing until the specified
fusing temperature is
reached.
2
Remedy mode 1
a. Racing is performed until
the specified fusing
temperature is reached.
b. Copy mode is duplex mode
or sort.
Group mode 
Previous rotation is made
for 5 sec before starting
copying.
26 - 18
Purpose
Setting
Function
(Purpose)
Used to set VALID/INVALID of toner save operation.
(This simulation is valid only in the Japan and UK ver-
sions. (It depends on SIM 26-6 (Destination setting).
For the other destinations, the same setting can be
executed with the user program.)
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
Enter the code number corresponding to the condition
(the toner save YES/NO) with the 10-key and press the
[OK] key.
Set value 
Toner save 
0
YES 
1
NO (Default)
26 - 22
Purpose
Setting
Function
(Purpose)
Used to set the specification (language display) for the
destination. (Target models: AR-280/285/335) (Exclud-
ing the Japan models.)
Item
Specifications
Operation/
Procedure
Select the language to be used according to the table
below. 
Display Language 
ENG.(US)
English(US)
ENG.(UK)
English(UK)
FRENCH
French 
SPANISH
Spanish 
GERMAN
German 
26 - 30
Purpose
Setting
Function
(Purpose)
Used to set the CE mark conforming operation mode.
(For flickers when driving the fusing heater lamp.)
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
Enter the number corresponding to the operation mode
with the 10-key and press the [OK] key.
Set value 
Content 
0
CE mark control inhibit 
1
CE mark control allowed (Default)
0:  Normal operation heater lamp slow up control
1: CE mark standard complying operation (Heater lamp slow up
control) (Europe)
26 - 35
Purpose
Setting
Function
(Purpose)
Used to set whether the trouble history display of SIM
22-4 is displayed as one trouble or as the number of
continuous troubles when two or more troubles of a
same kind occured.
Item
Specifications
AR-505
7 – 25
10/8/1999
Operation/
Procedure
Used to set whether the trouble history display by SIM
22-4 is displayed as one trouble or as the accumulated
number of continuous troubles when two or more trou-
bles of same kind occur continuously.
Select the number corresponding to the display mode with the 10-
key and press the [OK] key.
1: The trouble history display by SIM 22-4 is displayed as it is
when two or more troubles occur continuously.
0: The trouble history display by SIM 22-4 is displayed as one
trouble when two or more troubles occur continuously.
Default: 0
26 - 36
Purpose
Setting
Function
(Purpose)
Used to set the ICU fan operating temperature. (Opera-
tion in pre-heat mode.) (Excluding Japan models.)
Section
ICU
Item
Operation
Operation/
Procedure
Used to set the threshold value of the ambient tem-
perature for turning ON the ICU fan motor in the pre-
heat mode.
Set range : 0~33[°C]
Default : 30[°C] (30)
Enter the operating temperature with the 10-key pad
and press the [OK] key.
26 - 40
Purpose
Setting
Function
(Purpose)
Polygon motor stop mode setup (AR-501/505)
Used to set the stop time of the polygon motor after
leaving in ready state and to set Enable/Disable of the
setting. (Other models)
Item
Specifications
Operation/
Procedure
(AR-501/505)
When this simulation is executed, the current set value
is displayed.
At that time, the set value can be changed with the 10-key.
When the OK key is pressed, the currently set value is stored in
the EEPROM.
Default: 0
0
Normal mode
Control according to the setup in the
silent mode by the user setup.
1
Silent mode
After completion of a job, the polygon
motor is stopped in the time set in the
silent mode of the user setup.
(Other models)
A
1. Used to set the time (minute) to stop the polygon motor with
the 10-key.
(Regardless of setting in B, the time can be freely set.)
2. Press the OK key to store the set time.
3. Press the CA key to reset. Only when B is set to "1: YES", the
polygon motor is stopped in the set time.
Set range: 1-30 min
Default: 30 min
B Used to set YES/NO of the setup of A.
Default: 0 (NO)
Set value
Content
0
NO (The currently set operation is performed.)  
SP/FP does not stop.
40 NEW Stops in the default time (30 min).
1
Stops in the set value of A.
26 - 41
Purpose
Setting
Function
(Purpose)
Used to enable/disable the auto magnification ratio se-
lect (AMS) function in the pamphlet copy mode.
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
This simulation is used to enable or disable the auto-
matic magnification ratio selection (AMS) in the pam-
phlet mode.
Set value
Set content
0
Automatic magnification ratio selection (AMS) is
enabled. 
1
Automatic magnification ratio selection (AMS) is
disabled. 
26 - 44
Purpose
Setting
Function
(Purpose)
Used to set the model of the unit which is connected to
the SCSI I/F of ICU PWB.
Section
ICU
Item
Specifications
Interface/Communication
AR-505
10/8/1999
7 – 26
Operation/
Procedure
A is at the left of B when viewed from the rear side.
0:  No connection
1:  Printer controller
3:  External printer controller (Not used)
4:  Scanner controller (Not used)
8:  Tandem connection (Initiator)
10: Tandem connection (Target)
One SCSI channel available (Japan only) 
Two SCSI channels available
(AR-501/505)
(Other models)
26 - 46
Purpose
Setting
Function
(Purpose)
Used to set the image direction or not regardless of
modes when the finisher/sorter is installed.
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
This simulation is used to set the image direction or not
regardless of modes when the finisher/sorter is in-
stalled. (Other models than AR-501/505)
Set value
Set content
0
Not set. (The image direction is changed in the
staple mode of FN1
.)
1
Set. (The image direction is not changed
regardless of presence of the staple.)
Default: 0
26 - 50
Purpose
Setting
Function
(Purpose)
Used to set YES/NO of black/white reversion is al-
lowed.
Item
Specifications
Operation/
Procedure
When this simulation is executed, the current set value
is displayed.
At that time, the set value can be changed with the 10-
key.
When the OK key is pressed, the currently set value is stored in
the EEPROM.
Default: 1 (YES) (Black/white reversion is allowed.)
0
NO: Black/white reversion is inhibited.
1
YES: Black/white reversion is allowd.
26 - 52
Function
(Purpose)
Used to set whether white paper discharge count up is
performed or not.
("White paper" means insertion paper in the OHP inser-
tion paper mode (without copy), cover paper in the
cover paper insertion mode (without copy)/back cover,
and white paper in the duplex exit mode (CA etc.).)
Operation/
Procedure
When this simulation is executed, the current set value
is displayed.
Under this state, the set value can be changed with the
10-key.
When the OK key is pressed, the currently set value is stored in
the EEPROM. 
Set value
Content
A
0
White paper count up is not performed.
1
White paper count up is performed.
Destination Default
U.K./Europe/Aus.
0 (Count up is not performed.)
Others
1 (Count up is performed.)
When set to 0 (count up is nor performed), the following counters
do not count up. 
COPIES counter
Total counter
Maintenance counter
Developer counter
Department management counter
The signal (PNC) for the external auditor (mechanism counter)
is not outputted. 
AR-505
7 – 27
10/8/1999
Page of 51
Display