DOWNLOAD Sharp ER-A850 (serv.man2) Service Manual ↓ Size: 1.18 MB | Pages: 92 in PDF or view online for FREE

Model
ER-A850 (serv.man2)
Pages
92
Size
1.18 MB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / ERA850 880 Service Manual
File
er-a850-sm2.pdf
Date

Sharp ER-A850 (serv.man2) Service Manual ▷ View online

3
Exiting
Pressing the Esc key will exit from this check mode. When exiting,
perform resetting of the SRN software in the PSC.
4) Data Transmission Check
This is to check data transmission in an actually configured system.
The system is composed of one master machine and max. 15 satellite
machines.
Precautions for starting the test
To test a unit where SRN setting has already been made, cancel
the SRN setting before execution of this test.
To perform this test in an actually configured system, disconnect
the SRN cables of the units which are not subject to the test, or
cancel the SRN setting. If this test is performed with the SRN
setting active, data may be destroyed.
Be sure to cancel the SRN setting of all the units in the system
before setting the data transmission check.
Setting of the satellite machines must be performed in advance to
setting of the master machine.
1
Setting procedure
i.
Satellite machine setting
Select "Data Transmission Check (Satellite Machine)" in the
menu. The following display will be shown.
Data Transmission Check (Satellite Machine)
Input Terminal number
:
Type the terminal No. (3-digit number of 000 
 254) of the test
machine and press the Enter key. The display below will be
shown.
Data Transmission Check (Satellite Machine)
Input Terminal Number
: XXX —— Shows the entered
terminal No.
Data Sequence Number : 0000
ii.
Master machine setting
Select "Data Transmission Check (Satellite Machine)" in the
menu. The following display will be shown.
Data Transmission Check (Master Machine)
Input Master Terminal number
:
Type the terminal No. (3-digit number of 000 
 254) of the test
machine and press the Enter key. The display below will be
shown.
Data Transmission Check (Master Machine)
Input Master Terminal Number   : XXX — Shows the entered
terminal No.
Input Satellite Terminal Number  :
Type the terminal No. (3-digit number of 000 
 254)  of  the
satellite machine  which is connected to the master machine
to be tested. The display below will be shown.
Data Transmission Check (Master Machine)
Input Master Terminal Number   : XXX
Input Satellite Terminal Number  : XXX — Shows the entered
terminal No.
Input Satellite Terminal Number  :
If two or more satellite machines are connected to the master
machine, type the all the terminal Nos. (3-digit numbers of 000
 254) of the satellite machines as well and press the Enter
key.
After setting all the terminal Nos., press the Enter key, and the
display below will be shown.
Be careful not to use a same number to different machines
(either the master machine or the satellite machines).
Data Transmission Check (Master Machine)
Input Master Terminal Number   : XXX
Input Satellite Terminal Number  : XXX
Input Satellite Terminal Number  :
Data Sequence Number
  : 0000
With the above setting, data transmission is started between
the master machine and the satellite machines.
2
Check contents
i.
The test data composed of a 2-byte sequence number and
254-byte AAH data in the format shown below is sent from the
master machine to the satellite machines. The master ma-
chines display the sequence number.
Test data format (1 packet: 256 bytes)
ii.
The satellite machine sends back the received data to the
master machine, and shows the received sequence No.
iii.
After receiving the data, the master machine checks the se-
quence No. and 254-byte AAH data. If there is any error, the
master machine displays the error code and terminates the
test.
If two or more satellite machines are connected, repeat proce-
dures i and ii. When data transmission with all the satellite
machines is normal, the master machine increments the se-
quence number.
Procedures from i to iii are repeated.
XX
XX
AA
AA
AA
AA
AA
AA
256
255
254
5
4
3
2
1
Byte
XXXX
AA
: Sequence No. (2byte: 4digits of binary decimal numbers)
: Transmission data (AAH) x 254 bytes
– 21 –
3
Error display
Data Transmission Check (Master Machine)
Input Master Terminal Number : XXX
Input Satellite Terminal Number : XXX
Input Satellite Terminal Number :
Data Sequence Number
: XXXX
IRC Error
: XX — Shows the error code.
The table below shows the error codes.
01
Command abnormality (Except for during transmission)
02
No data received.
03
Received size present.
Received data remained.
04
Remote station not ready (in sending)
"NRDY" is sent back because the remote station is not ready
for reception.
05
Reception buffer full (in sending)
The controller reception buffer of the remote machine is full.
06
Resend error (in sending)
Retry over (5 times) when no response.
07
Collision error (in sending)
When an collision occurred in data transmission, retry over
(16 times) at re-collision after a random time (0 
 255ms).
08
Line busy time out
Transmission cannot be made by multi-station
communication to cause time out in data send wait time.
09
Reception size over (in receiving)
The reception buffer size is insufficient.
0A
Hardware error
Interface abnormality (No SRN interface or abnormality in
SRN controller)
3
Exiting
Pressing the Esc key will exit from this check mode. When exiting,
reset the SRN software in PSC.
3-13. Magnetic Card Reader Diagnostics
This diagnostics is used to perform read test of the ER-A8MR (op-
tion).
The test program reads the magnetic card of ISO 7811/1 
 5  stand-
ards, and displays the data.
Pressing the Esc key will exit from this check mode to return to the
service-man diagnostics menu.
1) Magnetic Card Reader Check
1
Check contents
The test program reads tracks 1 and 2 of the magnetic card of ISO
7811/1 
 5 standards, and displays the data in ASCII code.
2
Display
MCR (Magnetic Card Reader) Check
TRACK 1
:
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
TRACK 2
:
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXX: Shows the data read by the MCR. In case of an error, the
error codes are displayed as shown below.
Magnetic Card Reader Check
TRACK 1  : BUFFER EMPTY — Displayed when TRACK 1
EMPTY code is sent back.
TRACK 1  : MCR ERROR
— Displayed when TRACK 1
ERROR code is sent back.
TRACK 2  : BUFFER EMPTY — Displayed when TRACK 2
EMPTY code is sent back.
TRACK 2  : MCR ERROR
— Displayed when TRACK 2
ERROR code is sent back.
3
Exiting
Pressing the Esc key will exit from this check mode.
3-14. System Switch Diagnostics
This diagnostics is used to display the main PWB system switch
information.
Pressing the Esc key will exit from this check mode to return to the
service-man diagnostics menu.
1) System Switch Check
1
Check contents
I/O address 3F0H is read at every 100ms to display the values at
bit 3 
 7. The table below shows the relationship between the bit
and the SW.
Bit
7
6
5
4
3
2
1
0
3F0H
SW5
SW4
SW3
SW2
SW1
X
X
X
2
Display
System Switch Check
SW5
SW4
SW3
SW2
SW1
X
X
X
X
X
"X" shows the data of each SW. If the bit data is "1," "1" is displayed.
If the bit data is "0," "0" is displayed.
3
Exiting 
Pressing the Esc key will exit from this check mode.
3-15. Drawer Diagnostics
This diagnostics is used to check drawer open and sensors.
The display shows the following menu. The highlighted cursor is
moved with the cursor up key (
) and the cursor down key (
) of the
AT key. Move the cursor to the diagnostics item to be executed, then
press the Enter key, and the selected individual diagnostics program
will be executed. After completion of an individual diagnostics pro-
gram, the display returns to the menu screen. To exit from the diag-
nostics mode, press the Esc key, and the display will return to the
service-man diagnostics menu screen.
Drawer Diagnostics
 Drawer 1 Check 
 Drawer 2 Check
 Drawer 3 Check
 Drawer 4 Check
– 22 –
1) Drawer 1 Check
1
Check contents
The solenoid of drawer 1 is turned on, and the drawer open sen-
sor value is sensed at every 100ms, and the state is displayed.
2
Display
Drawer 1 Check
Drawer Open Sensor
:
OPEN (or CLOSE)
3
Exiting 
Pressing the Esc key will exit from this check mode.
2) Drawer 2 Check
1
Check contents
The solenoid of drawer 2 is turned on, and the drawer open sen-
sor value is sensed at every 100ms, and the state is displayed.
The display and exiting procedure are the same as those of
Drawer 1 Check.
3) Drawer 3 Check 
1
Check contents
The solenoid of drawer 3 is turned on, and the drawer open sen-
sor value is sensed at every 100ms, and the state is displayed.
The display and exiting procedure are the same as those of
Drawer 1 Check.
4) Drawer 4 Check
1
Check contents
The solenoid of drawer 3 is turned on, and the drawer open sen-
sor value is sensed at every 100ms, and the state is displayed.
The display and exiting procedure are the same as those of
Drawer 1 Check.
4. Board Test Diagnostics
4-1. Execution of Diagnostics
Set the DIP switch of the ER-45X as shown in Fig. 4-1,  and turn on
the power of the ER-45X.
Fig. 4-1 DIP switch setting in execution of diagnostics program
From the DOS prompt,  execute "DIAG.EXE" by entering  as follows
with the AT key.
 C>DIAG
"C>" is the DOS prompt.
The diagnostics program is initiated and the display shows the follow-
ing menu. The highlighted cursor is moved with the cursor up key (
)
and the cursor down key (
) of the AT key. Move the cursor to the
diagnostics item to be executed, then press the Enter key, and the
selected individual diagnostics program will be executed. After com-
pletion of an individual diagnostics program, the display returns to the
menu screen.
Press the Esc key to terminate the diagnostics.
ER-A880/A850 PWB Diagnostics  V 1.0A
 Sequential Diagnostics 
 Radiation Measuring Diagnostics
 Temperature Rise Test Diagnostics
 RAM Diagnostics
 ROM Diagnostics
 Real time clock & CMOS RAM Diagnostics
 POS Keyboard Diagnostics
 Clerk Key Diagnostics
 Printer Diagnostics
 Serial I/O Diagnostics
 LCD (Liquid Crystal Display) Diagnostics
 Rear Display Diagnostics
 SRN (SHARP Retail Network) Diagnostics
 MCR (Magnetic Card Reader) Diagnostics
 System Switch Diagnostics
 Drawer Diagnostics
4-2. Sequential Diagnostics
This diagnostics is used to test the main PWB unit of the EX-45X
series. The figure below shows the system configuration required for
the test.
Fig. 4-2 Sequential check system configuration
The following checks are performed continuously. (The check proce-
dures are continued even when an error occurs.)
To terminate the test midway, press the Esc key, and the display will
return to the menu screen.
1) Sequential Check
1
D-RAM Check
The check contents and the display are the same as those of "3-3.
1) D-RAM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
2
Standard RAM Disk Check
The check contents and the display are the same as "3-3. 2)
Standard RAM Disk Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
SW1
ON
OFF
OFF
OFF
OFF
SW2
SW3
SW4
OFF
Invertor unit
ER-A880:
ER-A850:
640 x 480
LCD unit
640 x 200
LCD unit
Power
source
Main PWB
ER-04MB
Expantion slot
ER-A8RS
AT key board
IOC PWB
One-hole
clerk
SRN terminal
resistor
ER-A8DP
RS-232 loop
connector
Lock unit
– 23 –
3
ER-04MB Check
The check contents and the display are the same as "3-3. 4)
ER-04MB Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
4
System ROM Check
The check contents and the display are the same as "3-4. 1)
System ROM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
5
BIOS ROM Check
The check contents and the display are the same as "3-4. 2) BIOS
ROM Check."
After completion of this check, press the space bar to go to the
next check.
6
Real time clock Check
The check contents and the display are the same as "3-5. 1) Real
time clock Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
7
CMOS RAM Check
The check contents and the display are the same as "3-5. 2)
CMOS RAM Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
8
Clerk Key Check
Insert Clerk key 1 key according to the display indication. When
the correct key is inserted, the program goes to the next step.
Clerk Key Check
Insert 1 Key
9
COM1 Check 
The check contents and the display are the same as "3-9. 1)
COM1 Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
F
COM2 Check
The check contents and the display are the same as "3-9. 2)
COM2 Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
G
COM3 check
The check contents and the display are the same as "3-9 3)
COM3 Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
H
Liquid Crystal Display Check
The check contents and the display are the same as "3-10. 1)
Liquid Crystal Display Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, press the space bar to go to the
next check.
I
Rear Display Check
The check contents and the display are the same as "3-11. 1)
Rear Display Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, press the scape bar to go to the
next check.
J
SRN Self Check
The check contents and the display are the same as "3-12. 1)
SRN Self Check."
In case of an error, the error content is recorded. (In order to
display the error content after completion of the diagnostics.)
After completion of this check, the next check is performed.
K
System Switch Check
I/O address 3F0H is read to display the values at bit 3 
 7.  The
table below shows the relationship between the bits and SW. If
bits 3 
 6 are not "0," the display shows "ERROR." In case of an
error, the error content is recorded. (In order to display the error
content after completion of the diagnostics.)
Bit
7
6
5
4
3
2
1
0
3F0H
SW5
SW4
SW3
SW2
SW1
X
X
X
System Switch Diagnostics 
SW5 SW4 SW3 SW2 SW1
X
X
X
X
X
System Switch Error ——— Displayed in case of an error.
After completion of this check, press the space bar to go to the
next check.
L
Drawer 1 Check
The drawer open sensor is sensed. If the drawer is open, an error
message is displayed.
Then the drawer 1 solenoid is turned on. After 200ms, the drawer
open sensor is sensed again. If the drawer is closed, an error
message is displayed.
Drawer 1 Check
CLOSE Check
:
PASS (or ERROR)
OPEN Check
:
PASS (or ERROR)
After completion of this check, the next check is performed.
M
Drawer 2 Check
The drawer open sensor is sensed. If the drawer is open, an error
message is displayed.
Then the drawer 2 solenoid is turned on. After 200ms, the drawer
open sensor is sensed again. If the drawer is closed, an error
message is displayed.
Drawer 2 Check
CLOSE Check
:
PASS (or ERROR)
OPEN Check
:
PASS (or ERROR)
After completion of this check, the next check is performed.
– 24 –
Page of 92
Display