DOWNLOAD Sharp UP-800 (serv.man32) Service Manual ↓ Size: 5.14 MB | Pages: 68 in PDF or view online for FREE

Model
UP-800 (serv.man32)
Pages
68
Size
5.14 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR / UP-800 In-Line (IRC) Instruction Manual
File
up-800-sm32.pdf
Date

Sharp UP-800 (serv.man32) User Manual / Operation Manual ▷ View online

31
OPXZ X1/Z1 X2/Z2
Report type
Description
Operating modes
Required data/Remarks
All clerk report
Individual clerk report
All cashier report
Individual cashier report
Hourly report (by specified range)
Hourly report (all)
Daily net report
GLU report
GLU report by clerk
Balance report
Customer ordering report
Stacked report 1
Stacked report 2
Electronic journal
Only for the individual clerk file system
Only for the individual clerk file system
Only for the clerk + cashier system
Only for the clerk + cashier system
Time range
GLU code
(The range can be specified by 
entering start and end codes.) 
Only for the individual GLU file system
Only for the individual GLU file system
Customer ordering code
(The range can be specified by 
entering start and end codes.)
-
X,Z
-
X,Z
-
-
-
-
-
-
-
-
X,Z
X1,Z1
X1,Z1
X1,Z1
X1,Z1
X1
X1,Z1
-
X1,Z1
X1,Z1
X1
-
X1,Z1
X1,Z1
X2,Z2
X2,Z2
X2,Z2
X2,Z2
-
-
X2,Z2
-
-
X2
X2,Z2
X2,Z2
-
<PERSONNEL>
ALL CLERK
IND. CLERK
ALL CASHIER
IND. CASHIER
<OTHERS>
HOURLY
DAILY NET
GLU
GLU BY CLERK
BALANCE
CUSTOMER 
ORDERING
STACKED REPORT
E. JOURNAL
32
In a system which has no save file and has been programmed so as to automatically lock the satellites after
resetting when general resetting, hourly resetting, cashier resetting or daily net resetting report is taken, the
data in the satellites concerned is not cleared. In this case, the satellites will be locked after resetting, and
any entry will not be allowed in the REG/MGR mode there.
Generation of the same resetting report in the locked state will print a copy symbol on the report.
The satellites can be unlocked by generating a consolidated resetting report at the master, or by manual
clearing of the sales memories of the satellites.
Your dealer can program whether or not to have save files, and whether or not to lock the satellites. For
details, consult your local authorized SHARP dealer.
4. Resetting reports in a system with no save file
33
As stated earlier (see page 8), there are two systems for collecting clerk sales data: a centralized system
and an individual system.
(1) Centralized clerk file system
In this system, the transaction data on a clerk in each satellite will be transmitted to the master each
time the clerk signs off. You cannot generate an individual clerk report for each satellite. At the master,
you can generate full and individual clerk consolidated reports.
At each satellite, you can generate individual clerk consolidated reports.
If resetting operation for a consolidated individual clerk Z report is made at a satellite where a clerk is
signed on, the data on transactions being handled by the clerk or cashier is also added and printed
out.
If a consolidated full clerk Z report is taken at the master while a clerk signs on at a satellite, that
clerk’s sales data are excluded from the report and resetting operation for the clerk can not be made.
Full clerk report sample in the centralized clerk file system (master)
For detailed information on report items, see the UP-800F/UP-810F Instruction Manual.
NOTE
000123  #0107  22/07/2008                   19:03 [0001]
CLERK0001
         Z1
CLERK STOP
ALL CLERK
CLK#0001
CLERK0001     
ORDER TL
115.25
CLK#0002
CLERK0002     
ORDER TL
63.75
CLERK START
Machine no.
Consecutive no.
Date
Report type
Clerk code
Clerk name
Data on clerk #0001
Report mode
Data on clerk #0002
(If the report is taken with clerk #0002 signed on at a 
satellite, the data on the clerk is not printed.)
Reset counter
Time
5. Clerk report
34
(2) Individual clerk file system
In this system, you can generate full or individual clerk consolidated X or Z reports at the master only.
At each machine, you can generate an individual X or Z report on transactions made by an individual
clerk or clerks assigned to the machine.
If the system has no save file, the clerk for whom an individual Z report has been generated is not
allowed to make registrations in the REG mode. This condition, in which registrations by the clerk are
disallowed, is canceled when his or her sales data is consolidated and reset at the master or when the
sales data is manually cleared. (For the manual clearing operation, see pages 61–62.)
When an X or Z report for the locked clerk is generated again, the COPY mark will be printed in the
report as shown below. (This COPY mark will not appear when the system has a save file.)
Full clerk report sample in the individual clerk file system (master)
• For selecting whether your system should have a save file or not, consult your authorized
SHARP dealer.
• For the setting of the individual resetting data clear at the time of consolidation daily total
resetting, please consult your authorized SHARP dealer.
NOTE
000123  #0162  23/07/2008                   12:46 [0002]
CLERK0001
          Z1
   000001     OK
ALL CLERK
                    COPY
CLK#0001
CLERK0001     
ORDER TL
115.25
CHK/CG
6.80
                    COPY
CLK#0002
CLERK0002     
ORDER TL
18.60
CHK/CG
38.20
Symbol of copy
Symbol of copy
Page of 68
Display