DOWNLOAD Sharp AR-505 (serv.man9) Service Manual ↓ Size: 1.06 MB | Pages: 51 in PDF or view online for FREE

Model
AR-505 (serv.man9)
Pages
51
Size
1.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR505 Service Manual-Simulation
File
ar-505-sm9.pdf
Date

Sharp AR-505 (serv.man9) Service Manual ▷ View online

Note
Be sure to set to the default value. If not, a trouble may
occur.
43 - 3
Function
(Purpose)
Used to adjust the fusing motor speed. (AR-501/505
only)
Operation/
Procedure
When this simulation is executed, the current set value
is displayed. Under this state, the set value can be
changed by pressing the 10-key. When [OK] key is
pressed, the set value is stored in the EEPROM.
Adjustment value
70
100
130
Speed
97%
100%
103%
An increase in the adjustment value by 1 corresponds to an in-
crease in the speed by 0.1%
A decrease in the adjustment value by 1 corresponds to a de-
crease in the speed by 0.1%
43 - 8
Function
(Purpose)
Used to set the time to rotate the fusing motor after
reaching the set temperature in warming up. (AR-
501/505 only)
Operation/
Procedure
When this simulation is executed, the current set value
is displayed. Under this state, the set value can be
changed by pressing the 10-key. When [OK] key is
pressed, the set value is stored in the EEPROM.
Set range: 10 – 120 sec
Default:
Varies according to the destination setup (SIM 26-6).
Japan: 30 sec
EX Japan: Varies according to the destination.
44
44 - 1
Purpose
Setting
Function
(Purpose)
Used to set whether the correction functions of the im-
age forming (process) section are valid or not.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Operation/
Procedure
Enter the code number corresponding to each correc-
tion operation with the 10-key and press the OK key.
To enable all the correction functions, set to 3.
(Note) The default setting must be 3.
Set value
Developing bias voltage
correction limit
OPC drum sensitivity
correction
0
Disable
Disable
1
Disable
Enable
2
Enable
Disable
3
Enable
Enable
Note
(Note) It must be set to the default 3.
44 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the sensitivity (gain) of the OPC drum
mark sensor and the image density sensor.
Section
Image process
(Photoconductor/Develop
ping/Transfer/Cleaning)
Photo conductor
Item
Operation
Operation/
Procedure
When the [EXECUTE] key is pressed, it is highlighted
and the main motor rotates to start the drum marking
sensor and the image density sensor gain adjustment.
(The adjustment is automatically performed.)
After completion of the adjustment, the [EXECUTE] key returns to
the normal display and the main motor stops.
At that time, the gain level of each sensor is displayed.
If the adjustment is not completed properly, the ERROR display is
shown.
DMLED:
Drum marking sensor gain adjustment value
PCLED:
Image density sensor gain adjustment value
DRUM:
Kinds of drums
0: Others
1: AR330DR/AR336DR/AR336DM/ARdR23; 10mm
2: AR330DM/ARDR17; 3 x 4 x 3mm
3: AR400DR/AR400DM; 15mm
5: AR500DR/AR500DM/ARDR25; 5mm
As other models except AR-501/505 do not
recognize 5mm marking, "0" is displayed at that
time. 
AR-505
8/6/1999
7 – 32
44 - 4
Purpose
Setting
Function
(Purpose)
Used to set the target image (reference) density level in
the developing bias voltage correction.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Item
Data
Adjust/Setting data
Operation/
Procedure
1. Enter the set value (38) with the 10-key.
2. Press the [OK] key. (The value entered in procedure
1 is set.)
Set value: 36 (AR-501/505), 38 (Other models)
Note
It must be set to 36 for AR-501/505 or 38 for other
models.
44 - 5
Purpose
Setting
Function
(Purpose)
Used to set various parameters (main charger grid volt-
age, laser beam power, correction start developing bias
voltage) in developing bias correction.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Operation/
Procedure
1. Select the parameter mode with [
], [
] keys.
2. Enter the parameter with the 10-key.
3. Press the [OK] key. (The value entered in procedure 2 is set.)
GRID BIAS VOL:
Reference charging voltage level in patch
forming (AR-501/505; 360), other models;
380) (Set value)
DEVE BIAS VOL : Reference developing bias voltage level in
patch forming (210) (Set value)
LASER DUTY:
Laser duty level in patch forming (255)
Note
Be sure to set to the specified value. If not, the print im-
age density may be disturbed.
44 - 9
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the data on the result of the image form-
ing section correction (process correction) (the cor-
rected main charger grid voltage in each print mode,
developing bias voltage, the laser power, etc.)
(This simulation allows to check whether the correction
is executed properly or not.)
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Item
Data
Operation data
(Machine condition)
Operation/
Procedure
Used to display the drum rotating time and the high
voltage output in each copy mode and the laser power
correction power.
(AR-250/280/281/285/286/335/336/405)
DRUM ROTATION:
Drum rotating time (sec)
DEVE RFERENCE ADJUST: Toner concentration correction
amount
DRUM:
Drum identification result
0: Others
1: AR330DR/AR336DR/AR336DM/ARdR23; 10mm
2: AR330DM/ARDR17; 3 x 4 x 3mm
3: AR400DR/AR400DM; 15mm
5: AR500DR/AR500DM/ARDR25; 5mm
As other models except AR-501/505 do not
recognize 5mm marking, "0" is displayed at that
time. 
GR_BS:
Main charger grid voltage level (*1)
DV_BS:
Developing bias voltage level (*1)
(Display) *1 : Sim 8-1, 8-2 Set voltage/actual output
voltage (including corrected amount)
LD_AD:
Laser power correction power display (mW)
AUTO:
Auto mode
CHARA:
Character mode
CHARA_P: Character/photo mode
PHOTO:
Photo mode
PRT:
Printer mode
FAX:
Fax mode (Japan only)
(AR-501/505)
DRUM ROTATION:
Drum rotating time (sec)
DEVE MIXING TIME:
Developer rotating time (sec)
DEVE RFERENCE ADJUST A: Toner concentration correction
amount
DEVE RFERENCE ADJUST B: Toner concentration correction
amount
DRUM:
Drum identification result
0: Others
1: AR330DR/AR336DR/AR336DM/ARdR23; 10mm
2: AR330DM/ARDR17; 3 x 4 x 3mm
3: AR400DR/AR400DM; 15mm
5: AR500DR/AR500DM/ARDR25; 5mm
As other models except AR-501/505 do not
recognize 5mm marking, "0" is displayed at that
time.
GR_BS:
Main charger grid voltage level (*1)
DV_BS:
Developing bias voltage level (*1)
(Display) *1 : Sim 8-1, 8-2 Set voltage/actual output
voltage (including corrected amount)
AR-505
7 – 33
8/6/1999
LD_AD:
Laser power correction power display (mW)
AUTO:
Auto mode
CHARA:
Character mode
CHARA_P: Character/photo mode
PHOTO:
Photo mode
PRT:
Printer mode
FAX:
Fax mode (Japan only)
44 - 12
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the toner image patch density date in
correction operation of the image forming section. (This
simulation allows to check whether the correction is
executed properly or not. )
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Item
Data
Operation data
(Machine condition)
Operation/
Procedure
The latest developing bias correction data is displayed.
The sensor detection level (density) in the toner image
patch section/OPC drum base during the developing
bias corection is displayed.
DMLED:
Drum marking sensor gain adjustment level
PCLED:
Image density sensor gain adjustment level
DV_BS:
The developing bias voltage level when forming
PT2/BS2 of ID (1)
PT1/BS1:
No. 1 toner image patch section/Drum base sensor
detection level
PT2/BS2:
No. 2 toner image patch section/Drum base sensor
detection level
PT3/BS3:
No. 3 toner image patch section/Drum base sensor
detection level
ID (n) : Sequence number of correction operation
44 - 15
Purpose
Setting
Function
(Purpose)
Used to set the correction values of various parameters
(maincharger grid voltage, laser beam power, develop-
ing bias voltage) in the image forming operation and
image forming section correction for OPC drum type A.
(AR-250/280/281/285/286/335/336/405 only)
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Operation/
Procedure
Used to set various parameters of image forming op-
eration and image forming section correction operation
for drum type A.
1. Select the correction item with [
­
], [
¯
] keys.
2. Enter the set value with the 10-key
3. Press the [OK] key. (The value entered in procedure 2 is set.)
DV BIAS:
Developing bias base voltage (Equivalent
to SIM 8-1 for Drum type B.) (500)
GIRD BIAS:
Main charger grid voltage (Equivalent to
SIM 8-2 for drum type B.) (475)
LD POWER:
Laser power (Equivalent to SIM 61-2 for
drum type B.) For
AR-2X1/3X1/4XX/250/XX6 series, set to
"10" (default). For AR-230/250/285/330/335
series, set to "16."
PROCON DB:
Base developing bias voltage in toner
image patch forming (in developing bias
correction) (Equivalent to SIM 44-5B) (500)
(Correction value to SIM 44-5B)
PROCON GB:
Base main charger grid voltage (Equivalent
to SIM 44-5A in drum type B) (500)
(Correction value to SIM 44-5A)
PROCON TARGET: Target image (reference) density level in
developing bias voltage correction
(Equivalent to SIM 44-4 4 in drum type B)
(58)
Be sure to set to the specified value.
Note
Be sure to set to the specified value. If not, the print im-
age density may be disturbed.
46
46 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density in the copy mode (bi-
nary/multi-value  - auto, character and photo, photo
mode). 
(The overall print density in each mode (all of the speci-
fied density set for each density level (display value))
can be adjusted in each mode.)
Item
Picture quality
Density
Operation/
Procedure
1. Select the print mode with [
­
], [
¯
] keys.
(The set value is highlighted.)
2. Enter the adjustment value with the 10-key.
AR-505
8/6/1999
7 – 34
3. Press the [OK] key or the PRINT button.
The value entered in procedure 2 is set.
When the PRINT key is pressed, copying is performed.
(Note)
When a set value (density adjustment value in density
level 3) in the left column of the table below is changed
with this simulation, the set value (the overall density
level set value) in the right column is changed
accordingly.
The parameters of the right and the left simulations and
their adjustment items are the adjustment values in the
same print mode.
The result of adjustment by the simulation executed at
the last is reflected in actual printing.
The print density is normally adjusted by SIM 46-2.
To customize the print density for the density level
display value according to the user’s request, use the
simulation in the right column. (Excluding auto mode)
(AR-230/280/285/330/335 series)
Binary mode
Set with SIM 46-2.
Parameter to be changed
Linked simulation data
AE3.0 (AE)
CH3.0 (Character)
Sim 46-9
MIX3.0 (Character/Photo)
Sim 46-10
PH3.0 
(Photo) Sim 
46-11
Default: 100
(AR-2X1/3X1/4XX/250/XX6 series)
Set with SIM 46-2.
Parameter to be changed
Linked simulation data
A
AE3.0 (AE)
B
CH3.0 (Character)
Sim 46-9
C
MIX3.0 (Character/Photo)
Sim 46-10
D
PH3.0 (2) 
Sim 46-11 (Photo error
diffusion)
E
PH3.0 (256) 
Sim 46-7 (Photo multi
value dither) (Japan only)
For EX, the above value E is disabled.
(AR-501/505)
Set with SIM 46-2.
Parameter to be changed
Linked simulation data
A
AE3.0 (AE)
B
CH3.0 (Character)
Sim 46-9
C
MIX3.0 (Character/Photo)
Sim 46-10
D
PH3.0 (2) 
Sim 46-11 (Photo error
diffusion)
46 - 3
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density in the copy mode (multi
value-auto, character and photo, photo mode). 
(The overall print density in each mode (all of the speci-
fied density set for each density level (display value))
can be adjusted in each mode.)
(AR-250/280/285/330/335 only) (Japan only)
Item
Picture quality
Density
Operation/
Procedure
1. Select the print mode with [
], [
] key.
(The set value is highlighted.)
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key or the PRINT button. (The value entered in
procedure 2 is set.) When the PRINT button is pressed, copy-
ing is performed.
(Note)
When a set value (density adjustment value in density
level 3) in the left column of the table below is changed
with this simulation, the set value (the overall density
level set value) in the right column is changed
accordingly. 
The parameters of the right and the left simulations and
their adjustment items are the adjustment values in the
same print mode.
The parameters of the right and the left simulations and
their adjustment items are the adjustment values in the
same print mode. The result of adjustment by the
simulation executed at the last is reflected in actual
printing.
The print density is normally adjusted by SIM 46-2.
To customize the print density for the density level
display value according to the user’s request, use the
simulation in the right column. (Excluding auto mode/SIM
46-4.)
(Multi value mode)
Sim46-3 Parameter
set/changed by SM 46-3
Linked simulation data
AE3.0 (AE)
CH3.0(Character) Sim46-5
MIX3.0(Character/photo)
Sim46-6
PH3.0(Photo)
Sim46-7
Default: 100
AR-505
7 – 35
8/6/1999
Page of 51
Display