Sharp AR-235 (serv.man9) Service Manual ▷ View online

AR-235/275 ADJUSTMENTS - 1
[7] ADJUSTMENTS, SETTING
1. List of adjustment items
2. Copier adjustment
A. Process section
(1) Developing doctor gap adjustment
1) Loosen the developing doctor fixing screw A.
2) Insert a thickness gauge of 1.5mm to the three positions at 20mm
and 150mm from the both ends of the developing doctor as shown.
3) Tighten the developing doctor fixing screw.
4) Check  the  clearance  of  the  developing  doctor.  If  it  is  within  the
specified range, then fix the doctor fixing screw with screw lock.
When  inserting  a  thickness  gauge,  be  careful  not  to  scratch  the
developing doctor and the MG roller.
<Adjustment specification>
(2) MG roller main pole position adjustment
1) Put the developing unit on a flat surface.
2) Tie a needle or pin on a string.
3) Hold the string and bring the needle close to the MG roller horizon-
tally. (Do not use paper clip, which is too heavy to make a correct
adjustment.)  (Put  the  developing  unit  horizontally  for  this  adjust-
ment.)
4) Do not bring the needle into contact with the MG roller, but bring it
to a position 2 or 3mm apart from the MG roller. Mark the point on
the MG roller which is on the extension line from the needle tip.
5) Measure  the  distance  from  the  marking  position  to  the  top  of  the
doctor plate of the developing unit to insure that it is 18mm.
If  the  distance  is  not  within  the  specified  range,  loosen  the  fixing
screw A  of  the  main  pole adjustment plate,  and move  the  adjust-
ment plate in the arrow direction to adjust.
Section
Adjustment item
Adjustment procedure/SIM No.
A
Process section
(1)
Developing doctor gap adjustment
Developing doctor gap adjustment
(2)
MG roller main pole position adjustment
MG roller main pole position adjustment
(3)
Developing bias voltage adjustment
SIM8-1
(4)
Grid bias voltage adjustment (High mode)
SIM8-2
(5)
Grid bias voltage adjustment (Low mode)
SIM8-3
B
Mechanism section
(1)
OC image lead edge position/Sub scanning 
magnification ratio/Original offset auto adjustment
SIM48-3
(2)
Print start position adjustment
SIM50-5
(3)
SPF image lead edge position adjustment
SIM50-6
(4)
Rear edge void adjustment
SIM50-1-6
(5)
Paper off center adjustment
SIM50-10
(6)
Left edge void area adjustment
SIM50-1-8
(7)
Main scanning direction (FR direction) distortion 
balance adjustment
No. 2/3 mirror base unit installing position 
adjustment
Copy lamp unit installing position adjustment
(8)
Sub scanning direction (scanning direction) 
distortion adjustment
Winding pulley position adjustment
(9)
Main scanning direction (FR direction) distortion 
adjustment
Rail height adjustment
(10)
Main scanning direction (FR direction) 
magnification ratio adjustment
SIM48-1-1, 48-1-2
(11)
Sub scanning direction (scanning direction) 
magnification ratio adjustment
a
OC mode in copying (SIM 48-1-3)
b
RSPF sub scanning direction magnification ratio 
(SIM48-1-4, 48-1-5)
(12)
Off center adjustment (SPF mode)
SIM50-12
(13)
OC (SPF) open/close detection position adjustment
SIM41-3
(14)
Original sensor adjustment
SIM41-2, 41-4
(15)
SPF white correction pixel position adjustment 
(required in an SPF model when replacing the lens 
unit)
SIM63-7
C
Image density 
(exposure) adjustment
(1)
Copy mode
SIM46-2
20mm
10mm
150mm
10mm
20mm
F
C
R
DG:1.5
+0.1
- 0.15
DG:1.5
+0.1
- 0.15
DG:1.55
+0.15
- 0.2
Developing doctor gap
F/R both ends (20mm from the both ends):1.5
+0.1mm
-0.15mm
C (Center)(150mm from the both ends):
1.55
+0.15mm
-0.2mm
AR-235/275 ADJUSTMENTS - 2
(3) Developing bias voltage adjustment (SIM 8-1)
1) Execute SIM 8-1.
2) After selecting the mode, enter the adjustment value and press the
[OK] key.
3) Output will be made for 30 sec.
<Adjustment specification>
(4) Grid bias voltage adjustment
 
(High mode) (SIM 8-2)
1) Execute SIM 8-2.
2) After selecting the mode, enter the adjustment value and press the
[OK] key.
3) Output will be made for 30 sec.
<Adjustment specification>
The input value is in the increment of –25V.
(5) Grid bias voltage adjustment (Low mode) (SIM 8-3)
1) Execute SIM 8-3.
2) After selecting the mode, enter the adjustment value and press the
[OK] key.
3) Output will be made for 30 sec.
<Adjustment specification>
The input value is in the increment of –25V.
B. Mechanism section
(1) OC image lead edge position/Sub scanning 
magnification ratio/Original offset auto adjustment
1) Set the test chart (UKOG-0011QSZZ) on the OC table. 
2) Execute SIM 48-3.
3) Make a copy.
(2) Print start position adjustment
1) Execute SIM 50-5.
Select  the  mode  with  the  arrow  keys,  enter  the  adjustment  value
with the 10-key, and press the [OK] key.
Pressing the [START] key makes a print.
Pressing the [RETURN] key returns to the mode selection.
Setup of various copy conditions: Similar to the normal copy mode.
2) Measure  the  distance  H  between  the  paper  lead  edge  and  the
image  print  start  position.  Set  the  image  print  start  position  set
value again.
• 1 step of the set value corresponds to about 0.127mm shift.
• Calculate the set value from the formula below.
Display items
Content
Installation 
range
Default
1:AE
AE
200-550
426 (–426V)
2:TEXT
Character
450 (–450V)
3:TEXT/PHOTO
Character/Photo
450 (–450V)
4:PHOTO
Photo
450 (–450V)
5:SUPER PHOTO
Super photo
400 (–400V)
6:TONER SAVE
Toner save
376 (–376V)
Display items
Content
Setting 
range
Default
1:AE
AE
1-8
4 (–555V)
2:TEXT
Character
5 (–580V)
3:TEXT/PHOTO
Character/Photo
5 (–580V)
4:PHOTO
Photo
5 (–580V)
5:SUPER PHOTO
Super photo
3 (–530V)
6:TONER SAVE
Toner save
2 (–505V)
A
Sim8-1 DV BIAS COPY
1:AE            426
2:TEXT          450
3:TEXT/PHOTO    450
1/2
Sim8-2 MHV(H) COPY
1:AE              3
2:TEXT            5
3:TEXT/PHOTO      5
1/2
Display items
Content
Setting 
range
Default
1:AE
AE
1-8
4 (–426)
2:TEXT
Character
5 (–450)
3:TEXT/PHOTO
Character/Photo
5 (–450)
4:PHOTO
Photo
5 (–450)
5:SUPER PHOTO
Super photo
3 (–400)
6:TONER SAVE
Toner save
2 (–375)
(Initial screen)
(Input screen)
(Executing screen)
Display 
items
Content
Setting 
range
Default
1:TRAY1
1st cassette
0-99
53
2:OPTION
Option cassette
1-99
3:MANUAL
Manual feed
4:DUPLEX
Back print
Sim8-3 MHV(L) COPY
1:AE              3
2:TEXT            5
3:TEXT/PHOTO      5
1/2
Set the 
test chart
Sim50-5 PRINT EDGE
1:TRAY1          
50
2:OPTION         50
3:MANUAL         50
1/2              
50
AR-235/275 ADJUSTMENTS - 3
99  –  H/0.127  (mm)  =  Image  print  start  position  set  value  <H:
Print start position measurement value (mm)>
Fit the print edge with the paper edge, and perform the lead
edge adjustment.
Example:99 – 5/0.127 = 99 – 39.4 = about 59
 FIf the set value is not obtained from the above formula, per-
form the fine adjustment.
3) Execute SIM 50-1-2 to adjust the main cassette lead edge void.
• 1 step of the set value corresponds to about 0.127mm shift.
• Calculate the set value from the formula below.
B/0.127 (mm) = Lead edge void adjustment value <B: Lead edge
void (mm)>
Example: When setting the lead edge void to 2.5mm:
2.5 /0.127 = about 20
<Adjustment specification>
(3) SPF image lead edge position adjustment
1) Set a scale on the OC table as shown below.
 Since the printed copy is used as a test chart, put the scale in
paralleled with the edge lines.
2) Make a copy, then use the copy output as an original to make an
SPF copy again.
3) Check the copy output. If necessary, perform the following adjust-
ment procedures.
4) Execute SIM 50-6.
5) Set the SPF lead edge position set value so that the same image is
obtained  as  that  obtained  in  the  previous  OC  image  lead  edge
position adjustment.
<Adjustment specification>
(4) Rear edge void adjustment
1) Set a scale as shown in the figure below.
2) Set  the  document  size  to  A4  (8.5"  x  11"),  and  make  a  copy  at
100%.
3) If an adjustment is required, follow the procedures below.
4) Execute  SIM  50-1  and  set  the  density  mode  to  DEN-B.  The  cur-
rently set adjustment value is displayed.
5) Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
(5) Paper off center adjustment
1) Perform this adjustment after execution of SIM 48-3.
2) Set a test chart (UKOG-0089SCZZ) on the document table.
3) Select a paper feed port and make a copy.
Compare the copy and the test chart. If necessary, perform the follow-
ing adjustment procedure.
4) Execute SIM 50-10.
Select  the  mode  with  the  arrow  keys,  enter  the  adjustment  value
with the 10-key, and press the [OK] key.
Pressing the [START] key makes a print.
Pressing the [RETURN] key returns to the mode selection.
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
Main cassette 
lead edge void
50-1-
2
B/0.127
Lead edge void: 
1 to 4mm
Image loss: 3mm 
or less
1 – 99
Print start 
position
50-5
99 – H/0.127
5
10
0mm
0mm
5
10
2.5mm
2.5mm
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
SPF image 
lead edge 
position
50-6
1 step: 
0.127mm 
shift
Lead edge void:  
1 – 4mm
Image loss: 3mm or less
1 – 99
Adjustment 
mode
SIM
Set value
Spec 
value
Setting 
range
Rear edge 
void
50-1-6
1 step: 0.127mm 
shift
4mm or 
less
1 – 99
(Initial screen)
(Input screen)
(Executing screen)
A4 (8.5"  x 11")
Paper rear edge
Void amount (Standard value: 4mm or less)
Scale image
Paper rear edge
Sim50-10 PRT.CENTER
1:BYPASS         
50
2:TRAY1          50
3:TRAY2          50
1/2              
50
AR-235/275 ADJUSTMENTS - 4
Setup of various copy conditions: Similar to the normal copy mode.
<Adjustment specification>
(6) Left edge void area adjustment
Note: Before  performing  this  adjustment,  be  sure  to  check  that  the
paper off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089SCZZ) on the document table.
2) Select a paper feed port and make two copies.
Compare  the  second  copy  and  the  test  chart.  If  necessary,  per-
form the following adjustment procedure.
The first copy does not show the void. Be sure to check the second
copy.
3) Execute SIM 50-1.
Select  the  mode  with  the  arrow  keys,  enter  the  adjustment  value
with the 10-key, and press the [OK] key.
Pressing the [START] key makes a print.
Pressing the [RETURN] key returns to the mode selection.
Setup of various copy conditions: Similar to the normal copy mode.
<Adjustment specification>
(7) Main scanning direction (FR direction) distortion 
balance adjustment
1) Remove the OC glass and the right cabinet.
2) Loosen the copy lamp unit wire fixing screw.
Display 
items
Content
Setting 
range
Default
1:BYPASS
Manual feed
1-99
50
2:TRAY1
1st cassette
3:TRAY2
2nd cassette
4:TRAY3
3rd cassette
5:TRAY4
4th cassette
6:DUPLEX
Back print
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
Paper off 
center
50-10
-2
Add 1: 0.127mm 
shift to R side.
Reduce 1: 
0.127mm shift to L 
side.
Single: 
Center 
±2.0mm
1 – 99
Second 
print surface 
off-center
50-10
-6
Duplex: 
Center 
±2.5mm
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting 
range
Default
1:RRC-A
Original scan start position 
adjustment
1-99
43
2:RRC-B
RRC cancel adjustment 
(Main cassette)
1-99
18
3:RRC-MANUAL
RRC cancel adjustment 
(Manual feed cassette)
1-99
18
4:RRC-OPTION
RRC cancel adjustment 
(Option cassette)
1-99
18
5:RRC-DUPLEX
RRC cancel adjustment 
(back of the machine)
1-99
18
6:DEN-B
Rear edge void adjustment
1-99
30
7:DEN-B-DUP
Rear edge void adjustment 
(Duplex)
1-99
50
8:SIDE VOID
Left edge void adjustment 
(First print surface)
1-99
18
9:SIDE VOID-DUP
Left edge void adjustment 
(Duplex)
1-99
18
10:LOSS(OC)
Image loss quantity 
adjustment
1-5
3
Sim50-1 LEAD EDGE
1:RRC-A          
43
2:RRC-B          18
3:RRC-MANUAL     18
1/4  [  1- 99]   
43
Adjustment 
mode
SIM
Set value
Spec 
value
Setting 
range
Left edge void
50-1-
8
1 step: 0.127mm 
shift
0.5 – 4mm
1 – 99
2)
1)
1)
3)
5)
1)
1)
4)
Wire fixing screw
Page of 58
Display

Sharp AR-235 (serv.man9) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-235 (serv.man9) Service Manual ↓ Size: 755.35 KB | Pages: 58 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-235 (serv.man9) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-235 (serv.man9) Copying Equipment. Information contained in Sharp AR-235 (serv.man9) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.