PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING    2 - 13 
 
PICTURE menu 
Function
 
Command
 
Direction
Parameter
 
Reply
 
Control/Response contents
 
BRIGHT
 
VLMP(#) 
WR 
0~ 31 
0~ 31 
   
○ 
CONTRAST
 
CONT 
WR 
0  ~ 100 
0  ~ 100 
   
BLACK LEVEL
 
BLVL 
WR 
0  ~ 100 
0  ~ 100 
   
TINT (HDMI)
 
TINT 
WR 
0  ~ 100 
0  ~ 100 
   
COLORS (HDMI)
 
COLR 
WR 
0  ~ 100 
0  ~ 100 
   
COLOR 
ADJUSTMENT
 
COLOR MODE 
BMOD(#) 
WR 
STD
 
 
 
VIVID
 
 
 
sRGB (When the input mode is DVI-D, 
D-SUB[RGB])
 
 
 
HIGH ILLUMINANCE
 
 
 
USB 
WHITE 
BALANCE
 
THRU
 
CTMP 
WR 
   
PRESET
 
 
 
1~ 18 
1~ 18 
From 1: approximately 3,000K to 15: 
approximately 10,000K (500K steps) 
16: approximately 5,600K, 17: approximately 
9,300K, 18: approximately 3,200K
 
USER
 
 
 
99 
99 
   
GAMMA
 
 
GAMM 
WR 
0  ~  2、5 
0  ~  2、5 
0:1.8、1:2.2、2:2.4、5:2.0 
RESET
 
ARST 
 
   
- 
 
AUDIO menu 
Function
 
Command
 
Direction
Parameter
 
Reply
 
Control/Response contents
 
TREBLE 
AUTR 
WR 
0  ~ 100 
0  ~ 100 
 
○ 
BASS 
AUBS 
WR 
0  ~ 100 
0  ~ 100 
 
RESET 
ARST 
 
 
- 
 
: ‘14/September 
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING    2 - 14 
 
SETUP menu 
Function
 
Command
 
Direction
Parameter
 
Reply
 
Control/Response contents
 
*
DATE/TIME SETTING
 
DATE 
WR 
AABBCCDDEE 
AABBCCDDEE 
AA: Year, BB: Month, CC: Day, DD: Hour, EE: 
Minute
 
SCHEDULE
 
SH01  ~ 
 
  SH03 
WR 
ABBCCDDEEF 
GHIJKLMNO 
ABBCCDDEEF 
GHIJKLMNO 
Schedule of a specified number 
A : Schedule 0= Not effective, 1 = Effective 
B : Power-on hour 00-23, 99 = Not effective 
C : Power-on minute 00-59, 99 = Not effective 
D : Power-off hour 00-23, 99 = Not effective 
E : Power-off minute 00-59, 99 = Not effective 
F : Input 0 = Not specified, 1 = DVI-D, 3 = HDMI, 4 
= D-SUB, 
5 = USB 
G : EVERY DAY 0 = OFF, 1 = ON 
H : EVERY WEEK 0 = OFF, 1 = ON 
I-O : MON-SUN 0 = OFF, 1 = ON
 
LANGUAGE
 
LANG 
WR 
14 
14 
ENGLISH
 
DEUTSCH 
FRANCAIS 
ITALIANO 
ESPANOL 
РУССКИЙ
 
日本語 
INPUT SELECT
 
HDMI 
HDSL 
WR 
0~1 
0~1 
0:PC、1:AV 
DVI-D 
SLDS 
WR 
0~2 
0~2 
0:RGB、1:COMPONENT 
2:VIDEO 
AUDIO OPTION
 
SPEAKER 
SELECT
 
SPSL 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
AUDIO OUTPUT
 
AOUT 
WR 
0~ 31 
0~ 31 
   
ID SETTING
 
ID NO.SETTING
 
IDST 
0~ 25 
 
Sets the monitor’s ID number. (“0” means “no ID 
number”.)
 
 
0~ 25 
Returns the monitor’s ID number.
 
ID NO. SETTING 
(ONCE)
 
IDSL 
1~ 25 
 
Sets a monitor ID number. 
This ID number is only effective for the command 
immediately after this command.
 
 
Clears the ID number if one has been designated.
 
ID NO. SETTING 
(SUBSEQUENT)
 
IDLK 
1~ 25 
 
Sets a monitor ID number. 
This ID number is effective for the next and all 
subsequent commands after this command.
 
 
Clears the ID number if one has been designated.
 
MULTI
 
ENLARGE
 
ENLG 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
ENLARGE MODE
 
EMHV 
WR 
11  ~ 55 
11  ~ 55 
1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, 
where m and n are the numbers of monitors 
specified for the longest direction and the shortest 
direction respectively.)
 
IMAGE POSITION 
(M x N)
 
EPHV 
WR 
11  ~ 55 
11  ~ 55 
Specifies values in the order of IMAGE POSITION 
IN LONGEST/ SHORTEST DIRECTION.
 
BEZEL ADJUST
 
BZCO 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
ENLARGE/ 
IMAGE POSITION 
SETTING
 
ESHV 
WR 
XXYY 
XXYY 
XX: ENLARGE MODE (Same as EMHV), YY: 
IMAGE POSITION (Same as EPHV)
 
THERMAL SENSOR SETTING
 
STDR(#) 
WR 
0~1 
0~1 
0: LANDSCAPE, 1: PORTRAIT
 
 
: ‘14/September 
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING    2 - 15 
 
 
Function
 
Command
 
Direction
Parameter
 
Reply
 
Control/Response contents
 
*
STANDBY MODE
 
STBM 
WR 
0~1 
0~1 
0: STANDARD, 1: LOW POWER
 
OFF IF NO OPERATION
 
ATOF 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
POWER ON DELAY
 
PWOD 
WR 
0~ 60 
0~ 60 
0: OFF, 1-60 seconds
 
AUTO INPUT CHANGE
 
AICO 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
ADJUSTMENT 
LOCK
 
MONITOR 
BUTTONS
 
ALCM(#) 
WR 
0  ~  1、3 
0  ~  1、3 
0: UNLOCK, 1: LOCK ALL, 3: LOCK BUT POWER
REMOTE 
CONTROL
 
ALCR(#) 
WR 
0~3 
0~3 
0: UNLOCK, 1: LOCK ALL, 2: LOCK EXCEPT 
VOLUME, 3: LOCK EXCEPT POWER
 
LED 
OFLD 
WR 
0~1 
0~1 
0: ON, 1: OFF
 
POWER MANAGEMENT 
(HDMI, DVI-D, D-SUB[RGB])
 
PMNG 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
POWER MANAGEMENT 
(D-SUB[COMPONENT], D-SUB[VIDEO])
 
PMAV 
WR 
0~1 
0~1 
0: OFF, 1: ON
 
AUTO PLAY
 
 
WR 
0~1 
0~1 
0: PHOTO, 1: MOVIE
 
ALL RESET
 
RSET 
 
1: ALL RESET
 
 
Others 
Function
 
Command
 
Direction
Parameter
 
Reply
 
Control/Response contents
 
*
VOLUME
 
VOLM(#) 
WR 
0~ 31 
0~ 31 
   
MUTE
 
MUTE(#) 
WR 
0~1  
0~1  
0: OFF, 1: ON
 
INFORMATION
 
MODEL
 
INF1 
 
Value
 
SERIAL NO 
SRNO 
 
Value
 
MAC ADDRESS 
RMAC 
 
Value
 
   
FIRM VERSION 
FMVR 
 
Value
 
   
TEMPERATURE SENSOR
 
DSTA 
 
Internal temperature normal
 
 
 
 
Internal temperature abnormal has occurred and 
the monitor is in standby mode
 
 
 
 
Internal temperature abnormal occurred (To delete 
the information of temperature 
abnormal, turn off the main power.)
 
 
 
 
Internal temperature abnormal has occurred and 
backlight brightness is dimmed
 
 
 
 
Temperature sensor abnormal
 
TEMPERATURE ACQUISITION
 
ERRT 
 
Value
 
Returns the temperature at the temperature 
sensors in the following format. 
[Sensor 1] [Sensor 2] 
Indicates a temperature sensor abnormality when 
“126” is returned.
 
CAUSE OF LAST STANDBY MODE
 
STCA 
 
Initialization
 
 
 
No detectable error has occurred
 
 
 
 
Standby mode by POWER button
 
 
 
 
Standby mode by RS-232C or LAN
 
 
 
 
Input signal waiting mode by No Signal
 
 
 
 
Standby mode by abnormal temperature
 
 
 
 
Standby mode by SCHEDULE setting
 
 
 
 
20 
Standby mode by OFF IF NO OPERATION setting
<MEMO> 
• With some commands, the settings of an item are not continuous. In that case, the entered parameter will be set to the closest setting. 
(Example) When the settings are “...45, 50, 55...” : 
The entered parameter is “50”, “51”, or “52”, “50” is set. 
The entered parameter is “53”, “54”, or “55”, “55” is set. 
• With some commands, the number set in the menu screen may differ from the number of the parameter. 
: ‘14/September 
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING    2 - 16 
 
Controlling the Monitor with a PC (LAN) 
Your monitor can be connected to a LAN allowing you to control it from a PC on the LAN. 
The connection requires a commercially available LAN cable (UTP cable, Category 5, straight through). 
 
<MEMO> 
• You must assign an IP address to the monitor by following the procedures in “Settings to connect to a LAN”. (See the description on the 
right.) 
• Your PC must be installed with Internet Explorer (version 7.0 or later). 
- Version 7, 8, or 9 of Internet Explorer is recommended. 
- Use Internet Explorer Version 10 in compatibility mode. 
• To control the monitor via LAN, set STANDBY MODE to STANDARD. 
• You cannot use RS-232C and LAN control simultaneously. 
Page of 118
Display

Click on the first or last page to see other PN-Y325 service manuals if exist.