DOWNLOAD Sharp AR-235 (serv.man9) Service Manual ↓ Size: 755.35 KB | Pages: 58 in PDF or view online for FREE

Model
AR-235 (serv.man9)
Pages
58
Size
755.35 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Adjustments, setting Simulation Trouble code list
File
ar-235-sm9.pdf
Date

Sharp AR-235 (serv.man9) Service Manual ▷ View online

AR-235/275 SIMULATION - 24
Operation/procedure
The  operating  conditions  of  sensors  and  detectors  in  the  paper  feed
section of the machine  are displayed. The active sensors and detec-
tors are highlighted.
Width detection size of the manual feed tray (one of them is displayed.)
A4/A3, LT/WLT, B5/B4, INV/LTR, A5/A4R, B5R, POSTCARD, EXTRA
(At detection, highlighted)
Operation/procedure
The status of sensors and detectors in the manual paper feed section
is displayed. The active sensors and detectors are highlighted.
Width detection size of the manual feed tray (one of them is displayed.)
A4/A3, LT/WLT, B5/B4, INV/LTR, A5/A4R, B5R, POSTCARD, EXTRA
Operation/procedure
1) Set A3/W Letter and fit the guide, then press the [OK] key.
2) Set A4R/LetterR and fit the guide, then press the [OK] key.
When the intermediate position adjustment is not performed, press
the [OK] key without changing the guide position.
3) Set to A5R/INVOICE R and fit the guide, then press the [OK] key.
When the intermediate position adjustment is not performed, press
the [OK] key without changing the guide position.
4) Narrow the guide at minimum, press the [OK] key.
5) Set the paper detection width (+), and press the [OK] key.
6) Set the paper detection width (–), and press the [OK] key.
If "FAILED" is displayed in procedure 1), 2), 3), or 4), it is NG of adjust-
ment. Repeat the adjustment.
30-2
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of sensors and detectors 
in the paper feed section and the related circuits. (The 
operations of sensors and detectors in the paper feed 
section can be monitored with the LCD.)
Section
Paper feed
Item
Operation
PED1
1st cassette paper empty sensor
LUD1
1st cassette paper upper limit detection sensor
CD1
1st cassette empty sensor
PED2
2nd cassette paper empty sensor
LUD2
2nd cassette paper upper limit detection sensor
CD2
2nd cassette empty sensor
PFD2
2nd cassette paper pass sensor
DSWR2
2nd cassette right door detection sensor
MPED
Manual tray paper empty detection
MPLS1
Manual tray length detection 1
MPLS2
Manual tray length detection 2
MPLD1
Manual feed paper length detection 1
MPLD2
Manual feed paper length detection 2
40
40-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of the manual paper feed 
tray paper size detector and the related circuit. (The 
operation of the manual paper feed tray paper size 
detector can be monitored with the LCD.)
Section
Paper feed
Item
Operation
MPLS1
Manual tray length 
detection 1
MPLD1
Manual feed paper 
length detection 1
MPLS2
Manual tray length 
detection 2
MPLD2
Manual feed paper 
length detection 2
Sim30-2 TRAY SEN1/2
PED1 LUD1 
CD1
PED2 LUD2 CD2 PFD2
DSWR2
MPED
Sim40-1 MB SENSOR
MPLS1
  MPLS2  MPLD1
MPLD2 
A3/A4
 INV/LTR
B5/B4 LT/WLT A5/A4R
B5R POSTCARD EXTRA
40-2
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the manual paper feed tray paper width 
detector detection level.
Section
Paper feed
Item
Operation
(Maximum position setting 
screen: AB series)
(Maximum position setting screen : 
Inch series)
(Intermediate position L setting 
screen: AB series)
(Intermediate position L setting 
screen: INCH series)
If the intermediate position adjustment is not performed, press the
[OK] key without changing the guide position.
(Intermediate position S setting 
screen: AB series)
(Intermediate position S setting 
screen: INCH series)
If the intermediate position adjustment is not performed, press the
[OK] key without changing the guide position.
(Minimum position setting screen)
(Paper width detection (+) 
setting screen)
(Paper width detection (–) setting 
screen)
The intermediate position adjustment setup YES/NO is displayed.
Sim40-2 MB SENSOR
A3 PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
WLT PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
A4R PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
LTR PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
A5R PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
INVR PAPER SET
PRESS OK KEY
Sim40-2 MB SENSOR
MIN POSITION SET
PRESS OK KEY
Sim40-2 MB SENSOR
PAPER +          60
MID-L ADJ. ON
MID-S ADJ. ON
     [  1- 99]   
60
Sim40-2 MB SENSOR
PAPER-           40
MID-L ADJ. ON
MID-S ADJ. ON
     [  1 -99]   
40
AR-235/275 SIMULATION - 25
Operation/procedure
The AD conversion value of manual feed width detection is displayed.
Operation/procedure
The operation status of the sensors and detectors in the original size
detection section are displayed. The active sensors and detectors are
highlighted.
For AB series, PD1 - 5 is displayed, for inch series, PD1 - 4.
Operation/procedure
Place  an  A3  (or  WLT)  document  on  the  document  table,  and  press
[OK] key with the OC cover open.
The adjustment is performed and the result is displayed.
The value in [ ] shows the threshold value.
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.
Operation/procedure
The detection output level of each sensor is displayed in real time.
The  value  in  [  ]  shows  the  threshold  value  of  20  degree  detection
adjustment.
For AB series, 1 - 5 is displayed, for inch series, PD1 - 4.
Operation/procedure
Set the OC cover at 20 degrees detection and press the [OK] key.
The detection output level of each sensor is displayed in real time.
The  value  in  [  ]  shows  the  threshold  value  of  20  degree  detection
adjustment. 
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.
(Adjustment result screen)
Adjustmen state is displayed.
Paper  width  detection  (+)  adjustment
value
Paper  width  detection  (–)  adjustment
value
Intermediate position L YES : LON 
Intermediate position L NO : LOFF 
Intermediate position S YES : SON
Intermediate position S NO : SOFF
40-3
Purpose
Adjustment
Function 
(Purpose)
The AD conversion value of manual feed width 
detection is displayed.
Section
Paper feed
Item
Operation
41
41-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the document size detection photo 
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted 
display
Close: Normal display
PD1 to 5
Original sensor status
Without original: 
Normal display
With original: 
Highlighted display
41-2
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the detection level of the document size 
photo sensor.
Section
Others
Item
Operation
Sim40-2 MB SENSOR
PAPER +          60
PAPER -          40
COMPLETE
     LON  SON
Sim40-3 MB SENSOR
AD CONVERT VALUE
     [123]
Sim41-1 PD SENSOR
OCSW
  PD1   PD2
PD3   PD4   PD5
(Initial screen)
(Executing screen)
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection 
level
41-3
Purpose
Operation test/check
Function 
(Purpose)
Used to check the light reception level and the 
detection level of the original size detection photo 
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection 
level
41-4
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the detection level of OC 20 degrees.
Section
Others
Item
Operation
(Initial screen)
(Executing screen)
OCSW
Original cover state
Open: Highlighted 
display
Close: Normal display
1 to 5
PD sensor 
detection level
Sim41-2 PD SENSOR
PRESS OK KEY   EXEC
Sim41-4 20˚ SENSOR
PRESS OK KEY  EXEC
AR-235/275 SIMULATION - 26
Operation/procedure (Pattern 2)
After  the  mode  selection,  enter  the  adjustment  value  and  press  the
[OK] key.
Operation/procedure (Pattern 1)
Input the set value with the 10-key and press the [OK] key.
Operation/procedure (Pattern 1)
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Operation/procedure
To support an individual necessity in paper and the environment, it  is
variable  in  the  range  of  5  to  30uA  in  the  increment  of  1uA  in  each
mode.
When changing +V2, check with +V1 unchanged. If there is any trouble
in the half tone image of graphics, keep the relationship between +V1
and +V2 at the default and change it.
When  the  image  quality  is  deteriorated  because  the  user  selects  the
OHP mode and use other than the recommended OHP, decrease the
transfer  current  to  adjust  deterioration  of  black  background  picture
quality. If some of characters are not printed, increase the transfer cur-
rent. 
Operation/procedure
Correction is performed when the temperature sensor installed to the
MCU indicates 15°C or below.
The content of correction is to raise the DVB-Bias and Grid by –50V.
The  simulation  allows  to  vary  the  correction  threshold  value  in  the
range of  0 to 20°C.
43
43-1
Purpose
Setting
Function 
(Purpose)
Used to set the fusing temperature in each operation 
mode.
Section
Fixing (Fusing)
Item
Operation
(Initial screen)
(Input screen)
Display items
Content
Setting range
Default
1:600dpi
600dpi
155-190
185
2:1200dpi
1200dpi
140-190
160
3:POST CARD
Postcard
155-190
185
43-10
Purpose
Setting
Function 
(Purpose)
Used to set the paper feed cycle for postcard.
Section
Paper feed
Item
Operation
Setting range
1-99
Default
50
44
44-1
Purpose
Setting
Function 
(Purpose)
Used to make various setups in each mode of process 
control.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Sim43-1 FUSER TEMP.
1:600dpi        185
2:1200dpi       160
3:POST CARD     185
                 
 2
Sim43-1 FUSER TEMP.
2:1200dpi       160
     [140-190]  
160
Sim43-10 POST CARD
PICK UP CYCLE    50
     [  1- 99]  
 50
Sim44-1 PROCON MODE
ENVIRONMENT ADJ.  1
     [  0-  1]   
 1
Display items
Content
Setting 
range
Default
ENVIRONMENT ADJ.
Environmental correction 
Valid/Invalid
(0: Environmental 
correction invalid
1: Environmental 
correction valid)
0-1
1
44-34
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the transfer current value.
(Initial screen)
(Input/Executing screen)
Display items
Content
Setting 
range
Default
Japan, 
USA
Others
1:+V1 (600)
600dpi +V1
5-30
18
20
2:+V2 F (600)
600dpi +V2 front 
surface
5-30
18
20
3:+V2 R (600)
600dpi +V2 back 
surface
5-30
16
16
4:+V2 S-F(600)
600dpi +V2 small 
size front
5-30
24
24
5:+V2 S-R(600)
600dpi +V2 small 
size back
5-30
18
18
6:+V2 OHP(600)
600dpi +V2OHP
5-30
20
20
7:+V1 (1200)
1200dpi +V1
5-30
8
8
8:+V2 F (1200)
1200dpi +V2 front 
surface
5-30
12
14
9:+V2 R (1200)
1200dpi +V2 back 
surface
5-30
8
8
10:+V2 S-F(1200)
1200dpi +V2 small 
size front
5-30
14
14
11:+V2 S-R(1200)
1200dpi +V2 small 
size back
5-30
12
12
12:+V2 OHP(1200)
1200dpi +V2OHP
5-30
10
10
44-35
Purpose
Setting
Function 
(Purpose)
Correction temperature setup when correcting the 
ambient temperature.
Sim44-34 TC ADJ.
1:+V1    (600)   20
2:+V2 F  (600)   20
3:+V2 R  (600)   18
1/4
Sim44-34 TC ADJ.
4:+V2 S-F(600)   22
     [  5- 30]   
22
AR-235/275 SIMULATION - 27
If, however, the set temperature is increased, correction  at a high volt-
age is performed in normal temperatures.
Operation/procedure (Pattern 1)
Enter the set value with the 10-key, and the set value will be registered.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When  the  [START]  key  is  pressed,  a  print  is  made  and  the  display
returns to the mode selection menu. 
(Auto adjustment)
Setup of various copy conditions: Similar to the normal copy mode.
Use  of  [SPECIAL  FUNCTION]  key,  [JOB  STATUS]  key,  and  [INTER-
RUPT] key is inhibited.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When  the  [START]  key  is  pressed,  a  print  is  made  and  the  display
returns to the mode selection menu.
Setup of various copy conditions: Similar to the normal copy mode.
Use  of  [SPECIAL  FUNCTION]  key,  [JOB  STATUS]  key,  and  [INTER-
RUPT] key is inhibited.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When  the  [START]  key  is  pressed,  a  print  is  made  and  the  display
returns to the mode selection menu.
Setting range
0-20
Default
15°C
44-40
Purpose
Setting
Function 
(Purpose)
Used to set the rotating time before toner supply.
Setting range
1-99
Default
8
46
46-2
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the copy exposure level.
Item
Picture quality
Density
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting 
range
Default
1:AE
AE
1-99
50
2:TEXT
Character
Level 3.0
3:TEXT/PHOTO
Character/Photo
Level 3.0
4:PHOTO
Photo
Level 3.0
5:SUPER PHOTO
Super photo
Level 3.0
6:AE(TS)
AE (TS)
7:TEXT(TS)
Character (TS)
Level 3.0
8:TEXT/PHOTO(TS)
Character/Photo (TS)
Level 3.0
46-7
Purpose
Adjustment
Function 
(Purpose)
Used to adjust individually the copy exposure level. 
(Super photo)
Item
Picture quality
Density
Sim44-35 ENV.ADJ.
DVB/GRID ENV TMP 15
     [  0- 20]   
15
Sim44-40 TONER
ROTATE TIME      50
     [  1- 99]  
  8
Sim46-2 EXP. LEVEL
1:AE             
50
2:TEXT           50
3:TEXT/PHOTO     50
1/3             
 50
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting 
range
Default
1:1.0(SHIFT)
Super photo level 1.0 (shift q’ty)
1-99
32
2:1.0(GAMMA)
Super photo level 1.0 (slant)
1-99
50
3:2.0(SHIFT)
Super photo level 2.0 (shift q’ty)
1-99
41
4:2.0(GAMMA)
Super photo level 2.0 (slant)
1-99
50
5:3.0(SHIFT)
Super photo level 3.0 (shift q’ty)
1-99
50
6:3.0(GAMMA)
Super photo level 3.0 (slant)
1-99
50
7:4.0(SHIFT)
Super photo level 4.0 (shift q’ty)
1-99
56
8:4.0(GAMMA)
Super photo level 4.0 (slant)
1-99
61
9:5.0(SHIFT)
Super photo level 5.0 (shift q’ty)
1-99
62
10:5.0(GAMMA)
Super photo level 5.0 (slant)
1-99
66
46-9
Purpose
Adjustment
Function 
(Purpose)
Used to adjust individually the copy exposure level. 
(Character)
Item
Picture quality
Density
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting 
range
Default
1:1.0(SHIFT)
Character level 1.0 (shift 
q’ty)
1-99
22
2:1.0(GAMMA)
Character level 1.0 (slant)
1-99
44
3:2.0(SHIFT)
Character level 2.0 (shift 
q’ty)
1-99
36
4:2.0(GAMMA)
Character level 2.0 (slant)
1-99
47
5:3.0(SHIFT)
Character level 3.0 (shift 
q’ty)
1-99
50
6:3.0(GAMMA)
Character level 3.0 (slant)
1-99
50
7:4.0(SHIFT)
Character level 4.0 (shift 
q’ty)
1-99
61
8:4.0(GAMMA)
Character level 4.0 (slant)
1-99
55
9:5.0(SHIFT)
Character level 5.0 (shift 
q’ty)
1-99
72
10:5.0(GAMMA)
Character level 5.0 (slant)
1-99
60
11:TS 1.0(SHIFT)
Character (TS) level 1.0 
(shift q’ty)
1-99
22
12:TS 1.0(GAMMA)
Character (TS) level 1.0 
(slant)
1-99
44
13:TS 2.0(SHIFT)
Character (TS) level 2.0 
(shift q’ty)
1-99
36
14:TS 2.0(GAMMA)
Character (TS) level 2.0 
(slant)
1-99
47
Sim46-7 SUPER PHOTO
1:    1.0(SHIFT) 
50
2:    1.0(GAMMA) 50
3:    2.0(SHIFT) 50
1/4              
50
Sim46-9 TEXT
1:    1.0(SHIFT)
 50
2:    1.0(GAMMA) 50
3:    2.0(SHIFT) 50
1/7             
 50
Page of 58