DOWNLOAD Sharp AH-X08 (serv.man4) Service Manual ↓ Size: 113.74 KB | Pages: 5 in PDF or view online for FREE

Model
AH-X08 (serv.man4)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
113.74 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / Wiring diagrams
File
ah-x08-sm4.pdf
Date

Sharp AH-X08 (serv.man4) Service Manual ▷ View online

6
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
WIRING DIAGRAMS
Figure W-1. Wiring Diagram for AH-X08CR/X10CR/X13CR and AY-X08CR/X10CR/X13CR
BROWN
RY1
In
Out
CB612-1
10
7
8
6
Temperature
Indicator
Blinking No.
Abnormal contents
AC overcurrent
 Abnormal AC current
WPE1
250V
3A
INDOOR UNIT
UNIT
TO
UNIT
CORD
Power factor module(AF1) error
13
Overheat of the power module(IPM) or
short circuit of the power module(IPM) heat-sink thermistor
Open circuit of the power module(IPM) heat-sink thermistor
Rotation error of the compressor
OUTDOOR UNIT
N
1
2
TERMINAL BOARD
CONTROL BOARD UNIT
POWER
SUPPLY
TERMINAL BOARD 2
SINGLE
PHASE
N
1
2
CONTROL
BOARD
UNIT
M
M
FAN MOTOR
COMPRESSOR
N
1
TERMINAL BOARD 1
M
M
LOUVER
(LOWER)
SERIAL
SIGNAL
CIRCUIT
BLUE
BLUE
BLACK
S
RED
N
INTERNAL
THERMAL
FUSE
RECEIVER
BOARD UNIT
R.P.M.
SIGNAL
FAN MOTOR
CAPACITOR
430V 2.0
µ
F
FAN MOTOR
LOUVER
(UPPER)
1
3
TH1
5
CN1
BCN1
BCN3
BCN2
CN2
CN3
TH2
YELLOW
ORANGE
CN6
CN7
DISPLAY
BOARD
UNIT
CN101
CN102
ROOM TEMP.
THERMISTOR
PIPE TEMP.
THERMISTOR
GREEN-YELLOW
TRANS1
SSR1
1
3
4
2
RED
BLUE
BLACK
C1
LED INDICATION FOR SELF-DIAGNOSIS
5
2
3
1
14
17
18
19
Short circuit of the outdoor thermistor
Overheat of the compressor
Open circuit of the outdoor thermistor
Power module(IPM) abnormality
Open circuit of serial signal line
Abnormal fan motor of indoor unit
Short circuit of serial signal line
CB612-2
<Indication of the abnormal condition>
LED indicator will blink,if the set
is in abnormal condition.
7
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
Figure W-2. Wiring Diagram for AE-X08CR/X10CR
+
-
+
-
N
1
2
INDOOR UNIT
TERMINAL
BOARD
CONTROL
BOARD
UNIT
POWER
SUPPLY
FAN
MOTOR
TERMINAL BOARD
UNIT TO UNIT CORD
SINGLE PHASE
220-240V 50Hz
BL
T2
BR
T3
RE
FC4
BULK HEAD
RE
T1
WPE1
C1
C2
C3
C4
C33
C34
15A
250V
SA1
RY1
T4
BCN11
CT1
The voltage is high at C8 (electronic capacitors) on outdoor unit.
For mentenance discharge at C8 to prevent electric shock.
In case that WPE101 has been fused, the voltage is kept high at C8.
CAUTION
BK
:BLACK          
RE
:RED                     YE
:YELLOW
BL
:BLUE             WH
:WHITE                G:GREEN
BR
:BROWN         
OR
:ORANGE
GR
:GRAY            G
(Y
):
GREEN
-YELLOW
BL
GR
G
(Y
)
G
(Y
)
FAN
MOTOR
BL
PTC
MRY1
IN
OUT
T6
T5
BK
TP
TN
YE
C8
OUTDOOR UNIT
POWER
TRANSISTOR
MODULE  
(QM101
)
TU
TV
TW
RE
WH
OR
COMPRESSOR
THERMISTOR
PIPE TEMP.
THERMISTOR
OUTDOOR
TEMP.
THERMISTOR
COMP. TEMP.
CN8
TH2
TH1
TH3
RE
OR
G
3
1
5
LED INDICATION OF SELF-DIAGNOSIS
ON OUTDOOR UNIT
LED BLINKING
LED turns on
Slow flashing 
(1 time for 2 seconds
)
Quick flashing 
(3 times for 2 seconds
)
Example: NO.2  Overheat of the compressor
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
CB565
1
2
3
4
10
NO.
LED indication pattern
Mulfunction part or abnormal condition
Normal
Abnormal signal line
Overheat of the compressor
DC overcurrent of the power module 
(QM101
Short circuit of the thermistor
7
8
6
NO.
LED indication pattern
Mulfunction part or abnormal condition
Open circuit of the thermistor
AC overcurrent
AC abnormal current
BK
1
2
3
4
5
6
NR1
NR2
CNR1
N
1
2
L3
L4
WPE3
3A
250V
CN3
CONTROL BOARD UNIT
DIODE BRIDGE
DB1
BL
C5
WPE101
20A
250V
OR
FC1
C10
C
AM
CONTROL
BOX
FAN MOTOR
CAPACITOR
1.5
µ
F 450V
C31
+
-
L1
WH
C8:1000
µ
F  420V
BL
~
~
9
Power factor module(AF1) error
S
R
C(T)
FC5
AF1
L-
L+
I-
I+
ACTIVE
FILTER
O-
O+
WH
YE
BR
FC2
3
1
RY2
CNR2
4-WAY
VALVE
5
11
Overheat of the power module or
short circuit of the heat-sink thermistor
Open circuit of the heat-sink thermistor
Rotation error of the compressor
C36
C35
C37
C38
BK
1
3
THERMISTOR
HEAT-SINK
TEMP.
CN7
4
1
YE
BL
CN12
CN13
BCN2
CN101
CN102
CN6
2
4
6
RE
WH
OR
POWER
TRANSISTOR
 UNIT
NO.3  DC overcurrent of the power module 
(QM101
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
0.6sec
0.6sec
x 2times
x 3times
x 4times
x 5times
x 6times
x 7times
x 9times
x 11times
x 13times
x 14times
This circuit
is removed
about cooling
only models
CN4
8
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
Figure W-3. Wiring Diagram for AE-X13CR
+
-
+
-
N
1
2
INDOOR UNIT
TERMINAL
BOARD
CONTROL
BOARD
UNIT
POWER
SUPPLY
FAN
MOTOR
TERMINAL BOARD
UNIT TO UNIT CORD
SINGLE PHASE
220-240V 50Hz
BL
T2
BR
T3
RE
FC4
BULK HEAD
RE
T1
WPE1
C1
C2
C3
C4
C33
C34
20A
250V
SA1
RY1
T4
BCN11
CT1
The voltage is high at C8 (electronic capacitors) on outdoor unit.
For mentenance discharge at C8 to prevent electric shock.
In case that WPE101 has been fused, the voltage is kept high at C8.
CAUTION
BK
:BLACK          
RE
:RED                     YE
:YELLOW
BL
:BLUE             WH
:WHITE                G:GREEN
BR
:BROWN         
OR
:ORANGE
GR
:GRAY            G
(Y
):
GREEN
-YELLOW
BL
GR
G
(Y
)
G
(Y
)
FAN
MOTOR
BL
PTC
MRY1
IN
OUT
T6
T5
BK
TP
TN
YE
C8
OUTDOOR UNIT
POWER
TRANSISTOR
MODULE  
(QM101
)
TU
TV
TW
RE
WH
OR
COMPRESSOR
THERMISTOR
PIPE TEMP.
THERMISTOR
OUTDOOR
TEMP.
THERMISTOR
COMP. TEMP.
CN8
TH2
TH1
TH3
RE
OR
G
3
1
5
LED INDICATION OF SELF-DIAGNOSIS
ON OUTDOOR UNIT
LED BLINKING
LED turns on
Slow flashing 
(1 time for 2 seconds
)
Quick flashing 
(3 times for 2 seconds
)
Example: NO.2  Overheat of the compressor
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
CB566
1
2
3
4
10
NO.
LED indication pattern
Mulfunction part or abnormal condition
Normal
Abnormal signal line
Overheat of the compressor
DC overcurrent of the power module 
(QM101
Short circuit of the thermistor
7
8
6
NO.
LED indication pattern
Mulfunction part or abnormal condition
Open circuit of the thermistor
AC overcurrent
AC abnormal current
BK
1
2
3
4
5
6
NR1
NR2
CNR1
N
1
2
L3
L4
WPE3
3A
250V
CN3
CONTROL BOARD UNIT
DIODE BRIDGE
DB1
BL
C5
WPE101
20A
250V
OR
FC1
C10
C
AM
CONTROL
BOX
FAN MOTOR
CAPACITOR
2.0
µ
F 450V
C31
+
-
L1
WH
C8:1300
µ
F  420V
BL
~
~
9
Power factor module(AF1) error
S
R
C(T)
FC5
AF1
L
-
L
+
I
-
I
+
ACTIVE
FILTER
O
-
O
+
WH
YE
BR
FC2
3
1
RY2
CNR2
4-WAY
VALVE
5
11
Overheat of the power module or
short circuit of the heat-sink thermistor
Open circuit of the heat-sink thermistor
Rotation error of the compressor
C36
C35
C37
C38
BK
1
3
THERMISTOR
HEAT-SINK
TEMP.
CN7
4
1
YE
BL
CN12
CN13
BCN2
CN101
CN102
CN6
2
4
6
RE
WH
OR
POWER
TRANSISTOR
 UNIT
NO.3  DC overcurrent of the power module 
(QM101
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
0.6sec
0.6sec
x 2times
x 3times
x 4times
x 5times
x 6times
x 7times
x 9times
x 11times
x 13times
x 14times
This circuit
is removed
about cooling
only models
CN4
9
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
Figure W-4. Wiring Diagram for AU-X08CR/X10CR
+
-
+
-
N
1
2
INDOOR UNIT
TERMINAL
BOARD
CONTROL
BOARD
UNIT
POWER
SUPPLY
FAN
MOTOR
TERMINAL BOARD
UNIT TO UNIT CORD
SINGLE PHASE
220-240V 50Hz
BL
T2
BR
T3
RE
FC4
BULK HEAD
RE
T1
WPE1
C1
C2
C3
C4
C33
C34
15A
250V
SA1
RY1
T4
BCN11
CT1
The voltage is high at C8 (electronic capacitors) on outdoor unit.
For mentenance discharge at C8 to prevent electric shock.
In case that WPE101 has been fused, the voltage is kept high at C8.
CAUTION
BK
:BLACK          
RE
:RED                     YE
:YELLOW
BL
:BLUE             WH
:WHITE                G:GREEN
BR
:BROWN         
OR
:ORANGE
GR
:GRAY            G
(Y
):
GREEN
-YELLOW
BL
GR
G
(Y
)
G
(Y
)
FAN
MOTOR
BL
PTC
MRY1
IN
OUT
T6
T5
BK
TP
TN
YE
C8
OUTDOOR UNIT
POWER
TRANSISTOR
MODULE  
(QM101
)
TU
TV
TW
RE
WH
OR
COMPRESSOR
THERMISTOR
PIPE TEMP.
THERMISTOR
OUTDOOR
TEMP.
THERMISTOR
COMP. TEMP.
CN8
TH2
TH1
TH3
RE
OR
G
3
1
5
LED INDICATION OF SELF-DIAGNOSIS
ON OUTDOOR UNIT
LED BLINKING
LED turns on
Slow flashing 
(1 time for 2 seconds
)
Quick flashing 
(3 times for 2 seconds
)
Example: NO.2  Overheat of the compressor
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
CB567
1
2
3
4
10
NO.
LED indication pattern
Mulfunction part or abnormal condition
Normal
Abnormal signal line
Overheat of the compressor
DC overcurrent of the power module 
(QM101
Short circuit of the thermistor
7
8
6
NO.
LED indication pattern
Mulfunction part or abnormal condition
Open circuit of the thermistor
AC overcurrent
AC abnormal current
BK
1
2
3
4
5
6
NR1
NR2
CNR1
N
1
2
L3
L4
WPE3
3A
250V
CN3
CONTROL BOARD UNIT
DIODE BRIDGE
DB1
BL
C5
WPE101
20A
250V
OR
FC1
C10
C
AM
CONTROL
BOX
FAN MOTOR
CAPACITOR
1.5
µ
F 450V
C31
+
-
L1
WH
C8:1000
µ
F  420V
BL
~
~
9
Power factor module(AF1) error
S
R
C(T)
FC5
AF1
L
-
L
+
I
-
I
+
ACTIVE
FILTER
O
-
O
+
WH
YE
BR
FC2
5
11
Overheat of the power module or
short circuit of the heat-sink thermistor
Open circuit of the heat-sink thermistor
Rotation error of the compressor
C36
C35
C37
C38
BK
1
3
THERMISTOR
HEAT-SINK
TEMP.
CN7
4
1
YE
BL
CN12
CN13
BCN2
CN101
CN102
CN6
2
4
6
RE
WH
OR
POWER
TRANSISTOR
 UNIT
NO.3  DC overcurrent of the power module 
(QM101
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
0.6sec
0.6sec
x 2times
x 3times
x 4times
x 5times
x 6times
x 7times
x 9times
x 11times
x 13times
x 14times
Page of 5
Display

Sharp AH-X08 (serv.man4) Service Manual ▷ Download

  • DOWNLOAD Sharp AH-X08 (serv.man4) Service Manual ↓ Size: 113.74 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AH-X08 (serv.man4) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AH-X08 (serv.man4) Air Conditioner. Information contained in Sharp AH-X08 (serv.man4) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.