CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 60
22. MAIL DESCRIPTION CONTENT
This machine is provided with the functions which send the following mails;
n
Periodic send mails which notify the display status periodically on the specified day of week and the specified time
n
Abnormality notification mail which notifies an abnormality when there is any abnormality in the display
The contents described in the above mails are explained here.
22 - 1. ACTUAL MAIL CONTENTS
The format of the mail text is as shown below, which is common to the periodic send mails and the abnormality notification mails.
The contents are in English only.
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
ȷȷȷ
Ჴ.%&/QPKVQT'TTQT4GRQTV
/QPKVQT0COG20::::
/QFGN20::::
5GTKCN0Q
/#%#FFTGUU##$$%%&&''((
+2#FFTGUU
+&0Q
2QYGT10
+PRWV2%&57$
5K\G9KFG
%QNQT/QFG5VCPFCTF
$TKIJV
8QNWOG
+PRWV5KIPCNZ
5VCVWU1-
6GOR1-
ˑӸ
1
2
3
4
5
6
7
8
9
F
G
H
I
J
K
L
M
N
O
P
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 61
1 Subject
n
Periodic send mail: LCD Monitor Report
n
Abnormal notification mail: LCD Monitor Error Report
2 Monitor Name
Name of the set display
The factory setting is the same as the model name.
The factory setting is the same as the model name.
3 Model
“Model name” set in the factory
4 Serial No.
Serial number
5 MAC Address
MAC address (EUI48 ID code) set in the factory
6 IP Address
IP address set in the network connection
7 ID No.
ID No. set in that when connecting monitors in a daisy chain.
8 Power
Power status
ON when the power is turned ON, and OFF when the power is turned off.
9 Input
Input mode
One of the following 9 kinds of the input mode is described.
n
PC DVI-D
n
PC HDMI
n
PC D-SUB
n
PC RGB
n
AV DVI-D
n
AV HDMI
n
AV COMPONENT
n
AV S-VIDEO
n
AV VIDEO
F Size
Screen size
One of the following 6 kinds is described.
n
Wide
n
Zoom1
n
Zoom2
n
Normal
n
DotbyDot
G Color Mode
Color mode
One of the following 4 kinds is described.
n
Standard
n
Vivid
n
sRGB
n
High Illuminance
H Bright
Brightness
The set value of “0” - “31” is described.
I Volume
Sound volume
The set value of “0” - “31” is described.
J Input Signal
Input signal
n
1280 x 1024
n
1080p 60Hz
etc.
When there is no input signal, a space is displayed.
K Status
Hardware abnormality status
When there is no abnormality, “OK” is described. When there is any abnormality, “NG” is described.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 62
L Status Code
The current status of the hardware or the abnormality history is shown with codes.
If there has been no abnormality at all, the status code is as follows:
“0000 - 0000 - 0000 - 0000”
“0000 - 0000 - 0000 - 0000”
If there has been any abnormality, the status code is as follows:
A Hardware monitoring result
Abnormality position bits are assigned as shown in the table below, and it is expressed in hexadecimal of
2 bytes.
Bit
PN-L802B
0
SYSTEM POWER1
1
SYSTEM POWER2
2
SYSTEM POWER3
3
SYSTEM POWER4
4
SYSTEM POWER5
5
BACKLIGHT
6 - 13 Reserved
14
Temperature sensor abnormality
15
Temperature abnormality
B Number of times of reducing the backlight brightness in case of a temperature abnormality
It is displayed up to 2 digits. For more than 99 times, “99” is displayed. For an abnormality notification
mail due to a temperature abnormality, a mail is sent when an abnormality occurs.
Then the number of times of the backlight brightness is revised.
Then the number of times of the backlight brightness is revised.
Therefore, the value immediately before occurrence of the temperature abnormality is displayed.
C Accumulated time of reducing the backlight brightness in case of a temperature abnormality
It is displayed up to 2 digits. For more than 99 hours, “99” is displayed. Similarly to the number of times of
the backlight brightness, the value immediately before occurrence of a temperature abnormality is dis-
the backlight brightness, the value immediately before occurrence of a temperature abnormality is dis-
played.
D Number of times of shifting to the power standby state in case of a temperature abnormality
It is displayed up to 2 digits. For more than 99 times, “99” is displayed. The displayed value is the already
revised value.
revised value.
E Not used for this time. Displayed as “0”.
M Temperature
Temperature abnormality status
This indicates an occurrence of a temperature abnormality of the hardware. If there is no abnormality,
“OK” is displayed. If there is any abnormality, “NG” is displayed.
“OK” is displayed. If there is any abnormality, “NG” is displayed.
N Temp1
This indicates the temperature of the temperature sensor 1.
O Temp 2
The temperature of Temperature Sensor 2 is indicated.
P Temp 3
The temperature of Temperature Sensor 3 is indicated.
A
E
D
C
B
When BACKLIGHT error is detected,;
㸠䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭䇭㸢
䇭bit 0
Bit 15
Example
㵰0020㵱 is displayed.
Example
27
Normal temperature at 27 C
65 (NG)
65
High temperature at 65 C, but it is not
judged as a temperature abnormality.
judged as a temperature abnormality.
ERR
There is a trouble in the temperature sensor,
but it is not judged as an abnormality.
but it is not judged as an abnormality.
ERR (NG) There is a trouble in the temperature sensor,
and it is judged as an abnormality.
It is judged as a temperature abnormality
at 65 C.
at 65 C.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 63
23. NONDISCLOSURE SCREEN OF CONTROLLING THE MONITOR WITH PC (LAN)
CAUTION
n
The screens described in this chapter are not open to the public.
23 - 1. CUSTOM SETTING
For the custom setting, the following web access screen is provided.
■ SMTP-AUTH SETTING
This screen is displayed when the following URL is accessed with a
web browser.
web browser.
http://<IP Address>/custom_smtpauth.cgi
On this screen, the following item can be set.
■ ETHER SETTINGS
This screen is displayed when the following URL is accessed with a
web browser.
http://<IP Address>/custom_ether.cgi
On this screen, the following item can be set.
*
1
This is the factory setting.
23 - 2. SERVICE MENU
For the service menu, the following web access screen is provided.
This screen is displayed when the following URL is accessed with a
web browser.
http://<IP Address>/service.cgi
On this screen, the following item can be set.
Display when a command is sent from the edit box of “COMMAND”
When the command “POWR????” which reads the power status issent.
Example of the display when “1” (Power ON status) is sent back
from the display.
from the display.
Item
Set value range, remark
SMTP-AUTH
Setting to determine whether SMTP-AUTH is
displayed or not in “MAIL” - “ORIGNATOR-
AUTHENTICATION”.
The factory setting is “OFF”
displayed or not in “MAIL” - “ORIGNATOR-
AUTHENTICATION”.
The factory setting is “OFF”
Item
Set value range, remark
MODE
The communication speed of LAN is selected
from the following options:
n
Auto (Automatic setting)
*1
n
100M Full
n
100M Half
n
10M Full
n
10M Half
SMTP PORT
The port number of SMTP is set.
The default is “0”.
The default is “0”.
In this case, Port No. 25 is used.
If the port number of the SMTP server is other
than 25, make this setting.
than 25, make this setting.
Item
Set value range, remark
COMMAND
When [Send] button is clicked, the RS-232C
command entered to the edit box by the user
command entered to the edit box by the user
is sent to this machine.
The response of the command is displayed in
the lower section of the edit box.
the lower section of the edit box.
SYSTEM LOG
The system log file of this machine is
obtained.
obtained.
When the anchor is clicked, the file download
dialogue of the browser is displayed.
Follow the instructions of the dialogue.
Follow the instructions of the dialogue.
TEMPERATURE
LOG
LOG
The temperature log file of this machine is
obtained.
obtained.
When the anchor is clicked, the file download
dialogue of the browser is displayed. Follow
the instructions of the dialogue.
the instructions of the dialogue.
Click on the first or last page to see other PN-L802B (serv.man8) service manuals if exist.