CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 48
TOUCH SENSITIVITY (REFERENCE)
This tab is used to set when the sensor unit is delivered.
LENS CORRECTION VALUE/THERM (REFERENCE)
Lens correction value tab settings are made when delivering the sensor
unit, and basically cannot be adjusted in the market.
For setting with [therm] tab, refer to the temperature compensation set-
ting which was automatically set in the sensor waveform dialogue. In
addition, the temperature compensation setting can be disabled.
NO.
Setting content
1
divl_sh
Interruption mode detection level. 
When this value is increased, detection 
level of the interruption mode is 
decreased.
2
hlvl
Half level offset.
1
2
1
2
No change allowed
No change allowed
L side sensor setting
R side sensor setting
When "type: 1,"  
the temperature 
compensation 
is valid.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 49
<X-Y PLOT>
When “(2) SENSOR CHECK AND ADJUSTMENT - 3” is selected, the X-Y plot dialogue is displayed as shown below. The drop-down menu at the
left upper of the dialogue allows selection of [Double-size scale], [Normal-size scale], [Reduction double-size scale], and [Reduction normal-size
scale].
3Refer to page 4 - 41  "(2) SENSOR CHECK AND ADJUSTMENT".
When each item is selected, the display is as shown below to allow checking the coordinates of interruption detection and its size.
Since the effective area of the PN-L802B is in the double-size scale display, there is no need to use the normal-size scale display which displays a
wider area than that. 
 
 
 
 
16384 resolution
16384 resolution
Right side
sensor position
Left side
sensor position
Interruption detection position
(The size varies according to
the interruption size.)
Reduction double
size scale
Reduction normal
size scale
Normal-size scale
Double-size scale
Double-size scale display area
Reduction
display
Reduction
display
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 50
21. INITIAL ADJUSTMENT PROCEDURE
21 - 1. ALL FLOWCHART
21 - 2. WORK PROCEDURE
1 ) Press [Sensor Adjustment] button of the service tool launcher to
boot the sensor adjustment tool on the PC.
2 ) Connect the mini USB (CN3) of the PN-L802B and the PC with the
USB cable C, and wait until initialization of the touch panel is com-
pleted.
3 ) Press [Connect] button.
START
Y
N
Y
N
END
Connection
touch panel
Waveform
abnormality?
Normal
completion?
Touch panel
connection cancel
Reflection tape mounting bracket condition, 
reflection tape check, Camera FFC check.
first/last/peakseg fine adjustment.
While watching the sensor waveform, put
the pen on the screen to execute the fine
adjustment of the start position, the end
position, and the corners in the lower side.
Adjust the optical axis shift after
completion of the adjustments of
first/last/peakseg.
The adjustment result of 1 to 4 are written
 into the EEPROM on the SIROKU PWB.
Flash writing
5
Scope
adjustment
2
Sensor optical 
axis initialization
3
If the operation is terminated without
writing, the adjustment result is not 
saved. 
Apply temperat
-ure compensa
-tion
4
Enable temperature compensation 
function.
Zero level of
light quantity
adjustment
1
Adjust the zero level of  light quantity 
with referring to the sensor waveform.
CAUTION
The mini USB connector in the touch
panel connected with the PC by a USB
cable is at the left side when viewed
from the back.
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L802B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 51
4 ) Press [Sensor adjust] button. After confirming connection, press
[Wave sonsor] button and [Parameter View Settings] button.
1 Zero level of light quantity adjustment
For the value of light quantity zero, execute the offset adjust-
ment.
3Refer to page 4 - 52  "21 - 3. ZERO LEVEL OF LIGHT QUAN-
TITY ADJUSTMENT".
2 Scope adjustment
Apply a pen to four points to perform the Scope adjustment.
3Refer to page 4 - 53  "21 - 4. DETAILED PROCEDURES OF
THE SCOPE ADJUSTMENT".
3 Sensor optical axis initialization
Press [Line Detect] button.
3Refer to page 4 - 59  "21 - 5. SENSOR OPTICAL AXIS INI-
TIALIZATION".
4 Apply temperature compensation
The temperature compensation function is enabled.
3Refer to page 4 - 59  "21 - 6. Apply temperature compensa-
tion".
5 Flash writing
Press [Flash write] button to write the set values of procedures
1 and 2 into the SIROKU PWB.
3Refer to page 4 - 59  "21 - 7. FLASH WRITING".
5 ) Press [Disconnect] button.
6 ) Disconnect the USB cable C (in the mini USB side).