CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 44
INTERRUPTION MODE (SHADOW: ON)
The wave sensor in the shadow OFF mode is as shown below. The interruption state of the sensor can be checked with the display.
When there is no interrupting substance.
Blue line : Interruption waveform
Red line  : Reference value
Orange line: Interruption mode detection level (dlvl_sh)
When there is an interrupting substance (Interrupting substance peripheral waveform)
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 45
2D IMAGES
When the 2D images check is executed, the 2D image obtained by the sensor is displayed as shown below.
There are default displays of line map (yellow line), first, peakseg, and last. When it is clicked on the 2D image display area, the display of line map,
etc, will disappear.
LED OFF
When LED OFF is checked, the infrared LED is turned OFF, and the sensor waveform becomes as shown in the figure below.
2D images display area
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 46
<SENSOR ADJUSTMENT>
When “(2) SENSOR CHECK AND ADJUSTMENT - 2” is selected, the parameter dialogue below is displayed.
3Refer to page 4 - 41  "(2) SENSOR CHECK AND ADJUSTMENT".
MEMO
n
When Sensor adjustment tool is started, it is automatically displayed only once.
Though there are tabs of [Common], [Captured], [Scope adjustment], [Touch sensitivity], [Lens correction value], [therm], and [offset correction]., only
[Common], [Captured], and [Scope adjustment] are used at the current stage. 
When replacing the PWB, be sure to execute the initial adjustment.
3Refer to page 4 - 50  "21. INITIAL ADJUSTMENT PROCEDURE".
COMMON TAB
NO.
Setting content
1
Captured interval
Time setting of the Captured interval 
(msec). 
The default value is 10, and the sam-
pling rate is 100 points/sec.
2
mlvl 
(minimum level)
The value greater than this in the range 
of first - last of the sensor waveform is 
required.
3
LED intensity
Setting of the LED light emitting 
strength.
1
2
3
Click to reflect the value. 
Check to make the dialogue half-transparent.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 47
CAPTURED TAB
SCOPE ADJUSTMENT TAB
When  4“Line Detect” of “(2) Sensor adjustment dialogue” is clicked,
the above 2 and 3 are automatically set to the optimum values.
NO.
Setting content
1
Gain
Gain of brightness. 
When this value is increased, the 
brightness is increased.
2
Offset
The value to make the brightness near 
zero when a finger or other interrupting 
substance is inserted to make a shade.
3
Exposure
Exposure time of the LED. 
When this value is increased, the radia-
tion time is increased, making the 
image brighter.
4
V-smoothing
Smoothing process with the upper and 
lower lines.
1
2
3
4
1
2
3
4
L side sensor setting
R side sensor setting
NO.
Setting content
1
first, last 
(Refer to the sen-
sor waveform.)
Coordinate calculation start position in 
the sensor waveform (first: left side), 
and coordinate calculation end position 
(last: right side)
2
vpos
Setting value to specify the center posi-
tion (overall) of the light belt in the 2D 
image.
3
shift 0 - 2
Offset value to set the center position 
(vpos reference) of each of first, last, 
and peakseg in the 2D image. (Shift0, 
shift1, and shift2 correspond to first, 
last, and peakseg respectively.) 
This setting value corresponds to the 
line map (yellow line) on the 2D image.
4
peakseg 
(Refer to the sen-
sor waveform.)
Sensor Scope folding position in the 
sensor waveform.
1
2
3
4
1
2
3
4
L side sensor setting
R side sensor setting