N
Error display
The display shows the following message when no error occurred
in all the checks.
PWB Diagnostics
***** NO 
ERROR *****
If an error occurred, the display shows the check where the error
occurred.
PWB Diagnostics
D-RAM Check ERROR
The check where an error
occurred is displayed.
Serial I/O Check COM1 ERROR
Press the space bar to terminate the check, and the display will
return to the menu screen.
4-3. Radiation Measuring Diagnostics
This diagnostics is used to measure unnecessary radiation of the
ER-45X series and to measure radioactive magnetic field of CE-Mark.
The figure below shows the measuring system configuration. The
master machine includes the built-in options, the ER-A8RS and the
ER-04MB.
Fig. 4-3 Measuring system configuration
The display shows the following menu. The highlighted cursor is
moved with the cursor up key (
) and the cursor down key (
) of the
AT key. Move the cursor to the diagnostics item to be executed, then
press the Enter key, and the selected individual diagnostics program
will be executed. After completion of an individual diagnostics pro-
gram, the display returns to the menu screen. To exit from the diag-
nostics mode, press the Esc key, and the display will return to the
PWB diagnostics menu screen.
CE-Mark Measuring Diagnostics
 Master Machine 
 Satellite Machine
The following checks are performed continuously. To terminate the
test, press the Esc key, and the display will return to the menu screen.
Be sure to set the satellite machines before setting the master ma-
chine.
1) Master Machine Check Contents
When "Master Machine" is selected, the master machine performs the
following checks.
1
SRN transmission test
i.
Set the terminal NO. of the master machine to 100, and set
the terminal No. of satellite machine to 200.
ii.
Send the data in the following format to the satellite machine.
Test data format (1 packet: 256 byte)
iii.
Data sent back from the satellite machine is checked. If the
data is correct, the program goes to the next test.
If the data is not correct, send the data in procedure ii again to
the satellite machine. If data error occurs 3 times continu-
ously, the error message is displayed and the test is termi-
nated.
Display during SRN test 
Data Transmission Check (Master Machine)
Input Master Terminal Number
:
100
Input Satellite Terminal Number
:
200
Error message
Data Transmission Check (Master Machine)
Input Master Terminal Number
:
100
Input Satellite Terminal Number
:
200
********** SRN 
DATA 
ERROR 
!!! **********
2
RS-232 Loop Back Test
Loop back test is performed to I/O address 3F8H 
 3FFH. The test
procedures are as follows.
i.
The RTS signal is turned on/off to check that the CD and the
CTS signals operate normally.
ii.
The DTR signal is turned on/off to check that the DSR and the
RI signals operate normally.
iii.
Set the baud rate to 19200bps in asynchronous mode. Send
data of 256 bytes at 00H 
 FFH from the SD signal line. Data
received at the RD signal line is compared with the sent data.
If the both are identical, the program goes to the next test. If
not, data in procedure iii is sent again. If data error occurs 3
times continuously, the error message is displayed and the
test is terminated.
Display during printing
RS-232 COM1 Loop Back Check
Error message
RS-232 Loop Back Check
**********  RS-232 DATA ERROR !!!  **********
AT key
ER-A850/A880
ER-02WD
ER-A850/A880
Master machine
Satellite machine
X X
X X
A A
A A
A A
A A
A A
A A
256
255
254
5
4
3
2
1
Byte
XXXX
A A
: Sequence No.2bytes (0000H)
: Transmission data (AAH) x 254 bytes
– 25 –
3
LCD Display Check
"H" pattern. Characters "H" are displayed in 80 columns 
×
    25
lines. The last 35th line, however, shows 79 columns of "H." (In
actual, the screen shows only 25 lines. Check the rest of 10 lines
by scrolling.)
4
Drawer open
The drawer 1 solenoid is turned on and the following message is
displayed.
Drawer 1 Open Check
Tests 
1
 
 
4
 are repeated. Pressing the Esc key during test will
interrupt the test to return to the menu screen.
2) Satellite Machine Check Contents
When "Satellite Machine" is selected, the satellite machine performers
the following test.
1
SRN transmission test
i.
Set the terminal No. of the satellite machine to 200.
ii.
The satellite machine sends back data sent from the master
machine to the master machine. It repeats this operation.
Display during SRN transmission test
Data Transmission Check (Satellite Machine)
Input Satellite Terminal Number
:
200
Pressing the Esc key during test, the test is interrupted to return to
the menu screen.
4-4. Temperature Rise Test Diagnostics
This diagnostics is used to test temperature rise in the ER-45X series.
The table below shows the system configuration required from the
test.
The ER-45X includes two ER-A8RS’s and the ER-04MB as built-in
options.
Fig. 4-4 Temperature rise test system configuration
1) Temperature Rise Test Contents
1
Drawer open
The drawer 1 solenoid is turned on and the following message is
displayed.
Display during drawer test
Drawer 1 Open Check
2
RS-232 Loop Back Test
Loop back test is performed to I/O address 3F8H 
 3FFH. The test
procedures are as follows.
i.
The RTS signal is turned on/off to check that the CD and the
CTS signals operate normally.
ii.
The DTR signal is turned on/off to check that the DSR and the
RI signals operate normally.
iii.
Set the baud rate to 19200bps in asynchronous mode. Send
data of 256 bytes at 00H 
 FFH from the SD signal line. Data
received at the RD signal line is compared with the sent data.
If the both are identical, the program goes to the next test. If
not, data in procedure iii is sent again. If data error occurs 3
times continuously, the error message is displayed and the
test is terminated.
Display during printing
RS-232 COM1 Loop Back Check
Error message
RS-232 Loop Back Check
**********  RS-232 DATA ERROR !!!  **********
Tests 
1
 and 
2
 are repeated. The interval time between drawer ON
and the next drawer ON is 2.4 sec. Pressing the Esc key during
test will interrupt the test to return to the menu.
4-5. RAM Diagnostics
Same as 3-3 RAM Diagnostics.
4-6. ROM Diagnostics
Same as 3-4 ROM Diagnostics.
4-7. Real Time Clock & CMOS RAM Diagnostics
Same as 3-5 Real time clock & CMOS RAM Diagnostics.
4-8. POS Keyboard Diagnostics
Same as 3-6 POS Keyboard Diagnostics.
4-9. Clerk Key Diagnostics
Same as 3-7 Clerk Key Diagnostics.
4-10. Printer diagnostics
Same as 3-8 Printer Diagnostics.
AT key
ER-A850/A880
ER-02WD
– 26 –
4-11. Serial I/O Diagnostics
Same as 3-9 Serial I/O Diagnostics.
4-12. Liquid Crystal Display Diagnostics
Same as 3-10 Liquid Crystal Display Diagnostics.
4-13. Real Display diagnostics
Same as 3-11 Real Display Diagnostics.
4-14. SHARP Retail Network Diagnostics
Same as 3-12 SHARP Retail Network Diagnostics.
4-15. Magnetic Card Reader Diagnostics
Same as 3-13 Magnetic Card Reader Diagnostics.
4-16. System Switch Diagnostics
Same as 3-14 System Switch Diagnostics.
4-17. Drawer Diagnostics
Same as 3-15 Drawer Diagnostics.
5. Process Test Diagnostics
5-1. Execution of Diagnostics
Set the DIP switch of the ER-45X as shown in Fig. 5-1,  and supply
power to the ER-45X.
Fig. 5-1 DIP switch setting for diagnostic program
From the DOS prompt,  execute "DIAG.EXE" by entering  as follows
with the AT key.
 C>DIAG
"C>" is the DOS prompt.
The diagnostics program is initiated and the display shows the follow-
ing menu. The highlighted cursor is moved with the cursor up key (
)
and the cursor down key (
) of the AT key. Move the cursor to the
diagnostics item to be executed, then press the Enter key, and the
selected individual diagnostics program will be executed. After com-
pletion of an individual diagnostics program, the display returns to the
menu screen.
Press the Esc key to terminate the diagnostics.
ER-A880/A850 Production Diagnostics  V 1.0A
 Sequential Diagnostics 
 RAM Diagnostics
 ROM Diagnostics
 Real time clock & CMOS RAM Diagnostics
 POS Keyboard Diagnostics
 Clerk Key Diagnostics
 Serial I/O Diagnostics
 LCD (Liquid Crystal Display) Diagnostics
 System Switch Diagnostics
5-2. Sequential Diagnostics
This diagnostics is used to test the ER-45X in the production process.
The figure below shows the system configuration required for the test.
The ER-45X includes the ER-A8RS connected with the RS-232  loop
back connector.
Fig. 5-2 Sequential check system configuration
The following checks are performed continuously. (Even if an error
occurs, the checks are performed.)
To terminate the test midway, press the Esc key, and the display will
return to the menu screen.
1) Sequential Check
1
D-RAM Check
The check contents and the display are the same as "3-3. 1)
D-RAM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
2
Standard RAM Disk Check
The check contents and the display are the same as "3-3. 2)
Standard RAM Disk Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
3
System ROM Check
The check contents and the display are the same as "3-4. 1)
System ROM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, press the space bar to go to the
next check.
4
BIOS ROM Check
The check contents and the display are the same as "3-4. 2) BIOS
ROM Check."
After completion of this check, press the space bar to go to the
next check.
5
Real time clock Check 
The check contents and the display are the same as "3-5. 1) Real
time clock Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
6
CMOS RAM Check
The check contents and the display are the same as "3-5. 2)
CMOS RAM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
7
POS Keyboard Check
This diagnostics is used to check the keyboard input of the ER-
A850/A880.
The key layout of each of the ER-A850/A880 is displayed on the
LCD screen. Press keys accordingly to perform input check.
To identify the ER-A850 and the ER-A880, I/O address 3F0H is
read. If the most significant bit is "1," it is judged as the ER-A880.
If "0," as the ER-A850.
In the case of the ER-A880, the touch panel key layout is dis-
played on the LCD screen; and in the case of the ER-A850, the
flat key layout is displayed.
SW1
ON
OFF
OFF
OFF
OFF
SW2
SW3
SW4
OFF
AT key
ER-A850/A880
– 27 –
ER-A880 Keyboard Check
Rectangular frames (10 
×
 25) are displayed on the LCD screen
according to the touch panel sensors positions. Press the touch
panel, and the catch buzzer will sound and the corresponding
frame on the LCD will be highlighted (black).  When all the
frames are highlighted, the program goes to the next check.
Key depression procedure
ER-A850 Keyboard Check
Rectangular frames (13 
×
 12) are displayed on the LCD screen
according to the keyboard layout. Press the keyboard, and the
catch buzzer will sound and the corresponding frame on the
LCD will be highlighted (black). When all the frames are high-
lighted, the program goes to the next check.
Key depression procedure
8
Clerk Key Check
Insert the clerk keys according to the display, The sequence of key
insertion is 1, 2, 4, 8, 16, 32. If the proper key  is inserted, the
message to urge to insert the next key is displayed.
After completion of key  32 check, the program goes to the next
check.
Clerk Key Check
Insert 1 Key
Displayed in sequence of 1, 2, 4, 8, 16, 32.
9
COM3 Check
The check contents and the display are the same as "3-9. 3)
COM3 Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
F
Liquid Crystal Display Check
The check contents and the display are the same as "3-10. 1)
Liquid Crystal Display Check."
After completion of the check, press the space bat to go to the
next check.
G
Error message
If there is no error in all the checks, the following message is
displayed.
PWB Diagnostics
***** NO 
ERROR *****
When an error occurred, the check where the error occurred is
displayed as shown below.
Production Diagnostics
D-RAM Check ERROR
The check where an error
occurred is displayed.
Serial I/O Check COM3 ERROR
Press the space bar to terminate the check and return to the menu
screen.
5-3. RAM Diagnostics
Same as 3-3 RAM Diagnostics.
5-4. ROM Diagnostics
Same as 3-4. ROM diagnostics.
5-5. Real Time Clock & CMOS RAM Diagnostics
Same as 3-5. Real Time Clock & CMOS RAM Diagnostics.
5-6. POS Keyboard Diagnostics
Same as POS Keyboard Diagnostics.
5-7. Clerk Key Diagnostics
Same as 3-7 Clerk Key Diagnostics.
5-8. Serial I/O Port diagnostics
Same as 3-9 Serial I/O Diagnostics.
5-9. Liquid Crystal Display Diagnostics
Same as 3-10 Liquid Crystal Display Diagnostics.
5-10. System Switch Diagnostics
Same as 3-14 System Switch Diagnostics.
START
END
START
END
– 28 –