DOWNLOAD Sharp AR-235 (serv.man9) Service Manual ↓ Size: 755.35 KB | Pages: 58 in PDF or view online for FREE

Model
AR-235 (serv.man9)
Pages
58
Size
755.35 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Adjustments, setting Simulation Trouble code list
File
ar-235-sm9.pdf
Date

Sharp AR-235 (serv.man9) Service Manual ▷ View online

AR-235/275 SIMULATION - 12
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore,  the  set  value  entered  must  be  an  even  number.  If  an  odd
number  is  entered  the  entered  odd  number  +  1  is  displayed  after
pressing [OK] key.
Operation/procedure (Pattern 4)
After  selecting  the  mode,  enter  the  adjustment  value  and  press  the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
*1. The  negative  value  of  the  set  value  corresponds  to  the  grid  high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure (Pattern 4)
After  selecting  the  mode,  enter  the  adjustment  value  and  press  the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
*1. The  negative  value  of  the  set  value  corresponds  to  the  grid  high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure (Pattern 3)
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
Display items
Content
Installation 
range
Default
1:DENS1(600)
Density 1 (600dpi)
200-550
400 (–400V)
2:DENS2(600)
Density 2 (600dpi)
450 (–450V)
3:DENS3(600)
Density 3 (600dpi)
450 (–450V)
4:DENS4(600)
Density 4 (600dpi)
450 (–450V)
5:DENS5(600)
Density 5 (600dpi)
500 (–500V)
6:TS(600)
Toner save (600dpi)
350 (–350V)
7:DENS1(1200)
Density 1 (1200dpi)
300 (–300V)
8:DENS2(1200)
Density 2 (1200dpi)
350 (–350V)
9:DENS3(1200)
Density 3 (1200dpi)
376 (–376V)
10:DENS4(1200)
Density 4 (1200dpi)
426 (–426V)
11:DENS5(1200)
Density 5 (1200dpi)
500 (–500V)
8-11
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage (high mode) in each printer mode 
and the control circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Photo conductor
(Initial screen)
(Input/Selection screen) (Executing screen)
Display items
Content
Installation 
range
Default
1:DENS1(600)
Density 1 (600dpi)
1-8
5 (–580V)
2:DENS2(600)
Density 2 (600dpi)
5 (–580V)
3:DENS3(600)
Density 3 (600dpi)
5 (–580V)
4:DENS4(600)
Density 4 (600dpi)
5 (–580V)
5:DENS5(600)
Density 5 (600dpi)
7 (–630V)
6:TS(600)
Toner save (600dpi)
3 (–530V)
7:DENS1(1200)
Density 1 (1200dpi)
1 (–480V)
8:DENS2(1200)
Density 2 (1200dpi)
3 (–530V)
9:DENS3(1200)
Density 3 (1200dpi)
4 (–555V)
10:DENS4(1200)
Density 4 (1200dpi)
5 (–580V)
11:DENS5(1200)
Density 5 (1200dpi)
7 (–630V)
NO.
Set value
Grid High 
Grid Low
480
–480V
–350V
505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
605
–605V
–475V
630
–630V
–500V
655 
–655V
–525V
Sim8-11 MHV(H) PRT
1:DENS1(600)      3
2:DENS2(600)      5
3:DENS3(600)      5
1/4
Sim8-11 MHV(H) PRT
5:DENS5(600)      7
EXEC [  1-  8]  
  7
Sim8-11 MHV(H) PRT
5:DENS5(600)      7
EXEC
 [  1-  8]   
 7
8-12
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in each printer mode 
and the control circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Photo conductor
(Initial screen)
(Input/Selection screen)   (Executing screen)
Display items
Content
Installation 
range
Default
1:DENS1(600)
Density 1 (600dpi)
1-8
5 (–450V)
2:DENS2(600)
Density 2 (600dpi)
5 (–450V)
3:DENS3(600)
Density 3 (600dpi)
5 (–450V)
4:DENS4(600)
Density 4 (600dpi)
5 (–450V)
5:DENS5(600)
Density 5 (600dpi)
7 (–500V)
6:TS(600)
Toner save (600dpi)
3 (–400V)
7:DENS1(1200)
Density 1 (1200dpi)
1 (–350V)
8:DENS2(1200)
Density 2 (1200dpi)
3 (–400V)
9:DENS3(1200)
Density 3 (1200dpi)
4 (–425V)
10:DENS4(1200)
Density 4 (1200dpi)
5 (–450V)
11:DENS5(1200)
Density 5 (1200dpi)
7 (–500V)
NO.
Set value
Grid High 
Grid Low
480
–480V
–350V
505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
605
–605V
–475V
630
–630V
–500V
655 
–655V
–525V
8-13
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the 
developing bias voltage in FAX mode and the control 
circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Developer/Toner hopper
Sim8-12 MHV(L) PRT
1:DENS1(600)      3
2:DENS2(600)      5
3:DENS3(600)      5
1/4
Sim8-12 MHV(L) PRT
5:DENS5(600)      7
EXEC [  1-  8]    
7
Sim8-12 MHV(L) PRT
5:DENS5(600)      7
EXEC
 [  1-  8]    
7
AR-235/275 SIMULATION - 13
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore,  the  set  value  entered  must  be  an  even  number.  If  an  odd
number  is  entered  the  entered  odd  number  +  1  is  displayed  after
pressing [OK] key.
Operation/procedure (Pattern 3)
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec. 
*1. The  negative  value  of  the  set  value  corresponds  to  the  grid  high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure (Pattern 3)
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
*1. The  negative  value  of  the  set  value  corresponds  to  the  grid  high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure (Pattern 9)
Select with the 10-key and operate for 30 seconds.
Operation/procedure (Pattern 1)
Set the rotation speed of the duplex motor.
(Initial screen)
(Executing screen)
Setting range
200-550
Default
426
8-14
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage (high mode) in FAX mode and the 
control circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Photo conductor
(Initial screen)
(Executing screen)
Setting range
1-8
Default
5
NO.
Set value
Grid High 
Grid Low
480
–480V
–350V
505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
605
–605V
–475V
630
–630V
–500V
655 
–655V
–525V
8-15
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in FAX mode and the 
control circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Photo conductor
Sim8-13 DV BIAS FAX
FAX             426
EXEC [200-550]  
4260
Sim8-13 DV BIAS FAX
FAX             426
EXEC
 [200-550]  
426
Sim8-14 MHV(H) FAX
FAX               5
EXEC [  1-  8]  
  5
Sim8-14 MHV(H) FAX
FAX               5
EXEC
 [  1-  8]  
  5
(Initial screen)
(Executing screen)
Setting range
1-8
Default
5
NO.
Set value
Grid High 
Grid Low
480
–480V
–350V
505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
605
–605V
–475V
630
–630V
–500V
655 
–655V
–525V
9
9-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the load 
(motor) in the duplex section and the control circuit.
Section
Duplex
Item
Operation
(Initial screen)
(Executing screen)
1:DMF600
Duplex motor forward rotation (600dpi)
2:DMF1200
Duplex motor forward rotation (1200dpi)
3:DMR600
Duplex motor reverse rotation (600dpi)
4:DMR1200
Duplex motor reverse rotation (1200dpi)
9-4
Purpose
Operation test/check
Function 
(Purpose)
Used to adjust the rotation speed of the duplex motor.
Section
Duplex
Item
Operation
Setting range
1-13
Default
3
Sim8-15 MHV(L) FAX
FAX               5
EXEC [  1-  8]  
  5
Sim8-15 MHV(L) FAX
FAX               5
EXEC
 [  1-  8]   
 5
Sim9-1 MOTOR CHECK
1:DMF600  4:DMR1200
2:DMF1200
3:DMR600
        EXEC      
2
Sim9-1 MOTOR CHECK
1:DMF600  4:DMR1200
2:
DMF1200
3:DMR600
        EXEC      
2
Sim9-4 MOTOR SPEED
MOTOR SPEED       3
     [  1- 13]    
3
AR-235/275 SIMULATION - 14
Operation/procedure (Pattern 2)
Set the switch back time of the duplex motor.
Operation/procedure (Pattern 8)
Press the [OK] key and operate the toner motor for 30 sec.
Pressing  the  [INTERRUPT]  key  interrupts  the  operation,  and  the  dis-
play returns to the main code entry  screen.
Operation/procedure (Pattern 6)
When the [OK] key is pressed, the trouble is canceled.
Operation/procedure (Pattern 6)
When the [OK] key is pressed, the trouble is canceled.
Operation/Procedure (Pattern 6)
When the [OK] key is pressed, the trouble is canceled.
Operation/procedure (Pattern 1)
Enter the adjustment value and press the [OK] key.
9-5
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the switch back time of the duplex 
motor.
(Initial screen)
(Input screen)
Display items
Installation range
Default
1:600dpi
18-76
50
2:1200dpi
50
10
10-0
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of the toner motor and its 
control circuit.
Section
Image process (Photoconductor/Developping/Transfer/
Cleaning)
Developer/Toner hopper
Item
Operation
(Initial screen)
(Executing screen)
14
14-0
Purpose
Clear/Cancel (Trouble etc.)
Function 
(Purpose)
Used to cancel excluding the self-diag U2/PF troubles.
Item
Trouble
Error
(Initial screen)
(Process check screen)
Sim9-5 SW BACK TIME
1:600dpi         50
2:1200dpi        50
                  
1
Sim9-5 SW BACK TIME
1:600dpi         50
     [ 18- 76]   
50
Sim10 TONER MOTOR
PRESS OK KEY   EXEC
Sim10 TONER MOTOR
               
EXEC
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2,PF)
PRESS OK KEY
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2,PF)
ARE YOU SURE?
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function 
(Purpose)
Used to cancel the self-diag U2 trouble.
Item
Trouble
Error
(Initial screen)
(Process check screen)
17
17-0
Purpose
Cancel (Trouble, etc)
Function 
(Purpose)
Used to cancel the self diag "PF" trouble. 
Item
Trouble
Error
(Initial screen)
(Execution check screen)
21
21-1
Purpose
Setting
Function 
(Purpose)
Used to set the maintenance cycle.
Item
SpecificationsCounter
Item
Content
Setting range
Default
0
5K
0-4
3
1
12.5K
2
25K
3
50K
4
FREE
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
PRESS OK KEY
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
ARE YOU SURE?
Sim17 TROUBLE CLEAR
PF TROUBLE CLEAR
PRESS OK KEY
Sim17 TROUBLE CLEAR
PF TROUBLE CLEAR
ARE YOU SURE?
Sim21-1 CYCLE SET.
MAINTE CYCLE      0
(0:5K 1:12.5K
2:25K 3:50K 4:FREE)
     [  0-  4]    
0
AR-235/275 SIMULATION - 15
Operation/procedure
Counter is displayed.
Operation/procedure
Counter data is displayed.
Operation/procedure
The misfeed history is displayed in the sequence of recentness by the
name  of  sensors  and  detectors.  Max.  40  items  of  information  can  be
stored in memory. (The old ones are deleted sequentially.) The trouble
section may be determined by the data.
Operation/procedure
The trouble error codes are displayed in the sequence of the latest one
first. Max. 40 items of information are stored. (Older ones are deleted
in sequence.) The machine condition can be estimated by this data.
Operation/procedure
ROM and CPU data of each section are displayed.
[Display example]
ROM version 1.250 
 [1.25] (upto 2 decimal places)
The display of the protocol monitor and the soft SW follows this display.
22
22-1
Purpose
Adjustment/setting/operation data output/check 
(display/print)
Function 
(Purpose)
Used to check the counter value of each section.
Item
Counter
TOTAL
Total
IMC
IMC counter
MAINTE
Maintenance
DUPLEX
Duplex counter
DEVE
Developer counter
DRUM
Drum counter
OTHERS
The other counters
COPY
Copy counter
FAX SEND
FAX Send counter
PRINTER
Printer counter
FAX RCV
FAX receive counter
22-2
Purpose
Adjustment/setting/operation data output/check 
(display/print)
Function 
(Purpose)
Used to check the total numbers of misfeed and 
troubles. (When the number of misfeed is considerably 
great, it is judged as necessary for repair. The misfeed 
rate is obtained by dividing this count value with the 
total counter value.)
Item
Trouble
JAM
JAM counter
SPF JAM
SPF JAM counter
TROUBLE
Trouble counter
22-3
Purpose
Adjustment/setting/operation data output/check 
(display/print)
Function 
(Purpose)
Used to check the misfeed positions and the number of 
misfeed at each position. (When the number of 
misfeed is considerably great, it can be judged as 
necessary for repair.)
Item
Trouble
Mis-feed
Sim22-1 COUNTER 1/3
TOTAL   :   nnnnnnn
MAINTE  :   nnnnnnn
DEVE    :   nnnnnnn
DRUM    :   nnnnnnn
Sim22-2 JAM/TROUBLE
JAM     :   nnnnnnn
SPF JAM :   nnnnnnn
TROUBLE :   nnnnnnn
Sim22-3 JAM HIS.1/5
XXXXXXX    XXXXXXX
XXXXXXX    XXXXXXX
XXXXXXX    XXXXXXX
XXXXXXX    XXXXXXX
Display items
Jam contents
1ST_PICK
1st cassette pick-up miss
2ND_PICK
2nd cassette pick-up miss
3RD_PICK
3rd cassette pick-up miss
4TH_PICK
4th cassette pick-up miss
HND_PICK
Multi manual feed pick-up miss
PIN_TOP
Paper-in sensor lead edge jam
PIN_END
Paper-in sensor rear edge jam
PIN_DUP
Paper-in sensor reverse jam
DPX_TOP
Duplex sensor lead edge jam
DPX_END
Duplex sensor rear edge jam
UPO_TOP
Upper stage paper exit lead edge jam
UPO_END
Upper stage paper exit rear edge jam
LPO_TOP
Lower stage paper exit lead edge jam
LPO_END
Lower stage paper exit rear edge jam
PS
Abnormality between PS papers.
2ND_TOP
2nd paper pass lead edge jam
2ND_END
2nd paper pass rear edge jam
3RD_TOP
3rd paper pass lead edge jam
3RD_END
3rd paper pass rear edge jam
4TH_TOP
4th paper pass lead edge jam
4TH_END
4th paper pass rear edge jam
DPX_SHORT
Duplex short scale error
DPX_LONG
Duplex long scale error
DPX_DBLFD
Duplex print remain (double feed) jam
FIN_PIN
Finisher paper entry jam
FIN_ESC
Finisher escape tray jam
FIN_OFST
Finisher offset tray jam
FIN_STPL
Finisher staple tray jam
22-4
Purpose
Adjustment/setting/operation data output/check 
(display/print)
Function 
(Purpose)
Used to check the total trouble (self diag) history.
Item
Trouble
22-5
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Used to check the ROM version of each unit (section).
Item
Software
S/N
Machine serial number
PRINTER
PRINTER
MCU
Main Control Unit
NIC
NIC
IMC
IMC
FINISHER
FINISHER
OPE
Panel
FAX
FAX
Sim22-4 TROUBLE 1/4
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
XX-XX  XX-XX  XX-XX
Sim22-5 ROM VER.1/2
S/N     :0000000000
MCU     :00.00
IMC     :00.00
OPE     :00.00
Page of 58
Display

Click on the first or last page to see other AR-235 (serv.man9) service manuals if exist.