CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 11
4. INTERFACE PWB (R903 ONLY)
1 ) Disconnect five connectors, remove four screws (M3 x 6 SW+W, Silver), and remove the interface PWB.
CAUTION
SCREW TIGHTENING TORQUE
    
0.55 - 0.65N•m
MAIN DC POWER 
5. SYSTEM POWER UNIT (R903 ONLY)
■ PN-R903
1 ) Disconnect five connectors, remove nine screws (M3 x 6 SW+W, Silver), and remove the system power unit.
CAUTION
NOTE FOR ASSEMBLY
    
Fix the screws and the hex spacers in the sequence of 1323334, then fix the other screws.
SCREW TIGHTENING TORQUE
    
0.55 - 0.65N•m
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 12
6. 5V POWER SUPPLY UNIT (R703/R603 ONLY)
1 ) Disconnect two connectors, remove four screws (M3 x 6 SW+W, Silver), and remove the 5V power supply unit.
CAUTION
SCREW TIGHTENING TORQUE
    
0.55 - 0.65N•m
7. C-PWB UNIT
■ PN-R903
1 ) Disconnect two connectors, remove four screws (M3 x 6, Silver), and remove the C-PWB cover.
CAUTION
SCREW TIGHTENING TORQUE
    
0.7 - 0.9N•m
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 13
2 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.5 - 0.65N•m
■ PN-R703/R603
1 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.4 - 0.58N•m
Screw x 6
Connector x 2
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 13
2 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.5 - 0.65N•m
■ PN-R703/R603
1 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.4 - 0.58N•m
Screw x 6
Connector x 2