Sharp PN-R603 (serv.man5) Service Manual ▷ View online
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-R903/R703/R603 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 38
<CHECKING CONNECTION BETWEEN C-PWB AND FFC/LVDS>
・
Connect straightly and completely.
・
Connector of FFC has holding mechanism. Holding part must not be loose.
EXAMPLES OF IRRELEVANT STATE
・
Connector is not inserted completely.
・
Connector is not inserted straightly.
・
Holding part is loose.
<CONNECTION BETWEEN CN202 OF C-PWB AND JIG (0RBIH12486///)> (ONLY PN-R903)
MEMO
・
Jig can be set regardless of presence of C-PWB cover.
■ Adjustment
1 ) Display flicker pattern with service tool.
2 ) Change the value roughly from min. to max. (with [UP+5] or
[DOWN-5] button) and watch display.
3 ) Degree of flicker changes as the value change.
4 ) Search approximate value which flicker is least at center of the dis-
play (with [UP+5] or [DOWN-5] button).
5 ) In addition to above, Search value which flicker is least at the cen-
ter of the display (with [UP+1] or [DOWN-1] button) in detail.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-R903/R703/R603 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 39
■ Conditions
・
Viewing distance : 0.35±0.1 [m]
・
Viewing angle : 0degree and ±45 - 80degree
・
Criteria : visual observation
■ Background
・
The way of driving TFT-LCD panel is AC drive to prevent seize.
・
For example AC drive is that voltage applied to TFT change from +B [V] to 0 [V] in time for 100% signal level. And the reference voltage
is +A [V] (=B/2).
・
0 [V] is not change among TFT-LCD panels.
・
Though input voltage is +B[V], actual voltage applied to TFT is change among panels.
・
If the reference voltage is fixed to +A[V], DC may generated. Because difference of voltage (A-0) is not equal to (B-A).
・
Because DC may occur seize, the reference voltage should be adjusted with dedicated pattern to be center of 0[V] and +B[V].
・
The reference voltage is called VCOM. VCOM is adjusted in flicker adjustment.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-R903/R703/R603 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 40
18 - 1. OPERATING
CONDITIONS
FOR
THE FLICKER ADJUSTMENT TOOL
The operating conditions of the Flicker adjustment tool of the informa-
tion display are as follows.
tion display are as follows.
*1 : For PN-R903, you need to use the adjustment tool.
■ When connected to the information display
with an RS-232C cable
with an RS-232C cable
The required RS-232C cable is as shown below. Connect the PC’s
COM port and the RS-232C input terminal of the display with the cable.
COM port and the RS-232C input terminal of the display with the cable.
■ When connected to the information display
with a LAN cable
with a LAN cable
To use a LAN communication, settings must be made both in the PC side
and in the display side.
For details of LAN, refer to following description.
and in the display side.
For details of LAN, refer to following description.
Refer to the Operating Manual.
MEMO
・
It does not operate normally in the power standby state or the
signal standby state. Provide a signal to the current input or
set the power management to “NO.”
18 - 2. BOOTING PROCEDURES OF THE
FLICKER ADJUSTMENT TOOL
Press [Flicker Adjustment] button of the service tool launcher and the
following message is displayed. Check to confirm that a jig is installed,
and press [OK] button.
following message is displayed. Check to confirm that a jig is installed,
and press [OK] button.
18 - 3. FLICKER ADJUSTMENT PROCE-
DURES
The flicker adjustment procedures by use of the flicker adjustment tool
are as follows:
are as follows:
1 ) Press [Connection Setting] button, and perform the communication
setting.
2 ) Press [Flicker] button, and the adjustment pattern is displayed
on the monitor and [Flicker] button turns to yellow-green color.
In addition, the current adjustment value is stored in Reg Value
(VCOM value) and [UP+1], [UP+5], [DOWN-1], [DOWN-5], and
OS
(32bit Only)
n
Windows XP
n
Windows Vista
n
Windows 7
An authorized copying and distribution pack-
age of Microsoft Visual C++ 2005 or later is
required to be installed.
age of Microsoft Visual C++ 2005 or later is
required to be installed.
Communication
port
n
RS-232C port recognized as a COM port
(Which allows communication in 9600/19200/
38400bps.)
(Which allows communication in 9600/19200/
38400bps.)
n
LAN
Jig
To use this tool, a jig is required. *1
RS-232C cable
Straight cable (D-SUB 9 pin female - female)
JIG CONFIRMATION MESSAGE
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-R903/R703/R603 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 41
[Write] buttons are enabled.
3 ) When [UP+1] or [UP+5] button is pressed, the Reg Value is
increased by 1 or 5 respectively (up to max. 127). When [DOWN-1]
or [DOWN-5] button is pressed, the Reg Value is decreased by 1 or
5 respectively (up to min. 0).
1 ) When [Write] button is pressed, the Reg Value is written as the
adjustment value.
2 ) When [Flicker] button is pressed again, the adjustment pattern on
the monitor disappears and [Flicker] button turns to gray color. In
addition, the Reg Value is deleted and [UP+1], [UP+5], [DOWN-1],
[DOWN-5], and [Write] buttons are disabled.
addition, the Reg Value is deleted and [UP+1], [UP+5], [DOWN-1],
[DOWN-5], and [Write] buttons are disabled.
3 ) When [Exit] button is pressed, the tool is terminated. When the tool
is terminated with the adjustment pattern on the monitor displayed,
the adjustment pattern on the monitor is deleted.
the adjustment pattern on the monitor is deleted.
MEMO
・
When the tool is used in a LAN connection, if a certain time
passes without any operation, the connection is closed.
If, therefore, the adjustment is failed, press [Flicker] button and
Click on the first or last page to see other PN-R603 (serv.man5) service manuals if exist.